R0K561622S000BE Renesas Electronics America, R0K561622S000BE Datasheet - Page 694

KIT STARTER FOR H8SX/1622

R0K561622S000BE

Manufacturer Part Number
R0K561622S000BE
Description
KIT STARTER FOR H8SX/1622
Manufacturer
Renesas Electronics America
Series
Renesas Starter Kits (RSK)r
Type
MCUr
Datasheets

Specifications of R0K561622S000BE

Contents
Board, Cables, CD, Debugger, Power Supply
Silicon Manufacturer
Renesas
Features
Coding And Debugging, E10A Emulator, RS232 Serial Connection
Kit Contents
Board
Silicon Family Name
H8SX/1622F
Silicon Core Number
R5F61622N50LGV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H8SX/1622
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Section 16 Serial Communication Interface (SCI)
For the direct convention type, logic levels 1 and 0 correspond to states Z and A, respectively, and
data is transferred with LSB-first as the start character, as shown in figure 16.23. Therefore, data
in the start character in the figure is H'3B. When using the direct convention type, write 0 to both
the SDIR and SINV bits in SCMR. Write 0 to the O/E bit in SMR in order to use even parity,
which is prescribed by the smart card standard.
For the inverse convention type, logic levels 1 and 0 correspond to states A and Z, respectively
and data is transferred with MSB-first as the start character, as shown in figure 16.24. Therefore,
data in the start character in the figure is H'3F. When using the inverse convention type, write 1 to
both the SDIR and SINV bits in SCMR. The parity bit is logic level 0 to produce even parity,
which is prescribed by the smart card standard, and corresponds to state Z. Since the SNIV bit of
this LSI only inverts data bits D7 to D0, write 1 to the O/E bit in SMR to invert the parity bit in
both transmission and reception.
16.7.3
Block transfer mode is different from normal smart card interface mode in the following respects.
• Even if a parity error is detected during reception, no error signal is output. Since the PER bit
• During transmission, at least 1 etu is secured as a guard time after the end of the parity bit
• Since the same data is not re-transmitted during transmission, the TEND flag is set 11.5 etu
• Although the ERS flag in block transfer mode displays the error signal status as in normal
Rev. 2.00 Sep. 16, 2009 Page 664 of 1036
REJ09B0414-0200
in SSR is set by error detection, clear the PER bit before receiving the parity bit of the next
frame.
before the start of the next frame.
after transmission start.
smart card interface mode, the flag is always read as 0 because no error signal is transferred.
Block Transfer Mode
(Z)
Figure 16.24 Inverse Convention (SDIR = SINV = O/E = 1)
Ds
A
D7
Z
D6
Z
D5
A
D4
A
D3
A
D2
A
D1
A
D0
A
Dp
Z
(Z) state

Related parts for R0K561622S000BE