R0K561622S000BE Renesas Electronics America, R0K561622S000BE Datasheet - Page 707

KIT STARTER FOR H8SX/1622

R0K561622S000BE

Manufacturer Part Number
R0K561622S000BE
Description
KIT STARTER FOR H8SX/1622
Manufacturer
Renesas Electronics America
Series
Renesas Starter Kits (RSK)r
Type
MCUr
Datasheets

Specifications of R0K561622S000BE

Contents
Board, Cables, CD, Debugger, Power Supply
Silicon Manufacturer
Renesas
Features
Coding And Debugging, E10A Emulator, RS232 Serial Connection
Kit Contents
Board
Silicon Family Name
H8SX/1622F
Silicon Core Number
R5F61622N50LGV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H8SX/1622
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
16.9.7
(1)
Before making the transition to module stop state or software standby mode, stop the transmit
operations (TE = TIE = TEIE = 0). TSR, TDR, and SSR are reset. The states of the output pins
during module stop state or software standby mode depend on the port settings, and the pins
output a high-level signal after mode cancellation. If the transition is made during data
transmission, the data being transmitted will be undefined.
To transmit data in the same transmission mode after mode cancellation, set the TE bit to 1, read
SSR, write to TDR, clear TDRE in this order, and then start transmission. To transmit data in a
different transmission mode, initialize the SCI first.
Figure 16.34 shows a sample flowchart for mode transition during transmission. Figures 16.35 and
16.36 show the port pin states during mode transition.
Before making the transition from the transmission mode using DTC transfer to module stop state
or software standby mode, stop all transmit operations (TE = TIE = TEIE = 0). Setting the TE and
TIE bits to 1 after mode cancellation sets the TXI flag to start transmission using the DTC.
(2)
Before making the transition to module stop state or software standby mode, stop the receive
operations (RE = 0). RSR, RDR, and SSR are reset. If transition is made during data reception, the
data being received will be invalid.
To receive data in the same reception mode after mode cancellation, set the RE bit to 1, and then
start reception. To receive data in a different reception mode, initialize the SCI first.