27330 Parallax Inc, 27330 Datasheet

PROGRAMMER STACHE BASIC STAMP

27330

Manufacturer Part Number
27330
Description
PROGRAMMER STACHE BASIC STAMP
Manufacturer
Parallax Inc
Series
BASIC Stamp® 2p24r
Type
Stache Fieldr
Datasheet

Specifications of 27330

Contents
Programmer
Product
Microcontroller Accessories
For Use With/related Products
BASIC Stamp®
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
http://www.emesystems.com
To download a program from your PC to the Stache…
Start the Parallax Stamp II programming software, and load the program you wish to transfer to the
Stache. You can use either the DOS or the Windows software. If you are running Windows software, be
sure that the proper stamp is targeted (BS2, BS2sx, BS2e or BS2p), and the All option selected for down-
loads under preferences/editor operation). Connect the Stache to your normal programming cable, using
the DB9 gender-changer provided, as shown in the photo. Power the Stache with a good 9-volt battery.
RUN the program just as if you were programming an ordinary BASIC Stamp. The progress bar should
appear on the computer screen, and the LED on the Stache
should flash on and off green as the program is transferred
to the Stache. (If it flashes red, see the error codes below.)
You can now disconnect the programming cable, and you
can disconnect the battery from the Stache. The program
data is stored in non-volatile memory in the Stache.
Special for BS2sx, BS2e & BS2p. These stamps can hold
more than one program in up to 8 program banks. In the
Windows software, the programs can be organized into
projects by use of the $STAMP directive. When you choose RUN, and if ALL is selected under
preferences/editor operation, then all of the programs associated with the project will be downloaded to
the Stache. If you are using the DOS software for the BS2SX, BS2e, or BS2p, you must load and RUN each
program in your project separately, using the ALT-n option to select the target bank before each down-
load. In either case, Windows or DOS, the Stache will store and keep track of all the parts of your project
as one unit.
To upload a program from the Stache to a BASIC Stamp…
action required for the BS2sx, BS2e or BS2p. All of the
programs in the project will be transferred in quick suc-
cession. That's it! Your Stamp is programmed. Unplug
the Stache and detach the battery, or move on to pro-
gram other Stamps.
When you connect the Stache to a good 9 volt battery, the green light will
flash briefly. Plug the Stache into the programming connector on your
Stamp project or carrier board. Refer to the box if you do not have a stan-
dard connector and need to construct an adapter. Be sure the power to your
project is also turned on—the Stache battery does not power your Stamp
project. There must be a
connection (direct or via a
capacitor) from pin 4 of
the DB9 connector to pin
3 of the BASIC Stamp.
The type of program in the Stache must match the type of Stamp to be pro-
grammed, or else you will get an error message.
Press and quickly release the pushbutton on the Stache. The green light
should flash on and off as the program is transferred to the BASIC Stamp,
and then finish up with a longer green flash. (If it flashes red, see the error
codes.) There is no special
Stache Quick Start.
© 2000, 2001, version 1.6, 4-February-2002
Stache to stamp, program upload adapter
long red: out of stache memory
error codes (number of red flashes):
Stache pin 5 of DB9, to pin 4 of the BASIC Stamp
Stache pin 2 of DB9, to pin 1 of the BASIC Stamp
Stache pin 3 of DB9, to pin 2 of the BASIC Stamp
Stache pin 4 of DB9, to pin 3 of the BASIC Stamp
1: check connections and power supplies.
2: no program for the stamp detected.
3: check for loose connections or bad data.
page 1 of 10

Related parts for 27330

27330 Summary of contents

Page 1

To download a program from your PC to the Stache… Start the Parallax Stamp II programming software, and load the program you wish to transfer to the Stache. You can use either the DOS or the Windows software. If you ...

Page 2

New features added with firmware revisions 1.4 to 1.6: Please see page 8. Definitions: • download refers to the process of storing Basic Stamp programs into the Stache by commanding the Parallax editor- to RUN the program. You can use ...

Page 3

Stache memory. (If it flashes red or if the PC gives an error message, see the error codes on page 6) If your program contains a debug command, a ...

Page 4

Using the DOS software: (STAMP2SX.EXE or STAMP2E.EXE or STAMP2P.EXE): Start the program- ming software and load the program you wish to download to the Stache. The program extensions should be .bsx, .bse or .bsp. This will be the first of ...

Page 5

DATA “!1!” as the first data statement in each program associated with project number 1. Project #0 is the same as the default project the one that is uploaded with a single quick click on the pushbutton. It ...

Page 6

... STACHE banks used ** (c)2000 * firmware v1.4 by S.Parkis * ® BASIC Stamp is a registered trademark of Parallax, Inc. Parallax Inc., 599 Menlo Drve, Suite 100, Rocklin CA 95765 tel:888/512-1024 or 916/624-8333 fax:916/624-8333 © 2000, 2001, version 1.6, 4-February-2002 1.01 emesystems.com ** http://www.parallaxinc.com page ...

Page 7

Stache, technical Information and circuit description: The Stache is built around a Scenix SX18AC microcontroller run at 4mhz in the turbo mode. The pushbutton is connect pin ra.3 with a pullup resistor to Vdd. Pushing the button brings ...

Page 8

Revision History of the Stache firmware. The current version of the Stache firmware is 1.6 Please visit Stache firmware appears in the debug window, right after you program a Stamp with a program that has at least one debug command. ...

Page 9

... Fifth St., Berkeley CA 94710 tel:510/848-5725 fax:510/848-5748 http://www.emesystems.com http://www.emesystems.com fax:(510)848-5748 email: stache@emesys.com BASIC Stamp Parallax Inc., 599 Menlo Drve, Suite 100, Rocklin CA 95765 © 2000, 2001, version 1.6, 4-February-2002 ® registered trademark of Parallax, Inc. tel:888/512-1024 or 916/624-8333 fax:916/624-8333 http://www.parallaxinc.com page ...

Page 10

Above: The diagram shows how you might use a Stache to program a stamp project out in the field, or how you might physically send a Stache to someone to do the field programming if you cannot go yourself. Below: ...