70M-IAC5 Grayhill Inc, 70M-IAC5 Datasheet

MODL MINI AC INPUT 5V OUTPUT

70M-IAC5

Manufacturer Part Number
70M-IAC5
Description
MODL MINI AC INPUT 5V OUTPUT
Manufacturer
Grayhill Inc
Series
70r
Type
ACr
Datasheet

Specifications of 70M-IAC5

Turn Off Time
20ms
Turn On Time
20ms
Color
Yellow
Style
Mini
Voltage - Input
90 ~ 140VAC (120VAC Nom)
Current - Input
8mA
Logic Supply Voltage (output)
5VDC (3 ~ 6VDC)
Logic Supply Current (output)
10mA
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Output Current Max
50mA
No. Of Digital Outputs
1
Signal Input Type
90 To 140VAC/DC
Supply Voltage
5VDC
Connection To Host
Board Mount
Current, Input
10 mA
Input
90 to 140 VAC
Input Type
Analog
Input, Range
90 to 140 VAC
Module Type
Input
Number Of Channels
1
Primary Type
Control
Resistance, Input
22 Kiloohms (Nom.)
Special Features
Optical Isolation
Standards
UL, CSA, CE, TUV Certified
Temperature, Operating
-40 to +100 °C
Time, Turn-off
20 ms
Time, Turn-on
20 ms
Voltage, Isolation
4000 VAC
Voltage, Operating
120
Voltage, Supply
5 VDC
Contact Configuration
SPST-NO
No. Of Analog Inputs
1
No. Of Outputs
1
Output Current Min
1mA
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Features
-
Lead Free Status / Rohs Status
RoHS Exempt Product
Other names
GH7026

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
70M-IAC5
Manufacturer:
GHY
Quantity:
50
Part Number:
70M-IAC5 140VAC
Quantity:
5 400
Part Number:
70M-IAC5A 280VAC
Quantity:
5 400
FEATURES
• Transient Protection: Meets the
• UL, CSA, CE, TÜV Certified (TÜV
• Optical Isolation
• OpenLine
• Lifetime Warranty
CIRCUITRY
SPECIFICATIONS: By Package Style
1
2
3
I/O
14
requirements of IEEE 472, “Surge
Withstanding Capability Test”
not available on OpenLine)
Built-in Status LED
Field to logic and channel-to-channel if Grayhill racks are used.
MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec
MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g.
Package Style
Specifications
Output Current Range
Minimum Output Breakdown Voltage
Maximum Turn-On Time
Maximum Turn-Off Time
Isolation Voltage
Vibration
Mechanical Shock
Storage Temp. Range
Operating Temp. Range
Warranty
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
2
®
+
VDC
+VCC
OUTPUT
GROUND
and G5 Modules have
Status LED in G5 modules only.
Standard, Mini, G5
1
3
1
2
3
4
5
AC Input Modules
REGULATING
Rx
CURRENT
HYST. CIRC.
VOLTAGE
INPUT
Units
Vrms
Vdc
mA
mS
mS
°C
°C
TERMINAL
BLOCK #
*
I/O MODULE
PIN #
MIL-STD-202
MIL-STD-202
-40 to +125
-40 to +100
DEVICE
DEVICE
INPUT
INPUT
Std (70-)
Lifetime
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
4000
1-50
50
20
20
1
2
3
4
BASE
RACK
OR
70L-IAC
1
2
3
4
2
, 10-150 Hz.
TYPICAL WIRING FOR MODULE 70
MIL-STD-202
MIL-STD-202
*
Mini (70M-)
-40 to +125
-40 to +100
Separate supplies may also be used.
Lifetime
4000
1-50
FILTER
FILTER
50
20
20
OpenLine
ISOLATION
ISOLATION
OPTICAL
OPTICAL
70G-IAC
MODULE
®
HYSTERESIS
MIL-STD-202
MIL-STD-202
-40 to +125
-40 to +100
G5 (70G-)
Lifetime
HYSTERESIS
A
4000
1-50
50
20
20
70-IAC
B
0Ω
6
7
5
8
9
IEC68-2-27
-40 to +100
Vcc
CH. A STATUS
GND
CH. B STATUS
MODULE ID
OL (70L-)
IEC68-2-6
-40 to +85
Lifetime
70M-IAC
2500
1-50
50
20
20

Related parts for 70M-IAC5

70M-IAC5 Summary of contents

Page 1

... INPUT 1 1 DEVICE FILTER ISOLATION 2 2 INPUT 3 3 DEVICE FILTER * ISOLATION 4 4 TERMINAL BASE OR BLOCK # RACK * Separate supplies may also be used. Std (70-) Mini (70M-) Units mA 1-50 1-50 Vdc Vrms 4000 4000 MIL-STD-202 MIL-STD-202 MIL-STD-202 MIL-STD-202 °C -40 to +125 -40 to +125 °C ...

Page 2

... Module ID Resistance to Logic Ground 1 For input voltages in the range of 15-32 Vac, or 35-60 Vac, see DC input Modules with the suffix. Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois Grayhill Part Number 70M-IAC5 70M-IAC5A 70M-IAC15 70M-IAC15A 70M-IAC24 70-IAC5 70-IAC5A 70-IAC15 Units Vac ...

Related keywords