RM805012 Tyco Electronics, RM805012 Datasheet

RELAY GP DPDT 25A 12VDC PLUGIN

RM805012

Manufacturer Part Number
RM805012
Description
RELAY GP DPDT 25A 12VDC PLUGIN
Manufacturer
Tyco Electronics
Series
RM, SCHRACKr
Datasheet

Specifications of RM805012

Relay Type
General Purpose
Coil Type
Standard
Contact Form
DPDT (2 Form C)
Contact Rating (current)
25A
Switching Voltage
400VAC
Coil Current
108.3mA
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
1.2 VDC
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .250" (6.3mm)
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
25A @ 400VAC
Control On Voltage (max)
9 VDC
Control Off Voltage (min)
1.2 VDC
Coil Voltage Vdc Nom
12V
Contact Current Max
25A
Contact Voltage Ac Nom
400V
Coil Resistance
110ohm
Contact Configuration
DPDT
Contact Rating
25 A
Contact Termination
Bracket
Mounting Style
Quick Connect
Power Consumption
1.3 W
Contact Material
Silver Cadmium Oxide
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
2-1393844-6
PB931

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RM805012
Manufacturer:
PLX
Quantity:
201
Part Number:
RM805012
Manufacturer:
TE/泰科
Quantity:
20 000
n
n
n
n
n
Typical applications
Cleaning equipment, heating and cooling equipment
09-2010, Rev. 0910
www.tycoelectronics.com
© 2010 Tyco Electronics Ltd.
Approvals
VDE REG.-Nr. 40003144, cULus E214025,
approvals for AgNi contacts in preparation
Technical data of approved types on request
Contact Data
Contact arrangement
Rated voltage
Max. switching voltage
Rated current
Limiting making current, 20ms max.
Switching power
Contact material
Min. recommended contact load
Frequency of operation,
Operate/release time max., DC coil
Bounce time max., form A/form B, DC coil
Contact ratings
Type
IEC 61810
RM80
UL 508
RM80
RM8
RM80
RM82
RM82
Mechanical endurance
2 pole 25 A, 2 form C (2 CO) contacts
DC or AC coil
Mechanical indicator
Push-to-test button
Chassis- or DIN-rail mount
with/without load, DC coil
Contact
C (CO)
A/B (NO/NC) 25 A, 240 VAC, 1 phase per pole,
A/B (NO/NC) 25 A, 415 VAC, resistive, AC-Coil 45°C
A/B (NO/NC) 25 A, 415 VAC, resistive, DC-Coil 50°C
A/B (NO/NC) 16 A, 415 VAC, resistive, 70°C
A/B (NO/NC) 240 VAC, 1phase, 2HP, 50°C
Load
25 A, 250 VAC, cosφ=1 35°C
general purpose 40°C
General Purpose Relays
Industrial Relays
Power Relay RM 8
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
AgCdO, AgNi90/10
10x10
24VDC/100mA
2 form C (CO)
960/6000h
15/10ms
400VAC
400VAC
6000VA
4/6ms
6
25A
60A
operations
-1
10x10
10x10
10x10
30x10
Cycles
6x10
6x10
3
3
3
3
3
3
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
Coil Data
Coil voltage range
Operative range, IEC 61810
Coil insulation system according UL
Coil versions, DC coil
Operate voltage, DC coil
Release voltage, DC coil
1) Coil resistance ±12%, 2) Coil resistance ±15%
3) Protection diode PD; standard polarity: +A1 / -A2
All figures are given for coil without pre-energization, at ambient temperature +23°C
STD
006
012
024
048
060
110
221
bipolar
LED
L06
L12
L24
L48
L60
M10
N21
Coil code
0A6
0B2
0C4
0E8
0G0
1B0
2C1
PD
3)
LED+
LA6
LB2
LC4
LE8
LG0
MB0
NC1
PD
3)
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
voltage
Rated
110
220
VDC
75% of rated coil voltage
10% of rated coil voltage
12
24
48
60
V
6
6 to 220VDC
class 130 (B)
6 to 400VAC
Z
resistance
Ω±10%
10000
40000
2
2000
2850
110
475
Coil
32
1)2)
1)
2)
Schrack
Rated coil
F0165-B
power
1.1
1.3
1.2
1.2
1.3
1.2
1.2
W
1

Related parts for RM805012

RM805012 Summary of contents

Page 1

... Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www.tycoelectronics.com together with the ‘Definitions’ section. © 2010 Tyco Electronics Ltd. Coil Data Coil voltage range Operative range, IEC 61810 Coil insulation system according UL Coil versions, DC coil ...

Page 2

... Cover with mounting brackets, 6.3 mm quick connect terminals 2 09-2010, Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www.tycoelectronics.com together with the ‘Definitions’ section. © 2010 Tyco Electronics Ltd. (Continued) Insulation Data Initial dielectric strength between open contacts Release Coil ...

Page 3

... RM839524 RM839730 09-2010, Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www.tycoelectronics.com together with the ‘Definitions’ section. © 2010 Tyco Electronics Ltd. (Continued) Typical product code 3 AgCdO, with test button 7 AgNi90/10, with test button Version ...

Related keywords