G7SA-3A1B-DC24 Omron, G7SA-3A1B-DC24 Datasheet

RELAY SAFETY PCB 3PST-NO/1NC 24V

G7SA-3A1B-DC24

Manufacturer Part Number
G7SA-3A1B-DC24
Description
RELAY SAFETY PCB 3PST-NO/1NC 24V
Manufacturer
Omron
Series
G7SAr
Datasheets

Specifications of G7SA-3A1B-DC24

Relay Type
Safety
Contact Form
4PST (3 Form A, 1 Form B)
Contact Rating (current)
6A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Standard
Coil Current
20.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Socket
Termination Style
Socketable
Circuit
4PST (3 Form A, 1 Form B)
Contact Rating @ Voltage
6A @ 30VDC
Control On Voltage (max)
18 VDC
Control Off Voltage (min)
2.4 VDC
Contact Rating
6 A
Contact Termination
Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G7SA3A1BDC24
Z2943
■ Approved Standards
G7SA
• EN Standards, VDE Approved
■ Ratings
Coil
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of 15%.
Compact, Slim Relays Conforming to EN
Standards
• Relays with forcibly guided contacts (EN50205 Class A,
• Supports the CE marking of machinery (Machinery Directive).
• Helps avoid hazardous machine status when used as part of an
• Four-pole and six-pole Relays are available.
• The Relay’s terminal arrangement simplifies PWB pattern design.
• Reinforced insulation between inputs and outputs.
Ordering Information
Relays with Forcibly Guided Contacts
Sockets
Model Number Structure
■ Model Number Legend
G7SA-@A@B
Rated voltage
24 VDC
Standard
Track-mounting
Back-mounting
EN61810-1 (Electromechanical non-specified time all-or-nothing relays)
EN50205 (Relays with forcibly guided (linked) contacts)
approved by VDE).
interlocking circuit.
Relays with Forcibly Guided Contacts
G7SA
2. Performance characteristics are based on a coil temperature of 23 C.
3. The value given for the maximum voltage is for voltages applied instantaneously to the Relay coil (at an ambient temperature of 23 C)
and not continuously.
Type
1
4 poles: 15 mA
6 poles: 20.8 mA
2
Rated current
Track mounting and screw mounting possible
PCB terminals
Flux-tight
1. NO Contact Poles
2: DPST-NO
3: 3PST-NO
4: 4PST-NO
5: 5PST-NO
Sealing
Type
4 poles: 1,600
6 poles: 1,152
Coil resistance
4 poles
6 poles
2. NC Contact Poles
Poles
75% max. (V)
1: SPST-NC
2: DPST-NC
3: 3PST-NC
Reinforced insulation between some poles of different polarity.
Must-operate
voltage
Relays with Forcibly Guided Contacts
No
Yes
No
3PST-NO, SPST-NC
DPST-NO, DPST-NC
5PST-NO, SPST-NC
4PST-NO, DPST-NC
3PST-NO, 3PST-NC
LED indicator
• UL standard UL508 Industrial Control Devices
• CSA standard CSA C22.2 No. 14 Industrial Control Devices
10% min. (V)
Contacts
Must-release
voltage
4 poles
6 poles
4 poles
6 poles
4 poles
6 poles
24 VDC
Poles
110% (V)
Max. voltage
Rated voltage
---
---
24 VDC
Rated voltage
4 poles: Approx. 360 mW
6 poles: Approx. 500 mW
Power consumption
G7SA
G7SA-3A1B
G7SA-2A2B
G7SA-5A1B
G7SA-4A2B
G7SA-3A3B
P7SA-10F
P7SA-14F
P7SA-10F-ND
P7SA-14F-ND
P7SA-10P
P7SA-14P
Model
Model
G-3

Related parts for G7SA-3A1B-DC24

G7SA-3A1B-DC24 Summary of contents

Page 1

... CSA standard CSA C22.2 No. 14 Industrial Control Devices Must-operate Must-release voltage voltage 75% max. (V) 10% min. (V) Relays with Forcibly Guided Contacts Rated voltage Model 24 VDC G7SA-3A1B G7SA-2A2B G7SA-5A1B G7SA-4A2B G7SA-3A3B Poles Rated voltage Model 4 poles --- P7SA-10F 6 poles P7SA-14F 4 poles 24 VDC P7SA-10F-ND 6 poles ...

Page 2

... C. G-4 Relays with Forcibly Guided Contacts Resistive load 250 VAC VDC 6 A 250 VAC, 125 VDC 6 A Dielectric strength 2,500 VAC for 1 min. between poles max. min. (at 500 VDC Approx Approx G7SA Insulation resistance 1,000 M min. (See note 2.) ...

Page 3

... View) ( 0.1 tolerance) Fourteen, 1.4 dia. Note: 1. Terminals 23-24, 33-34, 53-54, and 63-64 are normally open. Terminals 11-12, 21-22, and 31-32 are normally closed. 2. The colors of the cards inside the Relays are as follows: G7SA-5A1B: Blue, G7SA- 4A2B: White, and G7SA-3A3B: Yellow. ...

Page 4

... View) Two, 4 dia. or M3.5 6 Relays with Forcibly Guided Contacts G7SA-2A2B Mounted This display circuit available only for "-ND" models. Note: Terminals 23-24, 33-34, and 43-44 are normally open. Terminals 11-12 and 21-22 are normally closed. G7SA-4A2B G7SA-3A3B Mounted Mounted ...

Page 5

... Three, 2.6 dia. (for M3 tapping screws) Terminal Arrangement/Internal Connection Diagram (Bottom View) G7SA-5A1B Mounted G7SA-4A2B Mounted G7SA-3A3B Mounted G7SA Mounting Hole Placement (Bottom View) ( 0.1 tolerance) Three, 3.2 dia. (for M3 tapping screws) Ten, 1.1 dia. Note: Terminals 23-24, 33-34, and 43-44 are normally open ...

Page 6

... N·m securely. Wire the terminals correctly with no mistakes in coil polarity, otherwise the G7SA will not operate. Cleaning The G7SA is not of enclosed construction. Therefore, do not wash the G7SA with water or detergent. ■ Forcibly Guided Contacts (from EN50205 contact becomes welded, all NC contacts will maintain a minimum distance of 0 ...

Page 7

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 8

Cat. No. GC SAFETY-3A 07/05-11/06 Specifications subject to change without notice Printed in USA ...

Related keywords