G7SA-3A3B-DC24 Omron, G7SA-3A3B-DC24 Datasheet

no-image

G7SA-3A3B-DC24

Manufacturer Part Number
G7SA-3A3B-DC24
Description
RELAY SAFETY PCB 3PST-NO 3NC
Manufacturer
Omron
Series
G7SAr
Datasheet

Specifications of G7SA-3A3B-DC24

Relay Type
Safety
Contact Form
6PST (3 Form A, 3 Form B)
Contact Rating (current)
6A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Standard
Coil Current
20.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Socket
Termination Style
Socketable
Circuit
6PST (3 Form A, 3 Form B)
Contact Rating @ Voltage
6A @ 30VDC
Control On Voltage (max)
18 VDC
Control Off Voltage (min)
2.4 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G7SA-3A3B-DC24
G7SA3A3BDC24
Q2981357
Z2625
Compact, Slim Relays Conforming to
EN Standards
Model Number Structure
Model Number Legend
1. NO Contact Poles
Ordering Information
Relays with Forcibly Guided Contacts
Sockets
G7SA-@A@B
• Relays with forcibly guided contacts
• Supports the CE marking of machinery (Machinery
• Helps avoid hazardous machine status when used as part of
• Four-pole and six-pole Relays are available.
• The Relay’s terminal arrangement simplifies PWB pattern
• Reinforced insulation between inputs and outputs.
Track-mounting
Back-mounting
Relays with Forcibly Guided Contacts
G7SA
(EN50205 Class A, certified by VDE).
Directive).
an interlocking circuit.
design.
Reinforced insulation between some poles of
different polarity.
2: DPST-NO
3: 3PST-NO
4: 4PST-NO
5: 5PST-NO
Standard
Type
1
2
Track mounting and screw mounting possible
PCB terminals
Flux-tight
Sealing
Type
4 poles
6 poles
Poles
Contact configuration
DPST-NO, DPST-NC
3PST-NO, SPST-NC
5PST-NO, SPST-NC
4PST-NO, DPST-NC
3PST-NO, 3PST-NC
LED indicator
2. NC Contact Poles
1: SPST-NC
2: DPST-NC
3: 3PST-NC
Yes
No
No
Be sure to read the “Safety Precautions” on page 6 and the
“Precautions for All Relays with Forcibly Guided Contacts”.
4 poles
6 poles
4 poles
6 poles
4 poles
6 poles
Poles
Rated voltage
12 VDC
18 VDC
21 VDC
24 VDC
48 VDC
110 VDC
Rated voltage
24 VDC
110 VDC
---
---
CSM_G7SA_DS_E_6_1
G7SA-3A1B
G7SA-2A2B
G7SA-5A1B
G7SA-4A2B
G7SA-3A3B
P7SA-10F
P7SA-14F
P7SA-10F-ND
P7SA-14F-ND
P7SA-10P
P7SA-14P
Model
Model
1

Related parts for G7SA-3A3B-DC24

G7SA-3A3B-DC24 Summary of contents

Page 1

... LED indicator Poles 4 poles No 6 poles 4 poles Yes 6 poles 4 poles No 6 poles CSM_G7SA_DS_E_6_1 Rated voltage Model G7SA-3A1B 12 VDC 18 VDC G7SA-2A2B 21 VDC G7SA-5A1B 24 VDC G7SA-4A2B 48 VDC 110 VDC G7SA-3A3B Rated voltage Model P7SA-10F --- P7SA-14F P7SA-10F-ND 24 VDC 110 VDC P7SA-14F-ND P7SA-10P --- P7SA-14P 1 ...

Page 2

... Resistive load 250 VAC VDC 6 A 250 VAC, 125 VDC 6 A Dielectric strength 2,500 VAC for 1 min. between poles 2 -40 to 60°C (with no icing or condensation) G7SA Max. Power consumption voltage (V) (mW) Approx.360 110% Approx. 420 Max. Power consumption voltage (V) (mW) Approx ...

Page 3

... Note: 1. Terminals 23-24, 33-34, and 43-44 are normally open. Terminals 11-12 and 21-22 are normally closed. 2. The colors of the cards inside the Relays are as follows: G7SA-3A1B: Blue and G7SA-2A2B: White. Printed Circuit Board Design Diagram (Bottom View) (±0.1 tolerance) Fourteen, 1.4 dia. ...

Page 4

... Mounting Hole Placement Diagram (Top View) Two, 4 dia. or M3.5 G7SA G7SA-2A2B Mounted This display circuit available only for "-ND" models. Note: Terminals 23-24, 33-34, and 43-44 are normally open. Terminals 11-12 and 21-22 are normally 14.5 ±0.2 closed. 80 ±0.2 G7SA-4A2B G7SA-3A3B Mounted Mounted ...

Page 5

... G7SA-4A2B Mounted G7SA-3A3B Mounted Forcibly Guided Contacts contact becomes welded, all NC contacts will maintain a minimum distance of 0.5 mm when the coil is not energized. Likewise contact becomes welded, all NO contacts will maintain a minimum distance of 0.5 mm when the coil is energized. G7SA Mounting Hole Placement (Bottom View) (± ...

Page 6

... Tighten each screw of the P7SA-10F/10F-ND/14F/14F- torque of 0.78 to 0.98 N·m. • Wire the terminals correctly with no mistakes in coil polarity, otherwise the G7SA will not operate. Cleaning The G7SA is not of enclosed construction. Therefore, do not wash the G7SA with water or detergent. G7SA 6 ...

Page 7

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords