MY2K-US-AC120

Manufacturer Part NumberMY2K-US-AC120
DescriptionRELAY 120V DPDT LATCHING PLUG IN
ManufacturerOmron
SeriesMYK
MY2K-US-AC120 datasheet
 

Specifications of MY2K-US-AC120

Relay TypeGeneral PurposeContact FormDPDT (2 Form C)
Contact Rating (current)3ASwitching Voltage250VAC, 125VDC - Max
Coil TypeLatching, Dual CoilCoil Current5.6mA
Coil Voltage120VACTurn On Voltage (max)96 VAC
Mounting TypeSocketTermination StyleSocketable
CircuitDPDT (2 Form C)Contact Rating @ Voltage3A @ 220VAC
Control On Voltage (max)96 VACLead Free Status / RoHS StatusLead free / RoHS Compliant
Control Off Voltage (min)-Other namesMY2K-USAC120
MY2KUSAC120
Q1263486
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
10
Page 10
11
12
13
14
15
Page 1/15

Download datasheet (499Kb)Embed
Next
General Purpose Relay
Designed small, 2- and 3-pole types
break 5 A loads and 4-pole type, 3 A load
High reliability, long life
Ultra-high sensitivity with quick response
High vibration/shock resistance
3- and 4-pole types have an arc barrier
UL and CSA approved
Withstands dielectric strength of 2,000 V
Relays with high-capacity, LED indicator,
diode surge suppression, push-to-test
button, or RC circuit are available
Changes due to aging are negligible
because of use of special magnetic mate-
rials, thus ensuring long continuous hold-
ing time
Little change in characteristics such as
contact follow, contact pressure, etc.,
throughout long life
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., MY4- DC6 ).
Contact
Type
Terminal
form
Standard
Plug-in/solder
DPDT
3PDT
4PDT
PCB
DPDT
3PDT
4PDT
Plug-in/solder
4PDT
PCB
4PDT
Plug-in/solder
4PDT
PCB
4PDT
Note: 1. For SEV approved type, order the following: MY4- SV -DC6. (Lloyd's Register approval. See “Approvals” section.)
2. To order connecting sockets and mounting tracks, see “Accessories” section.
3. AgCdO contacts are also available (MY2E, MY3E, MY4E). Contact your OMRON sales representative for details.
Part number
Single contact
Standard
Upper
Lower
bracket
mounting
mounting
Construction
mounting
bracket
bracket
Unsealed
MY2
MY2F
MY2S
MY3
MY3F
MY3S
MY4
MY4F
MY4S
MY2-02
MY3-02
MY4-02
Sealed
MYQ4
MYQ4-02
Hermetically
MY4H
Sealed
MY4H-0
MY
Bifurcated contact
Standard
Upper
Lower
bracket
mounting
mounting
mounting
bracket
bracket
MY2Z
MY2ZF
MY2ZS
MY4Z
MY4ZF
MY4ZS
MY2Z-02
MY2Z-02
MYQ4Z
MYQ4Z-02 —
MY4ZH
MY4ZH-0

MY2K-US-AC120 Summary of contents

  • Page 1

    ... Note: 1. For SEV approved type, order the following: MY4- SV -DC6. (Lloyd's Register approval. See “Approvals” section order connecting sockets and mounting tracks, see “Accessories” section. 3. AgCdO contacts are also available (MY2E, MY3E, MY4E). Contact your OMRON sales representative for details. Part number ...

  • Page 2

    ... MY2N-CR — — MY4N-CR — — MY214 — — MY414 — — MY214N — — MY414N — — Part number MY2K-US MY2K-02-US Relay hold-down clip Standard RC circuit PYC-A1 Y92-H3 MY Bifurcated contact Standard Upper Lower bracket mounting mounting mounting bracket bracket MY2ZN — ...

  • Page 3

    MY Back connecting sockets Solder Wire wrap terminal terminal Relay socket socket DPDT PY08 PY08QN 3PDT PY11 PY11QN 4PDT PY14 PY14QN Note: Types PYP-18, PTP-12 and PTP-10 may be cut to any desired length. PC terminal Relay socket DPDT PY08-02 ...

  • Page 4

    MY ■ COIL DATA Non-latching – AC Rated current (mA) Rated voltage ( 214.10 183 12 106. 53. 25.70 22 100/110 11.70/12.90 10/11 110/120 9.90/10.80 8.40/9.20 200/220 6.20/6.80 5.30/5.80 220/240 4.80/5.30 ...

  • Page 5

    MY ■ CHARACTERISTICS Non-latching Contact resistance Operate time Release time Operating frequency Mechanically Under rated load Insulation resistance Dielectric strength Single contact type Bifurcated contact type Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Ambient temperature Operating Humidity ...

  • Page 6

    MY ■ CHARACTERISTIC DATA Maximum switching capacity – Non-latching MY2, MY3 MY4 Rated operating voltage (V) Electrical service life MY2, MY3 (Resistive load) MY2, MY3 (Inductive load) Rated operating current (A) MY4H MY4Z (Resistive load) Rated operating current (A) MY2-Y(Resistive ...

  • Page 7

    ... MY2 MY■ ■ -02 MY■ ■ F Note: The above dimensioned drawing shows the 4-pole type. The dimensions of the 2- and 3-pole types are identical to the 4-pole type. Electrical service life MY2K(-02)-US (Resistive load) Rated operating current (A) MY3 Mounting holes Mounting holes MY ...

  • Page 8

    ... Note: The above dimensioned drawing shows the 4-pole type. The dimensions of the 2- and 3-pole types are identical the 4-pole type. MYQ4(Z) MY2K-US 8 MY4(Z)H-0 Mounting holes MYQ4(Z)-02 MY2K-02-US MY Terminal arrangement (Bottom view) MY2 MY3 MY4, MYQ4(Z), MY4(Z)H, MY4H-0 Mounting holes (Bottom view) ...

  • Page 9

    MY Unit: mm (inch) ■ ACCESSORIES Track mounted sockets (UL File No. E87929) (CSA Report No. LR46088) PYF08A-E Terminal arrangement/ mounting holes (Top view) PYF14A-E Terminal arrangement/ mounting holes (Top view) Back connecting socket (UL File No. E87929) (CSA Report ...

  • Page 10

    MY Unit: mm (inch) ■ ACCESSORIES (continued) Back connecting socket (UL File No. E87929) (CSA Report No. LR46088) – 4PDT PY14 Terminal arrangement (Bottom view) DPDT 3DPT 4DPT MY■ ■ Note: Value in brackets is for -CR. Mounting holes DPDT ...

  • Page 11

    MY Relay hold-down clip PYC-P2 PY■ ■ for test button self-contained type with PFP-100N/PFP-50N mounting track PFP-100N2 mounting track * This dimension is 14.99 mm (0.59 in) on both ends in the case of PFP-100N, but on one end in ...

  • Page 12

    MY Unit: mm (inch) ■ ACCESSORIES (continued) Socket mounting plates [t=1.52 (.06)] PYP-1 Number of socket specs. Socket needed 1 PY08, PY11, PY11QN, PYP-1 PY14, PY4QN ■ RELAY OPTIONS LED Indicator Specifications and dimensions same as the standard type with ...

  • Page 13

    ... Use the standard MY4 (4PDT) sockets with the terminal arrangements listed below. Terminal arrangement/Internal connections (Bottom view Note resistor for ampere-turn compensation, and is incorporated in the relays rated at 50 VAC or above. 2. Pay attention to the polarity of the set and reset coils, as incorrect connection of positive and negative terminals will result in malfunctioning of the relay. With RC circuit ...

  • Page 14

    ... MY2K-■ ■ DPDT CSA certified type (File No. LR31928) Type Contact form MY■ ■ DPDT 3PDT 4PDT MY2K-■ ■ DPDT LR (Lloyd's Register) approved type (File No. 563KOB-204524) Type Contact form MY■ ■ DPDT 4PDT SEV listed type (File No. D791/63 [2- & 4-pole], D791/91 [3-pole]) ...

  • Page 15

    ... MY OMRON ELECTRONICS, INC. One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC RLY6 9/97 Specifications subject to change without notice. MY OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in the U.S.A. 15 ...