Specifications of MY2K-US-AC120

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
3A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Latching, Dual Coil
Coil Current
5.6mA
Coil Voltage
120VAC
Turn On Voltage (max)
96 VAC
Mounting Type
Socket
Termination Style
Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
3A @ 220VAC
Control On Voltage (max)
96 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Other names
MY2K-USAC120
MY2KUSAC120
Q1263486
4
MY
■ COIL DATA
Non-latching – AC
Non-latching – DC
Latching – AC
Latching – DC
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%, -20% for
Rated
voltage (V)
6
12
24
50
100/110
110/120
200/220
220/240
Rated
voltage (V)
6
12
24
48
100/110
Rated
voltage
(V)
6
12
24
50
120
Rated
voltage
(V)
6
12
24
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23°C (73°F).
4. Because the coil is designed for low power consumption, connect a bleeder (if necessary after confirming the leakage
5. For AC type latching coils, the rated current values are half-wave rectified current values measured with a DC ammeter.
AC rated current, and ±15% for DC rated coil resistance.
current), when the coil is driven by an SCR.
Rated current (mA)
Set coil
50 Hz
146
57
27.40
14
15.80
Rated current (mA)
Set coil
50/60 Hz
230
110
52
Rated current (mA)
50 Hz
214.10
106.50
53.80
25.70
11.70/12.90 10/11
9.90/10.80
6.20/6.80
4.80/5.30
Rated current (mA)
150
75
36.90
18.50
9.10/10
60 Hz
142
56
26.40
13.40
5.60
60 Hz
183
91
46
22
8.40/9.20
5.30/5.80
4.20/4.60
Reset coil
50/60 Hz
68
39
18.60
3.50
3.50
Reset coil
50/60 Hz
100
50
25
Coil
resistance
(Ω)
12.20
46
180
788
3,750
4,430
12,950
18,790
Coil
resistance
(Ω)
40
160
650
2,600
11,000
Coil resistance (Ω)
Set coil
13
72
320
1,400
8,300
Coil resistance (Ω)
Set coil
26
110
470
Coil inductance
(ref. value) (H)
Armature
OFF
0.04
0.17
0.69
3.22
14.54
19.20
54.75
83.50
Coil inductance
(ref. value) (H)
Armature
OFF
0.17
0.73
3.20
10.60
45.60
Reset coil
32
130
550
3,000
3,000
Reset coil
60
235
940
Armature
ON
0.08
0.33
1.30
5.66
24.60
32.10
94.07
136.40
Armature
ON
0.33
1.37
5.72
21.00
86.20
Pick-up
voltage
(% of rated voltage)
80% max.
Pick-up
voltage
(% of rated voltage)
80% max.
Pick-up
voltage
(% of rated voltage)
80% max.
Pick-up
voltage
(% of rated voltage)
80% max.
Dropout
voltage
80% max.
Dropout
voltage
80% max.
Maximum
voltage
110% max. Approx.
Maximum
voltage
110% max. Approx.
Dropout
voltage
30% min.
Dropout
voltage
10% min.
voltage
voltage
(VA, W)
(VA, W)
Maximum
110% max.
Maximum
110% max.
Power consumption
Set coil
0.60 to 0.90
Power consumption
Set coil
1.30
Power
consumption
(VA, W)
Approx.
1.00 to 1.20
Approx.
0.90 to 1.10
Power
consumption
(VA, W)
Approx.
0.90
Reset coil
Approx.
0.20 to 0.50
Reset coil
Approx.
0.06
MY