VF4A-45F11 Tyco Electronics, VF4A-45F11 Datasheet - Page 4

RELAY AUTO 12VDC 40A SPDT W/BKT

VF4A-45F11

Manufacturer Part Number
VF4A-45F11
Description
RELAY AUTO 12VDC 40A SPDT W/BKT
Manufacturer
Tyco Electronics
Series
VF4r
Datasheet

Specifications of VF4A-45F11

Relay Type
Automotive
Contact Form
SPDT (1 Form C)
Contact Rating (current)
40A
Switching Voltage
12VDC
Coil Type
Standard
Coil Current
133.3mA
Coil Voltage
12VDC
Turn On Voltage (max)
7.2 VDC
Turn Off Voltage (min)
1.2 VDC
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .250" (6.3mm)
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
40A @ 12VDC
Control On Voltage (max)
7.2 VDC
Control Off Voltage (min)
1.2 VDC
Coil Voltage Vdc Nom
12V
Coil Resistance
90ohm
Contact Configuration
SPDT
Relay Terminals
Quick Connect
Peak Reflow Compatible (260 C)
No
Terminal Type
Quick Connect
Leaded Process Compatible
Yes
Lead Free Status / RoHS Status
Lead free / RoHS non-compliant
Other names
8-1393298-8
PB527
Contact Data
Contact configuration
Circuit symbol
Rated voltage
Rated current
Limiting continuous current
Contact material
Max. switching voltage/power
Max. switching current
On
Off
Min. recommended load
Voltage drop (initial)
Mechanical endurance (without load)
Electrical endurance
(example of resistive load,
further information on request)
Max. switching rate at nominal load
1)
2)
3)
Load Limit Curve
The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V or 27 V for 24 V load voltages.
For a load current duration of maximum 3 s for a make/break ratio of 1:10.
See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/
2)
1)
3)
NO contact
NC contact
125°C
23°C
85°C
Plug-In Relays
Mini ISO Relays
VF4 A (Standard, Shrouded and Weatherproof)
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Typ. 60 mV, 200 mV max. at 40 A
Typ. 60 mV, 250 mV max. at 30 A
6 operations per minute (0.1 Hz)
1 A at 12 V/0.5 at 24 V
1 Changeover contact/
Load limit curve 1
during transit time (changeover contact)
Load limit curve 2
no stationary arc (make contact)
> 1 x 10
> 1 x 10
See load limit curve
Typ. 10
Silver based
40 A, 13.5 V
(NO contact)
30 A, 13.5 V
(NC contact)
45/120 A
1 Form C
20/14 A
45/60 A
30/40 A
12/17 A
40/60 A
NC/NO
NC/NO
6
12 V
5
5
operations
operations
operations
^
= arc extinguishes
^
= safe shutdown,
Catalog 1308028-2
Revised 3-2008
67

Related parts for VF4A-45F11