VF4A-15H11-S08 Tyco Electronics, VF4A-15H11-S08 Datasheet - Page 4

no-image

VF4A-15H11-S08

Manufacturer Part Number
VF4A-15H11-S08
Description
RELAY AUTO 24V SPDT PLUG-IN
Manufacturer
Tyco Electronics
Series
VF4r
Datasheet

Specifications of VF4A-15H11-S08

Relay Type
Automotive
Contact Form
SPDT (1 Form C)
Contact Rating (current)
40A
Switching Voltage
12VDC
Coil Type
Standard
Coil Current
66.7mA
Coil Voltage
24VDC
Turn On Voltage (max)
14.4 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Socket
Termination Style
Quick Connect - .250" (6.3mm)
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
40A @ 12VDC
Control On Voltage (max)
14.4 VDC
Control Off Voltage (min)
2.4 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
5-1393305-7
Contact Data
Contact configuration
Circuit symbol
Rated voltage
Rated current
Limiting continuous current
Contact material
Max. switching voltage/power
Max. switching current
On
Off
Min. recommended load
Voltage drop (initial)
Mechanical endurance (without load)
Electrical endurance
(example of resistive load,
further information on request)
Max. switching rate at nominal load
1)
2)
3)
Load Limit Curve
The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V or 27 V for 24 V load voltages.
For a load current duration of maximum 3 s for a make/break ratio of 1:10.
See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/
2)
1)
3)
NO contact
NC contact
125°C
23°C
85°C
Plug-In Relays
Mini ISO Relays
VF4 A (Standard, Shrouded and Weatherproof)
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Typ. 60 mV, 200 mV max. at 40 A
Typ. 60 mV, 250 mV max. at 30 A
6 operations per minute (0.1 Hz)
1 A at 12 V/0.5 at 24 V
1 Changeover contact/
Load limit curve 1
during transit time (changeover contact)
Load limit curve 2
no stationary arc (make contact)
> 1 x 10
> 1 x 10
See load limit curve
Typ. 10
Silver based
40 A, 13.5 V
(NO contact)
30 A, 13.5 V
(NC contact)
45/120 A
1 Form C
20/14 A
45/60 A
30/40 A
12/17 A
40/60 A
NC/NO
NC/NO
6
12 V
5
5
operations
operations
operations
^
= arc extinguishes
^
= safe shutdown,
Catalog 1308028-2
Revised 3-2008
67