G6EU-134P-ST-US-DC12 Omron, G6EU-134P-ST-US-DC12 Datasheet

RELAY LOW SIGNAL

G6EU-134P-ST-US-DC12

Manufacturer Part Number
G6EU-134P-ST-US-DC12
Description
RELAY LOW SIGNAL
Manufacturer
Omron
Series
G6Er
Datasheet

Specifications of G6EU-134P-ST-US-DC12

Relay Type
General Purpose
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Type
Latching, Single Coil
Coil Current
16.7mA
Coil Voltage
12VDC
Control On Voltage (max)
8.4 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
1 Form C
Power Consumption
200 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6EU134PSTUSDC12
Subminiature, Sensitive Signal Relay
• Subminiature 7.87 H x 9.91 W x 16 L mm.
• High sensitivity with pick-up coil power of 98 mW.
• Surge withstand voltage meets FCC Part 68 requirements.
• Unique moving loop armature reduces relay size, magnetic
• Bifurcated crossbar contact assures high reliability.
• Single and Dual coil latching versions available.
• Fully sealed construction.
• RoHS Compliant.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6E-134P-ST-US-DC6).
Model Number Legend
Specifications
■ Contact Data
Note: P level:
SPDT
2. Contact Form
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load (See note) 10 ?A, 10 mVDC
1. Relay Function
interference, and contact bounce time.
Low Signal Relay
G6E
G6E
1:
None: Single-side stable
U:
K:
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary
depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions.
1
Double-winding latching
Single-winding latching
SPDT
-
λ
2 3 4 5 6
60
= 0.1 x 10
Contact form
Bifurcated crossbar
–6
/operation
0.40 A at 125 VAC, 2 A at 30 VDC
Ag (Au clad)
3 A
250 VAC, 220 VDC
3 A
50 VA, 60 W
-
7
-
4. Enclosure Ratings
3. Contact Type
8
3: Bifurcated crossbar
4: Fully sealed
DC
Ag (Au-Alloy) contact
Resistive load (p.f. = 1)
Straight
Self-clinching
9
Terminal style
5. Terminals
6. Special Function
G6E-134P-US
G6E-134C-US
P: Straight PCB
C: Curved tail
L: Low sensitivity coil (400 mW)
Standard
0.20 A at 125 VAC, 1 A at 30 VDC
25 VA, 30 W
Model
Inductive load (p.f. = 0.4) (L/R = 7 ms)
Low Signal Relay
G6EU-134P-US
G6EU-134C-US
Single coil latching
9. Rated Coil Voltage
7. Standoff dimension
8. Approved Standards
Blank: 0.3 mm
ST:
US: UL, CSA certified
3, 5, 6, 9, 12, 24, 48 VDC
G6E
G6EK-134P-US
G6EK-134C-US
Dual coil latching
0.64 mm
R
C
89

Related parts for G6EU-134P-ST-US-DC12

G6EU-134P-ST-US-DC12 Summary of contents

Page 1

... Fully sealed Resistive load (p. 0. 125 VAC VDC 25 VA Model Single coil latching Dual coil latching G6EU-134P-US G6EK-134P-US G6EU-134C-US G6EK-134C-US 7. Standoff dimension Blank: 0.3 mm ST: 0. Approved Standards US: UL, CSA certified 9. Rated Coil Voltage 12, 24, 48 VDC Inductive load (p.f. = 0.4) (L ms) G6E ...

Page 2

... Rated Coil voltage current resistance (VDC) (mA) (Ω) 3 133 22.50 5 79. 66. 44.30 203 12 33.30 360 24 16.70 1,440 Standard Single Coil Latching Type (G6EU-134P(-ST)-US, G6EU-134C(-ST)-US) Rated Rated Coil voltage current resistance (VDC) (mA) (Ω) 3 66. 125 6 33.30 180 9 22.20 405 12 16.70 720 24 8 ...

Page 3

... Rated operating current (A) Reset pick-up Maximum Power voltage voltage consumption (mW rated voltage 70% min. 170% max. Approx. 400 at 23°C Ambient Temperature vs. Maximum Coil Voltage G6E-134P-US G6EK-134P-US G6EU-134P-US G6E-134P-US Only at 48VDC Ambient temperature (°C) G6E 91 Low Signal Relay ...

Page 4

... Note: 1. All units are in millimeters unless otherwise indicated. 2. Orientation marks are indicated as follows: Standard coil G6E-134P(L)(-ST)-US 0.6 1.6 G6E-134C(-ST)-US 3.16 2.86 0.6 1.6 Single coil latching G6EU-134P(L)(-ST)-US 0.6 1.6 G6EU-134C(-ST)-US 2.86 3.16 0.6 1.6 G6E 92 Low Signal Relay 10 max. 16 max. (9.9) * (15. max. **0.3 (7. ...

Page 5

Dual coil latching G6EK-134P(L)(-ST)-US 0.6 1.6 G6EK-134C(-ST)-US 2.86 3.16 0.6 1.6 ■ Approvals UL Recognized (File No. E41515) / CSA Certified (File No. LR31928 Ambient Temp. = 40°C Contact form Coil ratings SPDT VDC Note: ...

Page 6

... Distance between terminals: 2.54 × 2 (pitch) max. ■ Hints on Correct Use Single-winding type (G6EU) Example of low-power consumption driver circuit 1. This is an example of a driver circuit that allows Model G6E to function as a normal relay with a normal switching pulse input. 2. The relay is set by an abrupt current charged to capacity C. This ...

Page 7

... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...

Page 8

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...

Related keywords