RELAY SWITCH LATCH 1.5VDC PCB

ASX2101H

Manufacturer Part NumberASX2101H
DescriptionRELAY SWITCH LATCH 1.5VDC PCB
ManufacturerPanasonic Electric Works
SeriesASX
ASX2101H datasheet
 


Specifications of ASX2101H

Relay TypeTelecomCircuitDPDT (2 Form C)
Contact Rating @ Voltage0.01A @ 10VDCCoil TypeLatching, Single Coil
Coil Current23.3mACoil Voltage1.5VDC
Control On Voltage (max)1.2 VDCMounting TypeThrough Hole
Termination StylePC PinLead Free Status / RoHS StatusLead free / RoHS Compliant
Control Off Voltage (min)-Other names255-1870
ASX2101H
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
Page 1/5

Download datasheet (114Kb)Embed
Next
Compliance with RoHS Directive
ORDERING INFORMATION
ASX 2
0
Contact arrangement
2: 2 Form C
Operating function
0: Single side stable
1: 1 coil latching
2: 2 coil latching
Type of operation
0: Standard type (B.B.M.)
Terminal shape
Nil:
Standard PC board terminal
A:
Surface-mount terminal (A type)
Nominal coil voltage (DC)
1H: 1.5V 03: 3V 4H: 4.5V 06: 6V 09: 9V
12: 12V 24: 24V
Packing style
Nil:
Tube packing
X:
Tape and reel packing (picked from 1/3/4/5 pin side)
Z:
Tape and reel packing (picked from 8/9/10/12 pin side)
TYPES
1. Standard PC board terminal
Single side stable
Contact
Nominal coil
arrangement
voltage
1.5V DC
3V DC
4.5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
HIGH SENSIBILITY RELAY
WITH GUARANTEED
LOW LEVEL SWITCHING
CAPACITY
FEATURES
1. High contact reliability over a long
life has been made possible for low
level loads.
Using a low level load (1 mV 10 A to
10 V 10 mA) 10
operations were
7
achieved with a static contact
resistance of Max. 100 m (voltage
drop of 20 mV, 1 mA, 1 kHz) and a
dynamic contact resistance of Max.
1
(Measurement delay 10 ms,
voltage drop of 20 mV, 1 mA, 1 kHz).
2. High sensibility of 50 mW
By using the highly efficient polar
magnetic circuit “seesaw balance
armature mechanism”, a rated power
consumption of 50 mW (for single side
stable type) has been achieved.
1 coil latching
Part No.
Part No.
ASX2001H
ASX2101H
ASX20003
ASX21003
ASX2004H
ASX2104H
ASX20006
ASX21006
ASX20009
ASX21009
ASX20012
ASX21012
ASX20024
ASX21024
SX (ASX)
SX RELAYS (ASX)
3. Low thermal electromotive force
Reducing the heat from the coil
enables a thermal electromotive force
of 3 V or less.
TYPICAL APPLICATIONS
This relay will be used for the low level
load for measuring instruments or others
where a stable contact resistance is
required.
2 coil latching
Part No.
ASX2201H
ASX22003
ASX2204H
ASX22006
ASX22009
ASX22012
ASX22024

ASX2101H Summary of contents

  • Page 1

    ... High sensibility using the highly efficient polar magnetic circuit “seesaw balance armature mechanism”, a rated power consumption (for single side stable type) has been achieved. 1 coil latching Part No. Part No. ASX2001H ASX2101H ASX20003 ASX21003 ASX2004H ASX2104H ASX20006 ASX21006 ASX20009 ASX21009 ASX20012 ASX21012 ...

  • Page 2

    ... Reset coil 46.7mA 46.7mA 23.3mA 23.3mA 15.6mA 15.6mA 11.7mA 11.7mA (Initial) 7.8mA 7.8mA 5.8mA 5.8mA 6.3mA 6.3mA All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 2 coil latching Part No. ASX210A1H ASX220A1H ASX210A03 ASX220A03 ASX210A4H ASX220A4H ASX210A06 ASX220A06 ASX210A09 ASX220A09 ASX210A12 ASX220A12 ASX210A24 ...

  • Page 3

    ... Switching capacity range 10mA 10 A 1mV 10V Contact voltage All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 2 Form C Max. 100 m (By voltage drop [1kHz]) (By nominal switching capacity: No. of operations: 10 Max. 1 (By voltage drop kHz], Measurement delay 10 ms after applying nominal coil voltage) (By nominal switching capacity: No. of operations: 10 ...

  • Page 4

    ... Direction indication (Reset condition) All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Max. Min. Max. Min. 2,000 4 10 mark can be downloaded from: http://panasonic-electric-works.net/ac PC board pattern (Tolerance: 0.1 .004) 2 coil latching 10.16 ...

  • Page 5

    ... All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 2. Automatic insertion To maintain the internal function of the relay, the chucking pressure should not exceed the values below. Chucking pressure in the direction A: 4.9 N {500gf} or less Chucking pressure in the direction B: 9 ...