NF4EB-5V-A Panasonic Electric Works, NF4EB-5V-A Datasheet

RELAY 2A 5VDC AMBER FLATPACK PCB

NF4EB-5V-A

Manufacturer Part Number
NF4EB-5V-A
Description
RELAY 2A 5VDC AMBER FLATPACK PCB
Manufacturer
Panasonic Electric Works
Series
NFr
Datasheet

Specifications of NF4EB-5V-A

Relay Type
General Purpose
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Type
Standard
Coil Current
55.6mA
Coil Voltage
5VDC
Control On Voltage (max)
4 VDC
Control Off Voltage (min)
0.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NF4EB-5V-A
Manufacturer:
PANASONIC
Quantity:
2 912
ds_61014_en_nf: 040804J
SPECIFICATIONS
Contacts
1].
Coil
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
TYPICAL APPLICATIONS
NF relays are widely acceptable in appli-
cations where small size and high sensi-
tivity are required.
Such applications include: Electronic
equipment, Household applications,
1
2
3
4
5
6
7
Arrangement
Initial contact resistance
(By voltage drop 6 V DC 1 A)
Contact material
Rating,
(resistive load)
Expected life
(min. operations)
Nominal operating power, at 25°C
Max. operating power for continuous duty
MBB types available: 2MBB & 4MBB
(See next page for contact positions.)
Measurement at same location as "Initial breakdown voltage" section
Detection current: 10 mA
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection time: 10µs
Half-wave pulse of sine wave: 6ms
Detection time: 10µs
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT in catalog.
1]
Movable contact
Stationary contact
Max. switching power
Max. switching voltage
Max. switching current
Mechanical
Electrical
(Resistive)
1.189
30.2
Max.
Typical
2 A 30 V DC
1 A 30 V DC
0.5 A 30 V DC
2C
4C
20.0
.787
10.8
.425
mm
FLATPACK RELAY
2 Form C, 4 Form C
Alarm systems, Office machines, Com-
munication equipment, Measuring equip-
ment, Remote control systems, General
control circuits, Machine tools, Industrial
machinery, etc.
inch
Approx. 300 mW
Approx. 480 mW
Gold-clad silver
Gold-clad silver
at 40°C
220 V AC, DC
60 W 100 VA
Approx. 1 W
2 × 10
50 mΩ
25 mΩ
2 A
10
10
10
8
6
7
104°F
5
FEATURES
1. Flatpack
2. Long seller
Characteristics (at 25°C 77°F, 50% R.H. seal level)
Max. operating speed
Initial insulation resistance*
Electrostatic
capacitance
Initial
breakdown
voltage*
Operate time*
Release time (without diode)*
(at nominal voltage)
Contact bounce
Shock
resistance
Vibration
resistance
Conditions for operation,
transport and storage*
(Not freezing and condens-
ing at low temperature)
Unit weight
2
3
Contact/Contact
Contact/Coil
Contact/Ground
Between open contacts
Between contact sets
Between live parts and ground
Between contacts and coil
Functional*
Destructive*
Functional*
Destructive
(at nominal voltage)
7
NF-RELAYS
4
6
1
5
3
In de-energized
condition
In energized
condition
In de-energized
condition
In energized
condition
Ambient temp.
Humidity
2C
4C
at double amplitude of 0.5 mm
at double amplitude of 1.6 mm
at double amplitude of 3.3 mm
117.6 m/s
at double amplitude of 2 mm
196 m/s
Max. 15 ms (Approx. 10 ms)
29.4 m/s
Max. 10 ms (Approx. 3 ms)
98 m/s
(perpendicular to contact)
(perpendicular to contact)
1,000 M Ω at 500 V DC
Min. 980 m/s
Approx. 15.5 g
Min. 196 m/s
(In contact direction)
(in contact direction)
Min. 29.4 m/s
Min. 98 m/s
Approx. 14 g
–40 ° C to + 65 ° C
–40
Approx. 1.5 ms
5 to 85%R.H.
Approx. 4 pF
Approx. 7 pF
Approx. 6 pF
2
2
1,000 Vrms
1,000 Vrms
1,000 Vrms
2
750 Vrms
{10 G}10 to 55 Hz
{20 G}, 10 to 55 Hz
2
°
{3 G}, 10 to 55 Hz
F to +149
50 cps
{12 G}10 to 55 Hz
2
2
2
pending
CSA
{10 G}
{100 G}
2
.49 oz
{20 G}
.55 oz
{3 G}
°
F
1

Related parts for NF4EB-5V-A

NF4EB-5V-A Summary of contents

Page 1

... Detection time: 10µ Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT in catalog. TYPICAL APPLICATIONS NF relays are widely acceptable in appli- cations where small size and high sensi- tivity are required. Such applications include: Electronic equipment, Household applications, ds_61014_en_nf: 040804J FLATPACK RELAY FEATURES 1 ...

Page 2

... NF2EB-12V 12 9.6 NF2EB-24V 24 19.2 NF2EB-48V 48 38.4 NF4EB-5V 5 4.0 NF4EB-6V 6 4.8 NF4EB-12V 12 9.6 NF4EB-24V 24 19.2 NF4EB-48V 48 38.4 DIMENSIONS 2 Form C 10.8±0.3 30.2 .425±.012 1.189 0.3 20.6 4-0.8 dia. .012 .811 .031 dia. Stand-off Resin rise max. 0.5 max. .020 N.O. ...

Page 3

... Humidity: 90% 10Ω 5Ω 1Ω 500mΩ Sealed NFEB relay 100mΩ 50mΩ 100 200 1,000 500 2,000 Exposure time, hrs Test result: Amber relays showed a stable spread of contact resis- Ω tance within the initially specifi after 5,000 hours exposure. 3 ...

Related keywords