RSD-12V Panasonic Electric Works, RSD-12V Datasheet
RSD-12V
Specifications of RSD-12V
Available stocks
Related parts for RSD-12V
RSD-12V Summary of contents
Page 1
... Half-wave pulse of sine wave: 6ms; detection time Half-wave pulse of sine wave: 6ms 7 * Detection time Although R relays are rated at 10 G/55 cps. vibration resistance, they will 7 * withstand G/2,000 cps., provided they receive additional support such anchoring to the PC board with epoxy resin Refer to 5. Conditions for operation, transport and storage mentioned in ...
Page 2
... S: Magnetically sealed (Notes) 1. Power types and 1 Form A types are available on request. (Notes) 2. For UL/CSA recognized types, delete “N” at head portion of part No. and add suffix UL/CSA, when ordering. Ex. RSD-12V UL/CSA (Notes) 3. Standard packing Carton: 50 pcs., Case: 500 pcs. TYPES AND COIL DATA ...
Page 3
... SCHEMATIC 1. Single side stable (2, 6: free terminals) Same operation as the conventional magnetic relays. (a) During deenergization, terminals No. 4 (COM) and No. 1 (N.C.) are on “make” Latching type Once energizaed, the COM contact is kept under the same condition without further energizing continuously. 1 coil latching (2, 6: free terminals) (a) When terminals No. 5 (– ...
Page 4
R REFERENCE DATA 1.-(1) Contact reliability Test sample: R-SD-24V 54 pcs. Circuits: (A) Following figure with diode (B) Following figure without diode Start ...
Page 5
Contact sticking resistance TEST CONDITION The purpose of this test was to confirm contact sticking resistance and contact stability against coil ripples. Tested Sample: R-SD-24V, 10 pcs. Test method: Following coil ripples were applied. Test period: 500 hours 24 ...
Page 6
... Tested Sample: R-SD-12V, 5 pcs. Coil applied Ambient atmosphere: 25°C, 60% RH 200 100 Hour APPLICATION HINTS Contact protection circuit When using R relays in inductive load circuits, a contact protection circuit is recommended. Examples: CR Relay contact Inductive load more than ohms circuit 2. impedance somewhat 2. smaller than impedance of r and c. ...
Page 7
... When designing R relay circuits Care should be taken when designing relay circuits since the response of the relay is so fast that bouncing or chattering from conventional relays in the circuit may cause false operation. When using long lead wires When long wires (as long as 100 m or ...
Page 8
... N.O. side even if the transistor or UJT are in OFF condition result, characteristics of relays may be harmed. Design your circuits in principle to make such residual voltage zero. Short circuit prevention between N.C. and N.O. The separation of loads or insertion of a ...