RSD-12V Panasonic Electric Works, RSD-12V Datasheet - Page 6

no-image

RSD-12V

Manufacturer Part Number
RSD-12V
Description
RELAY 12VDC MAGN SEALED PCB
Manufacturer
Panasonic Electric Works
Series
Rr
Datasheet

Specifications of RSD-12V

Relay Type
General Purpose
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Type
Standard
Coil Current
13.5mA
Coil Voltage
12VDC
Control On Voltage (max)
9.3 VDC
Control Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RSD-12V
Manufacturer:
PANASONIC
Quantity:
440
R
12. Thermal electro motive force
Tested Sample: R-SD-12V, 5 pcs.
Coil applied V: 12 V DC
Ambient atmosphere: 25°C, 60% RH
APPLICATION HINTS
Contact protection circuit
When using R relays in inductive load circuits, a contact protection circuit is recommended.
2 coil latching types
A) The circuit at right is recommended
when using one coil for latching and the
other coil for reset.
R relays are sensitive enough to be
operated by the discharge of energy
accumulated in the inner-coil
capacitance. The use of a diode of over
200 V breakdown will prevent
misoperation from this source.
158
Examples:
The following is life data under our HP2 relay load.
(Notes)
1. When inrush current occurs in the capacitor load circuit or incandescent lamp load circuit, reduce it to less than 5 A. Electrical life of “AuCo”
1.
2. When 5 A to 10 A inrush current occurs in the capacitor load circuit or incandescent lamp load circuit, the use of power types is recommended.
1. r = more than 20 to 30 ohms
2. In an AC circuit
2.
2.
contact types is 10,000 operations in a 5 A inrush current circuit.
impedance of L is to be somewhat
smaller than impedance of r and c.
Contact voltage
200
100
100 V DC
100 V DC
200 V DC
12 V DC
24 V DC
24 V DC
6 V DC
2
4
L
: Inductive load
6
CR
r
S
8
Hour
c
Relay contact
10
Contact current
12
L
232 mA
106 mA
54 mA
15 mA
80 mA
20 mA
10 mA
14
16
Can be used for both AC and DC circuits.
Use 500 to 1000 ohms for r and 0.1 F
to 0.2 F 200 V for c in a general 12 to
24 V load circuit.
13. High temperature test
TEST CONDITION
Tested Sample: R-SD-24V, 30 pcs.
Ambient temperature: 80°C
Humidity: less than 50% R.H.
Exposure time: 2,000 hours with relays
deenergized.
TEST RESULT
Contact resistance: Fig. 1
All samples were measured less than
100 m in contact resistance throughout
this test.
In order to maintain the insulation
between the two coils, connection of the
terminal No. 3 and No. 6 or the terminal
No. 2 and No. 5 is recommended, as
shown in the right figure.
Rectifiers should be inserted in this
circuit when the nominal coil voltage of
the R relay is more than 24 V DC.
0.2 F + 1k or diode
0.2 F + 1k or diode
0.1 F + 1k or diode
0.1 F + 1k or diode
0.2 F + 1k
0.1 F + 1k or varistor
0.1 F + 1k
Contact protection circuit
100
80
60
40
20
10
CR
S
Exposure time, hr
100
r
c
1,000 2,000
L
N.C.
N.O.
Max.
Max.
Min.
Operating speed
2 op./s
2 op./s
2 op./s
2 op./s
2 op./s
2 op./s
2 op./s
14. Influence of adjacent mounting
15. Resistive load test
TEST CONDITION
Tested Sample: R-SD-24V, 10 pcs.
Load: 1 A 20 V DC Resistive
Cycle rate: 1.4 cps.
Contact resistance in life test
Type
Magnetically shielded type
Sealed type
500
100
Distance (mm)
50
20
Latching switch Reset switch
For DC circuits only.
1
(inch)
Expected life, min. op.
Diode
2
5
6
S
(0)
5%
0
No. of operations, 10
3 10
3 10
3 10
2 10
3 10
2 10
2 10
2
3
(.197)
5
10%
1%
5
7
7
7
7
7
7
7
L
10
(.394)
N.C.
N.O.
10
6%
0
15
Max.
Max.
Mean value
of N.O.
Mean value
of N.C.
Min.
Min.
6
(.591)
15
2%
0

Related parts for RSD-12V