LCA125STR Clare, LCA125STR Datasheet

RELAY OPTOMOS 170MA SP-NO 6-SMD

LCA125STR

Manufacturer Part Number
LCA125STR
Description
RELAY OPTOMOS 170MA SP-NO 6-SMD
Manufacturer
Clare
Series
LCA, OptoMOS®r
Datasheet

Specifications of LCA125STR

Circuit
SPST-NO (1 Form A)
Output Type
AC, DC
On-state Resistance
16 Ohm
Load Current
170mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 350 V
Mounting Type
Surface Mount
Termination Style
Gull Wing
Package / Case
6-SMD (300 mil)
Load Voltage Rating
300 V
Load Current Rating
170 mA
Mounting Style
SMD/SMT
Relay Type
Single Pole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
CLA247TR
LCA125STR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LCA125STR
Manufacturer:
CPCLAER
Quantity:
20 000
Features
Applications
DS-LCA125-R8
Load Voltage
Load Current
Max R
Small 6 Pin DIP Package
Low Drive Power Requirements (TTL/CMOS
Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
3750V
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Surface Mount and Tape & Reel
Versions Available
Telecommunications
Instrumentation
Medical Equipment-Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hookswitch
Dial Pulsing
Ground Start
Ringer Injection
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
ON
RMS
Input/Output Isolation
LCA125
300
170
16
Units
mA
V
www.clare.com
Description
LCA125 is a 300V, 170mA, 16
tures enhanced peak load current capability with a 300V
peak load voltage. Current limiting version is available.
(“L” suffix)
Approvals
Ordering Information
Pin Configuration
LCA125/LCA125L Pinout
AC/DC Configuration
Do Not Use
LCA125
LCA125S
LCA125STR
Part #
+ Control
– Control
UL Recognized: File Number E76270
CSA Certified: File Number LR 43639-10
BSI Certified to:
BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
BS EN 41003:1993
Certificate #: 7344
1
2
3
Normally Open (Form A) Devices
Switching Characteristics of
Description
6 Pin DIP (50/Tube)
6 Pin Surface Mount (50/Tube)
6 Pin Surface Mount (1000/Reel)
6
5
4
Single Pole OptoMOS
Load
Do Not Use
Load
LCA125/125L Pinout
DC Only Configuration
Do Not Use
+ Control
– Control
1-Form-A relay. It fea-
1
2
3
LCA125
®
6
5
4
Relay
+ Load
– Load
1

Related parts for LCA125STR

LCA125STR Summary of contents

Page 1

... BS EN 60950:1992 (BS7002:1992) • Certificate #: 7344 • 41003:1993 Certificate #: 7344 Ordering Information Part # Description LCA125 6 Pin DIP (50/Tube) LCA125S 6 Pin Surface Mount (50/Tube) LCA125STR 6 Pin Surface Mount (1000/Reel) Pin Configuration LCA125/LCA125L Pinout AC/DC Configuration Control 2 5 – Control Not Use Switching Characteristics of Normally Open (Form A) Devices www ...

Page 2

... Conditions Symbol Min - 10ms =170mA =300mA =300V LEAK I =5mA, V =10V =5mA, v =10V OFF 50V; f=1MHz C - OUT I =170mA 0.4 I =5mA 3750 I/O www.clare.com Typ Max Units - 300 V - 170 mA - 300 mA - 400 µ - 0 1.2 1 µ RMS Rev. 8 ...

Page 3

... Current = 170mADC) 3.0 2.5 5mA 2.0 1.5 10mA 1.0 20mA 0.5 0 100 -40 - Temperature ( C) www.clare.com LCA125 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 302.5 311.5 320.5 338.5 338.5 347.5 Blocking Voltage (V) LCA125 Typical Turn-On Time (N=50 Ambient Temperature = 25 C) (Load Current = 170mADC; I ...

Page 4

... Temperature ( C) LCA125 Energy Rating Curve 1.2 1.0 0.8 0.6 0.4 0 100 s 1ms 10ms 100ms 1s 10s 100s Time www.clare.com LCA125 Typical Turn-Off vs. LED Forward Current (Load Current = 170mADC) 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0. LED Forward Current (mA) ...

Page 5

... MAX. (.016) 7.493 .102 (.295 .004) 4.877 (.192) Top Cover .050R TYP. 11.989 Tape (.472 User Direction of Feed www.clare.com PC Board Pattern (Top View) 2.540 .127 6-.800 DIA. (.100 .005) (6-.031 DIA.) 7.620 6.350 .127 (.300 (.250 .005) 5.080 ...

Page 6

... The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body other applications intended to sup- port or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice ...