Specifications of G3NA-275B-UTU AC100-240

Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Load Current
75A
Voltage - Input
100 ~ 240VAC
Voltage - Load
19 ~ 264 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Control Voltage Range
100 VAC to 240 VAC
Load Current Rating
75 A
Contact Form
1 Form A
Relay Type
General Purpose Hockey Puck
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3NA275BUTUAC100240
Z2068
New Models with 75-A and 90-A Output
Join the Previous Models with 5- to 50-A
Output.
• AC Output Relays with 75-A and 90-A output added.
• All models feature a uniform mounting pitch.
• Built-in varistor effectively absorbs external surges.
• Operation indicator enables monitoring operation.
• Protective cover for greater safety.
• Standard models certified by UL and CSA and -UTU mod-
Ordering Information
To Order: Select the part number and add the desired rated input voltage, (e.g., G3NA-240B-100 to 120 VAC)
.
Phototriac
Photocoupler
Phototriac
Photocoupler
Phototriac
Photocoupler
els by VDE (TÜV).
Solid State Relay
G3NA
(Table continued on next page.)
Isolation
Yes
Zero cross
function
Yes
Indicator
10 A at 24 to 240 VAC*
20 A at 24 to 240 VAC*
5 A at 24 to 240 VAC*
(19 to 264 VAC)
(19 to 264 VAC)
(19 to 264 VAC)
25 A at 24 to 240 VAC*
(19 to 264 VAC)
25 A at 200 to 480 VAC*
(180 to 528 VAC)
(applicable output load)
Rated output load
Solid State Relay
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 240 VAC
Rated input voltage
G3NA
G3NA-205B
G3NA-210B
G3NA-220B
G3NA-225B
G3NA-425B
Model
451

Related parts for G3NA-275B-UTU AC100-240

G3NA-275B-UTU AC100-240 Summary of contents

Page 1

... Protective cover for greater safety. • Standard models certified by UL and CSA and -UTU mod- els by VDE (TÜV). Ordering Information To Order: Select the part number and add the desired rated input voltage, (e.g., G3NA-240B-100 to 120 VAC) . Isolation Zero cross function ...

Page 2

... G3NA-450B G3NA-275B-UTU, G3NA-290B-UTU, G3NA-475B-UTU, G3NA-490B-UTU Mounting Track and Accessories Mounting bracket for G3NA-240B. Changes pitch (2.21 in.) from 47.5 mm (1.73 in.), the same pitch as G3N-240B. DIN Rail Track (1.64 feet) length; use with Y92B-N❏❏❏ heat sinks DIN Rail Track (3.28 feet) length; use with Y92B-N❏❏❏ heat sinks ...

Page 3

... Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC, the input impedance is measured at 120 VAC). 2. With constant current input circuit system, the impedance for the G3NA-2❏❏B-UTU is 15mA max. 3. Refer to the “Characteristic Data” for further details. ...

Page 4

... VAC at 200 VDC 20 mA max. at 400 VAC 2 (approx. 100G) Approx Approx Approx (2.5 oz.) (2.8 oz.) (2.5 oz.) G3NA- G3NA- G3NA- G3NA- 275B- 290B- 475B- 490B- UTU UTU UTU UTU 1/2 of load power source cycle + 1 ms max. 3/2 of load power source cycle + 1 ms max. ...

Page 5

... Without heat sink 0 − − 100 Ambient temperature (°C) Solid State Relay G3NA-220B/420B With standard heat sink (Y92B-A100 or Y92B- N100) or aluminum plate measuring 200 mm x 200 With iron plate measuring 100 x 100 x t0 Without heat sink Ambient temperature (°C) G3NA-450B 60 50 ...

Page 6

... Energized time (ms) Temperature Characteristics (for Must Operate Voltage Heat Sink Area vs. and Must Release Load Current Voltage) G3NA-220B G3NA-2❏❏B AC input 3,000 40 2,000 Ambient temperature 80°C 1,000 20 700 500 300 0 200 100 70 −20 ...

Page 7

... Dimensions ■ Relays Note: All units are in millimeters unless otherwise indicated. G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B 11.9 58 max. 47.5 44 G3NA-240B, G3NA-440B 58 min. 47.5 44 G3NA-D210B Note: The load can be connected to either the positive or negative side. 11.9 58 max. 47.5 44 G3NA-275B-UTU, G3NA-475B-UTU, G3NA-290B-UTU, G3NA-490B-UTU 58 max ...

Page 8

... R99-12 FOR G3NA (for the G3NA and G3NE) Two, M4 mounting holes for the G3NA 30 Two, M4 mounting 44 holes for the G3NE Mounting Bracket R99-11 (for the G3NA-240B, G3NA-440B) Use Mounting Bracket R99-11 so that the G3NA-240B/-440B can be mounted with the same pitch as that of the G3N-240B 12 Heat Sinks Y92B-N50 Heat Sink (for the G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-410B, G3NE-210T(L)) For surface mounting, a 30% derating of the load current is required (from the Load Current vs ...

Page 9

... Y92B-P250NF Heat Sink (for the G3NA-275B-UTU, G3NA-475B-UTU, G3NA-290B-UTU, G3NA-490B-UTU) The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions. Observe the precautions given in Mounting Method under Precautions for Correct Use. ...

Page 10

... The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions. G3NA 460 Solid State Relay Mounting Holes 190.5 max. 70 max. Y92B-A250 Heat Sink (for the G3NA-440B) Three, M4 holes 47.6 47.6 R2.2 50±0.1 50±0.1 56±0.5 56±0.5 150 max ...

Page 11

... VDC 100 to 240 VAC G3NA-420B G3NA-425B G3NA-440B G3NA-450B G3NA-D210B Note: 1. When used with the proper OMRON heat sink part number or an appropriately dimensioned equivalent. 2. The rated values approved by each of the safety standards (e.g., UL, CSA, and TÜV) may be different from the performance characteristics individually defined in this catalog ...

Page 12

... Do not use the G3NA if the heat sink fins are bent, e.g., as the result of dropping the G3NA. Heat dissipation characteristics will be reduced, possibly causing G3NA failure. ...

Page 13

... Operating and Storage Locations Do not use or store the G3NA in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. • Do not use or store in locations subject to direct sunlight. • Do not use in locations subject to ambient temperatures outside the range –20 to 60°C. ...

Page 14

... First, temporarily mount the Heat Sink with the bottom two screws and then attach the top two screws with the mounting bracket sand- wiched between the Heat Sink and mounting surface. Finally, tighten all four screws. G3NA 464 Solid State Relay Ratings and Characteristics of High- ...

Page 15

... Connect the varistor to both sides of the G3NA output terminals. • Do not use an input line that is longer than 3 m. Loss Time The loss time will increase when the G3NA is used at a low applied voltage or current. Be sure that this does not cause any problems. Loss time ...

Page 16

... When transporting the G3NA, observe the following points. Not doing so may result in damage, malfunction, or deterioration of perfor- mance characteristics. • Do not drop the G3NA or subject it to severe vibration or shock. • Do not transport the G3NA wet. • Do not transport the G3NA under high temperatures or humidity. ...

Page 17

... Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. Solid State Relay G3NA ...

Page 18

... E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 06/09 Cat. No. X301-E-1 G3NA Solid State Relay 2. Programmable Products. Seller shall not be responsible for the user's pro- gramming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a war- ranty ...