LBA127S Clare, LBA127S Datasheet

no-image

LBA127S

Manufacturer Part Number
LBA127S
Description
RELAY OPTOMOS 200MA DP 8-SMD
Manufacturer
Clare
Series
LBA, OptoMOS®r
Datasheet

Specifications of LBA127S

Circuit
DPST-NO/NC (1 Form A and B)
Output Type
AC, DC
On-state Resistance
10 Ohm
Load Current
200mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 250 V
Mounting Type
Surface Mount
Termination Style
Gull Wing
Package / Case
8-SMD (300 mil)
Load Voltage Rating
250 V
Load Current Rating
200 mA
Mounting Style
SMD/SMT
Relay Type
Dual Pole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
DS-LBA127-R10
Features
Blocking Voltage
Load Current
Max R
Parameter
Telecommunications
Instrumentation
Medical Equipment-Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
Pb
Small 8-Pin DIP Package
Low Drive Power Requirements (TTL/CMOS
Compatible)
High Reliability
Arc-Free With No Snubbing Circuits
3750V
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Surface Mount, Tape & Reel Version Available
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hook Switch
Dial Pulsing
Ground Start
Ringing Injection
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
ON
rms
2002/95/EC
Input/Output Isolation
RoHS
e
3
Ratings
250
200
10
Units
mA
V
Ω
www.clare.com
P
Description
LBA127 is 250V, 200mA, 10Ω independent
1-Form-A and 1-Form-B relays. It features a superior
combination of low on-resistance and enhanced peak
load current handling capabilities.
Approvals
Ordering Information
Pin Configuration
Part #
LBA127
LBA127P
LBA127PTR
LBA127S
LBA127STR
UL Recognized Component: File # E76270
CSA Certified Component: Certificate # 1172007
Certified to:
Switching Characteristics of
+ Control - Normally Closed
– Control - Normally Closed
+ Control - Normally Open
– Control - Normally Open
IEC 60950-1: 2005
EN 60950-1: 2006
TUV Certificate # B 09 07 49410 004
Control
I
LOAD
Dual Single-Pole OptoMOS
(Form A) Devices
Normally Open
+
90%
t
ON
Description
8-Pin DIP (50/Tube)
8-Pin Flatpack (50/Tube)
8-Pin Flatpack (1000/Reel)
8-Pin Surface Mount (50/Tube)
8-Pin Surface Mount (1000/Reel)
10%
+
AC/DC Configuration
1
2
3
4
t
OFF
Switching Characteristics of
CONTROL
I
LOAD
(Form B) Devices
Normally Closed
8
7
6
5
Normally Closed Pole
Normally Open Pole
+
10%
LBA127
t
OFF
®
Relay
+
90%
t
ON
1

Related parts for LBA127S

LBA127S Summary of contents

Page 1

... Certified to: IEC 60950-1: 2005 EN 60950-1: 2006 TUV Certificate # 49410 004 Ordering Information Part # LBA127 LBA127P LBA127PTR LBA127S LBA127STR Pin Configuration + Control - Normally Closed – Control - Normally Closed + Control - Normally Open – Control - Normally Open Switching Characteristics of (Form A) Devices Control I LOAD www ...

Page 2

... A 150 mW 800 mW 3750 V rms °C °C Conditions Symbol - 10ms I LPK I =200mA =250V I L LEAK =5mA, V =10V OFF 50V, f=1MHz C OUT I =200mA =5mA = I/O www.clare.com Min Typ Max Units - - 200 400 Ω - 6.8 10 μ 110 - 0.4 0 0.9 1.2 1.4 V μ R10 ...

Page 3

... Temperature (ºC) Energy Rating Curve 1.2 1.0 0.8 0.6 0.4 0.2 0 10μs 100μs 1ms 10ms 100ms 1s 10s Time www.clare.com Typical Blocking Voltage Distribution (N=50, T =25ºC) A (Form-A: I =0mA, Form- 0.60 332 334 336 338 Blocking Voltage (V P Typical Blocking Voltage vs ...

Page 4

... Temperature (ºC) Form-A Typical Turn-On vs. LED Forward Current (I =100mA ) L DC 1.00 0.75 0.50 0. LED Forward Current (mA) 100 www.clare.com Form-A Typical Turn-Off Time =25ºC) (N=50, I =5mA, I =200mA 0.45 0.12 0.13 0.14 0.15 Turn-Off (ms) Form-A Typical Turn-Off vs. Temperature (I =5mA, I ...

Page 5

... Temperature (ºC) Form-B Typical Turn-On vs. LED Forward Current (I =100mA ) L DC 78.5 78.0 77.5 77.0 76.5 76 LED Forward Current (mA) 100 www.clare.com Form-B Typical Turn-Off Time (N=50, I =5mA, I =200mA =25º 0.75 1.25 1.75 2.25 0.13 Turn-Off (ms) Form-B Typical Turn-Off vs. Temperature (I =100mA L DC 3.5 ...

Page 6

... Washing Clare does not recommend ultrasonic cleaning or the use of chlorinated solvents. MECHANICAL DIMENSIONS 7.620 ± 0.254 (0.300 ± 0.010) 9.144 ± 0.508 (0.360 ± 0.020) 3.302 ± 0.051 (0.130 ± ...

Page 7

... Top Cover Tape K = 4.90 0 (0.193 4.20 1 (0.165) NOTE: Tape dimensions not shown comply with JEDEC Standard EIA-481-2 www.clare.com LBA127 Recommended PCB Land Pattern 2.54 (0.10) 8.70 1.55 (0.3425) (0.0610) 0.65 (0.0255) Dimensions W = 16.30 max (0.642 max) ...

Page 8

... The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc ...