G3NA-425B DC5-24 Omron, G3NA-425B DC5-24 Datasheet

RELAY SSR 25A@440VAC ZERO CROSS

G3NA-425B DC5-24

Manufacturer Part Number
G3NA-425B DC5-24
Description
RELAY SSR 25A@440VAC ZERO CROSS
Manufacturer
Omron
Series
G3NAr

Specifications of G3NA-425B DC5-24

Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Load Current
25A
Voltage - Input
5 ~ 24VDC
Voltage - Load
180 ~ 528 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Control Voltage Range
5 VDC to 24 VDC
Load Voltage Rating
400 V to 600 V
Load Current Rating
25 A
Contact Form
1 Form A
Mounting Style
DIN Rail
Relay Type
General Purpose Hockey Puck
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3NA-425B-DC5-24
G3NA425BDC524
Z170
New Models with 75-A and 90-A Output
Currents Join the Previous Models with
5- to 50-A Output Currents.
• AC Output Relays with 75-A and 90-A output currents have
• All models feature the same compact dimensions to provide
• Built-in varistor effectively absorbs external surges.
• Operation indicator enables monitoring operation.
• Protective cover for greater safety.
• Standard models certified by UL and CSA and -UTU models
Ordering Information
To Order: Select the part number and add the desired rated input voltage, (e.g., G3NA-240B- 100 to 120 VAC )
.
898
Phototriac
Photocoupler
Phototriac
Photocoupler
Phototriac
Photocoupler
been added to the G3NA Series. The standard versions of
these models provide certification for international standards
(-UTU).
a uniform mounting pitch.
by VDE (TÜV).
(Table continued on next page.)
Solid State Relay
G3NA
Isolation
Solid State Relay
Yes
Zero cross
function
G3NA
Yes
Indicator
5 A at 24 to 240 VAC*
(19 to 264 VAC)
10 A at 24 to 240 VAC*
(19 to 264 VAC)
20 A at 24 to 240 VAC*
(19 to 264 VAC)
25 A at 24 to 240 VAC*
(19 to 264 VAC)
25 A at 200 to 480 VAC*
(180 to 528 VAC)
(applicable output load)
Rated output load
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 240 VAC
Rated input voltage
G3NA-205B
G3NA-210B
G3NA-220B
G3NA-225B
G3NA-425B
Model

Related parts for G3NA-425B DC5-24

G3NA-425B DC5-24 Summary of contents

Page 1

... Protective cover for greater safety. • Standard models certified by UL and CSA and -UTU models by VDE (TÜV). Ordering Information To Order: Select the part number and add the desired rated input voltage, (e.g., G3NA-240B- 100 to 120 VAC ) . Isolation Zero cross function ...

Page 2

... G3NA-450B G3NA-275B-UTU, G3NA-290B-UTU, G3NA-475B-UTU, G3NA-490B-UTU Mounting Track and Accessories Mounting bracket for G3NA-240B. Changes pitch (2.21 in.) from 47.5 mm (1.73 in.), the same pitch as G3N-240B. DIN Rail Track (1.64 feet) length; use with Y92B-N❏❏❏ heat sinks DIN Rail Track (3.28 feet) length; use with Y92B-N❏❏❏ heat sinks ...

Page 3

... Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC, the input impedance is measured at 120 VAC). 2. With constant current input circuit system, the impedance for the G3NA-2❏❏B-UTU is 15mA max. 3. Refer to the “Characteristic Data” for further details. ...

Page 4

... VDC 20 mA max. at 400 VAC 2 (approx. 100G) Approx Approx Approx (2.5 oz.) (2.8 oz.) (2.5 oz.) G3NA- G3NA- G3NA- G3NA- 275B- 290B- 475B- 490B- UTU UTU UTU UTU 1/2 of load power source cycle + 1 ms max. 3/2 of load power source cycle + 1 ms max. 1/2 of load power source cycle + 1 ms max. ...

Page 5

... Y92B-N150) 20 With iron plate measuring 100 x 100 x t0 Without heat sink −30− 100 Ambient temperature (°C) G3NA-290B-UTU G3NA-490B-UTU 100 90 0.3°C/W with 80 Heat Sink Using the Y92B-P250NF With iron plate measuring 20 100 x 100 x t0 Without heat sink 0 − ...

Page 6

... Energized time (ms) Temperature Characteristics (for Must Operate Voltage and Must Heat Sink Area Release Voltage) vs. Load Current G3NA-220B G3NA-2@@B AC input 3,000 40 2,000 Ambient temperature 80°C 1,000 20 700 500 300 0 200 100 70 − −40 −30 − ...

Page 7

... Dimensions I Relays Note: All units are in millimeters unless otherwise indicated. G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B 58 max. 47.5 44 G3NA-240B, G3NA-440B 58 min. 47.5 44 G3NA-D210B Note: The load can be connected to either the positive or negative side. 58 max. 47.5 44 G3NA-275B-UTU, G3NA-475B-UTU, G3NA-290B-UTU, G3NA-490B-UTU 58 max. 47.5 44 G3NA ...

Page 8

... Heat Sinks Y92B-N50 Heat Sink (for the G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-410B, G3NE-210T(L)) For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs). The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions ...

Page 9

... Y92B-P250NF Heat Sink (for the G3NA-275B-UTU, G3NA-475B-UTU, G3NA-290B-UTU, G3NA-490B-UTU) (The Y92B-P250NF is scheduled for release on May 1, 2004.) The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions. ...

Page 10

... For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs). The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions. Mounting Holes 190.5 max. 70 max. Y92B-A250 Heat Sink (for the G3NA-440B) Three, M4 holes 47.6 47.6 R2.2 50±0.1 50±0.1 56± ...

Page 11

... VDC 100 to 240 VAC G3NA-420B G3NA-425B G3NA-440B G3NA-450B G3NA-D210B Note: 1. When used with the proper OMRON heat sink part number or an appropriately dimensioned equivalent. 2. The rated values approved by each of the safety standards (e.g., UL, CSA, and TUV) may be different from the performance character- istics individually defined in this catalog ...

Page 12

... Do not use the G3NA if the heat sink fins are bent, e.g., as the result of dropping the G3NA. Heat dissipation characteristics will be reduced, possibly causing G3NA failure. ...

Page 13

... Operating and Storage Locations Do not use or store the G3NA in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. • Do not use or store in locations subject to direct sunlight. • Do not use in locations subject to ambient temperatures outside the range –20 to 60°C. ...

Page 14

... MΩ min. (at 500 VDC) between power sup- ply connections and non-charged metal part 2,000 VAC for 1 min Thermostat: 1,500 VAC for 1 min Between power supply connections and non- charged metal part −30 to 70°C (with no icing) −40 to 85°C (with no icing) 25% to 85% G3NA 911 Solid State Relay ...

Page 15

... Connect the varistor to both sides of the G3NA output terminals. • Do not use an input line that is longer than 3 m. Loss Time The loss time will increase when the G3NA is used at a low applied voltage or current. Be sure that this does not cause any problems. Loss time ...

Page 16

... G3NA from abnormal vibration, do not install the G3NA in locations or by means that will subject it to vibration from other devices, such as motors. 4. Solvents Do not allow the G3NA or the resin portion of the Fan’s thermostat to come in contact with solvents, such as thinners or gasoline. Doing so will dissolve the markings on the G3NA. 5. Oil Do not allow the G3NA terminal cover to come in contact with oil ...

Page 17

... Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronic Components LLC ("Seller"). Seller hereby objects to any terms or conditions proposed in Buyer's purchase order or other documents which are inconsistent with addition to, these Terms ...

Page 18

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...

Related keywords