S3013A Crydom Co., S3013A Datasheet

RELAY SSR AC OUT 1CH 3.0A PCB

S3013A

Manufacturer Part Number
S3013A
Description
RELAY SSR AC OUT 1CH 3.0A PCB
Manufacturer
Crydom Co.
Datasheet

Specifications of S3013A

Control Voltage Type
DC
Input Voltage
3.5VDC To 8VDC
Contact Configuration
SPST-NO
Load Current
3A
Load Voltage Range
20Vrms To 140Vrms
Switching Mode
Zero Cross
Relay Terminals
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Package / Case
-
Mounting Type
-
Voltage - Input
-
Termination Style
-
Output Type
-
Circuit
-
On-state Resistance
-
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Dielectric and insulation resistance are measured between input and output
3) Off-State dv/dt test method per EIA/NARM standard RS-443,
Series 3
PRODUCT SELECTION
Control Voltage
3.5-8 VDC
3.5-8 VDC
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum Load Current [Arms]
Minimum Load Current [Arms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Minimum Power Factor (with Maximum Load)
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Maximum Turn-On Voltage
Minimum Turn-Off Voltage
Nominal Input Impedance
Typical Input Current @ 5 VDC
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)(2)
Minimum Insulation Resistance (@ 500 V DC)(2)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
GENERAL NOTES
• Output rated at 3A @ 20-280 VAC
• DC control
• Zero-crossing (resistive loads) output
• Compact design ideal for replacing electromechanical relays
Thermally conductive
-30 to 125 °C
0.6 oz (0.8g)
-30 to 80°C
4000 Vrms
3.5-8 VDC
10
1/2 Cycle
1/2 Cycle
200 Ohm
3.5 VDC
1.0 VDC
S312
20-140
20 mA
8.0 pF
Epoxy
0.15
9
600
200
1.5
0.5
55
1
3
Ohm
120 VAC
S3012A
S312
S3012A
20-140
0.15
600
201
1.5
0.5
55
4
3
S322
40-280
0.15
600
200
1.5
0.5
55
1
3
240 VAC
S3022A
S322
S3022A
40-280
0.15
600
200
1.5
0.5
55
4
3

Related parts for S3013A

S3013A Summary of contents

Page 1

... Dielectric and insulation resistance are measured between input and output 3) Off-State dv/dt test method per EIA/NARM standard RS-443, • Output rated 20-280 VAC • DC control • Zero-crossing (resistive loads) output • Compact design ideal for replacing electromechanical relays 120 VAC S312 S3012A S312 ...