LBA126P Clare, LBA126P Datasheet

no-image

LBA126P

Manufacturer Part Number
LBA126P
Description
RELAY OPTOMOS 170MA DP 8FLTPK
Manufacturer
Clare
Series
LBA, OptoMOS®r
Datasheet

Specifications of LBA126P

Circuit
DPST-NO/NC (1 Form A and B)
Output Type
AC, DC
On-state Resistance
15 Ohm
Load Current
170mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 250 V
Mounting Type
Surface Mount
Termination Style
Gull Wing
Package / Case
8-Flatpack
Load Voltage Rating
250 V
Load Current Rating
170 mA
Relay Type
Dual Pole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
Applications
DS-LBA126-R3
Load Voltage
Load Current
Max R
Small 8 Pin DIP Package
Low Drive Power Requirements (TTL/CMOS
Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
3750V
FCC Compatible
VDE Compatible
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Surface Mount and Tape & Reel Versions Available
Telecommunications
Instrumentation
Medical Equipment-Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hookswitch
Dial Pulsing
Ground Start
Ringer Injection
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
ON
RMS
Input/Output Isolation
LBA126
250
170
15
Units
mA
V
www.clare.com
Description
LBA126 is 250V, 170mA, 15 independent 1-Form-A and
1-Form-B relays. It features lower on-resistance with
enhanced peak load current handling capabilities.
Approvals
Ordering Information
Pin Configuration
Part #
LBA126
LBA126P
LBA126PTR
LBA126S
LBA126STR
UL Recognized: File Number E76270
CSA Certified: File Number LR 43639-10
BSI Certified to:
BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
BS EN 41003:1993
Certificate #: 7344
Normally Open (Form A) Devices
CONTROL
LOAD
Switching Characteristics of
LBA126 Pinout
AC/DC Configuration
+ Control - Normally Open
– Control - Normally Open
+ Control - Normally Closed
– Control - Normally Closed
10%
+
+
10ms
90%
T
ON
Description
8 Pin DIP (50/Tube)
8 Pin Flatpack (50/Tube)
8 Pin Flatpack (1000/Reel)
8 Pin Surface Mount (50/Tube)
8 Pin Surface Mount (50/Reel)
DUAL POLE OptoMOS® Relay
T
OFF
10%
+
1
2
3
4
Normally Closed (Form B) Devices
CONTROL
Switching Characteristics of
8
7
6
5
Normally Closed Pole
Normally Open Pole
+
90%
+
10ms
10%
T
OFF
LBA126
+
90%
T
ON
1

Related parts for LBA126P

LBA126P Summary of contents

Page 1

... BS EN 41003:1993 Certificate #: 7344 Ordering Information Part # Description LBA126 8 Pin DIP (50/Tube) LBA126P 8 Pin Flatpack (50/Tube) LBA126PTR 8 Pin Flatpack (1000/Reel) LBA126S 8 Pin Surface Mount (50/Tube) LBA126STR 8 Pin Surface Mount (50/Reel) Pin Configuration LBA126 Pinout AC/DC Configuration + Control - Normally Closed – Control - Normally Closed + Control - Normally Open – ...

Page 2

... Conditions Symbol Min - 10ms I - LPK I =170mA =250V LEAK I =5mA, V =10V =5mA, V =10V OFF 50V; f=1MHz C - OUT =170mA 0.4 I =5mA 3750 I/O www.clare.com Typ Max Units - 250 V 170 µ 0 1.2 1 µ RMS Rev. 3 ...

Page 3

... Typical Turn-On Time (N=50 Ambient Temperature = 25 C) (Load Current = 170mADC 5mADC 2.125 0.30 0.42 0.54 0.66 0.78 0.90 Turn-On (ms) www.clare.com LBA126 - Form B Typical On-Resistance Distribution (N=50 Ambient Temperature = 25 C) (Load Current = 170mADC 10.4 10.8 11.2 11.6 12.0 12.4 On-Resistance ( ) LBA126 - Form A ...

Page 4

... Temperature ( C) LBA126 - Form B Typical Turn-Off vs. Temperature (Load Current = 170mADC) 2.5 2.0 1.5 1.0 5mA 0 100 -40 - Temperature ( C) www.clare.com LBA126 - Form B Typical Load Current vs. Temperature 250 200 150 100 50 0 100 120 -40 - 100 Temperature ( C) LBA126 - Form A Typical Blocking Voltage vs. Temperature 350 345 340 ...

Page 5

... Temperature (Load Current = 170mADC) 3.000 2.500 2.000 1.500 1.000 0.500 0 100 -40 - 100 Temperature ( C) www.clare.com LBA126 LBA126 - Form B Typical Turn-On vs. LED Forward Current (Load Current = 170mADC) 0.634 0.632 0.630 0.628 0.626 0.624 0.622 LED Forward Current (mA) LBA126 - Form A Typical On-Resistance vs. Temperature (Load Current = 170mADC; I ...

Page 6

... Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 6 PERFORMANCE DATA* LBA126 - Form B Energy Rating Curve I = 5mADC F 1.2 1.0 0.8 0.6 0.4 0 100 s 1ms -1.0 -0.5 0 0.5 1.0 1.5 2.0 Load Voltage (V) www.clare.com LBA126 10ms 100ms 1s 10s 100s Time Rev. 3 ...

Page 7

... LBA126 PC Board Pattern (Top View) 2.540 .127 (.100 .005) 8.763 .127 (.345 .005) 1.193 (.047) .787 (.031) PC Board Pattern (Top View) 2.540 ...

Page 8

... MAX. (.016) 7.493 .102 (.295 .004) 4.877 (.192) Top Cover .050R TYP. 11.989 Tape (.472 .004) User Direction of Feed www.clare.com .102 3.987 .102 .004) (.157 .004) 16.002 .305 1 8 (.630 .012) 10.287 (.405) 10.287 .102 1.549 .102 ( ...

Page 9

... The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body other applications intended to sup- port or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice ...