H3CR-F8-300 AC100-240 Omron, H3CR-F8-300 AC100-240 Datasheet

RELAY REPEAT CYCLE ANALOG 300HRS

H3CR-F8-300 AC100-240

Manufacturer Part Number
H3CR-F8-300 AC100-240
Description
RELAY REPEAT CYCLE ANALOG 300HRS
Manufacturer
Omron
Series
H3CR-Fr
Datasheet

Specifications of H3CR-F8-300 AC100-240

Mounting Type
Socket
Relay Type
Integrated
Function
Repeat Cycle
Circuit
DPDT (2 Form C)
Delay Time
1.2 Sec ~ 300 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Time Range
1.2 Sec. To 300 Hr.
Supply Voltage Ac, Min
100VAC
No. Of Timing Functions
2
Body Material
52F4140
No. Of Pins
8
Supply Voltage Ac, Max
240VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-F8-300-AC100240
H3CRF8300AC100240
Z2384
DIN 48 × 48-mm Twin Timers
• Wide power supply ranges of 100 to 240 VAC and 48 to
• ON- and OFF-times can be set independently and so
• Fourteen time ranges from 0.05 s to 30 h or from 1.2 s to 300 h
• Models with a flicker ON start or flicker OFF start are available.
• Easy sequence checks through instantaneous outputs for a
• Length, when panel-mounted with a Socket, of 80 mm or less.
• 11-pin and 8-pin models are available.
Model Number Structure
■ Model Number Legend
Ordering Information
■ List of Models
1. Classification
F:
2. Configuration
None: 11-pin socket
8:
Note: Specify both the model number and supply voltage when ordering.
Flicker OFF
start
Flicker ON start 100 to 240 VAC
H3CR - F @ @ - @ @
125 VDC respectively.
combinations of long ON- or OFF-time and short OFF- or ON-
time settings are possible.
depending on the model to be used.
zero set value at any time range.
Solid-state Twin Timers
H3CR-F
Operating
modes
Example: H3CR-F 100-240AC
Twin timers
8-pin socket
1 2
100 to 240 VAC
24 VAC/DC
12 VDC
48 to 125 VDC
24 VAC/DC
12 VDC
48 to 125 VDC
http://www.ia.omron.com/
3
voltage
Supply
4
5
H3CR-F 100-240AC
H3CR-F 24AC/DC
H3CR-F 12DC
H3CR-F 48-125DC
H3CR-FN 100-240AC
H3CR-FN 24AC/DC
H3CR-FN 12DC
H3CR-FN 48-125DC
3. Twin Timer Mode
None: Flicker OFF start
N:
4. Time Range
None: 0.05 s to 30 h models
300:
11-pin models
Supply voltage
Flicker ON start
1.2 s to 300 h models
0.05 s to 30 h models
H3CR-F8 100-240AC
H3CR-F8 24AC/DC
H3CR-F8 12DC
H3CR-F8 48-125DC
H3CR-F8N 100-240AC
H3CR-F8N 24AC/DC
H3CR-F8N 12DC
H3CR-F8N 48-125DC
8-pin models
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
5. Supply Voltage
100-240AC: 100 to 240 VAC
24AC/DC:
12DC:
48-125DC: 48 to 125 VDC
H3CR-F-300 100-240AC
H3CR-F-300 24AC/DC
H3CR-F-300 12DC
H3CR-F-300 48-125DC
H3CR-FN-300 100-240AC
H3CR-FN-300 24AC/DC
H3CR-FN-300 12DC
H3CR-FN-300 48-125DC
11-pin models
24 VAC/VDC
12 VDC
1.2 s to 300 h models
H3CR-F8-300 100-240AC
H3CR-F8-300 24AC/DC
H3CR-F8-300 12DC
H3CR-F8-300 48-125DC
H3CR-F8N-300 100-240AC
H3CR-F8N-300 24AC/DC
H3CR-F8N-300 12DC
H3CR-F8N-300 48-125DC
8-pin models
1

Related parts for H3CR-F8-300 AC100-240

H3CR-F8-300 AC100-240 Summary of contents

Page 1

... Models with a flicker ON start or flicker OFF start are available. • Easy sequence checks through instantaneous outputs for a zero set value at any time range. • Length, when panel-mounted with a Socket less. • 11-pin and 8-pin models are available. Model Number Structure ■ Model Number Legend H3CR - Classification 3. Twin Timer Mode ...

Page 2

... H3CR-F8 H3CR-FN Flicker ON start 8-pin 11-pin ×10 s (10 sec) min (min) 1 0. 120 1 300 ×10 min (10 min) h (hrs) 1 0. 120 1 300 (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F Models H3CR-F8N 8-pin h (hrs) ×10 h (10 hrs) 1 120 30 to 300 2 ...

Page 3

... EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4- contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level 3) IEC61000-4- power-line (level I/O signal-line (level 4) IEC61000-4- line to line (level line to ground (level 3) (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F 3 ...

Page 4

... OFF indicator detection circuit Indicator circuit ROM RAM Clock One-chip microcomputer H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals. (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F Output circuit Time range/unit selectors ...

Page 5

... OFF-time setting knob (with green pointer) For OFF-time setting ON-time unit display window ON-time unit selector (select one from sec min, and hrs, or from min, hrs, and 10 h) (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F 0.1 s min OFF OFF 0.1 s min. ...

Page 6

... R1.3 17 dia dia. R1.3 Dimensions with Back Connecting Socket P3G-08/P3GA-11 81.5 17.4 80 H3CR-F8 H3CR-F8N 90.0 H3CR-F H3CR-FN P3GA-11 Y92F-30 (When * Y92A-48G 2.3 P2CF-08 mounted) P2CF-08-E (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F 66.6 52.3 0.7 6 44.8 × 44.8 11 pins 66 ...

Page 7

... Solid-state Star-delta Timers H3CR-G DIN 48 × 48-mm Star-delta Timer • A wide star-time range (up to 120 seconds) and star-delta transfer time range (up to 0.5 seconds). Model Number Structure ■ Model Number Legend H3CR - Classification G: Star-delta timer 2. Configuration 8: 8-pin socket Ordering Information ■ List of Models ...

Page 8

... P2CF-08-E P3G-08 P3G-08 with Y92A-48G (See note 1) Y92S-27 Y92S-28 Y92P-48GL Y92P-48GB Y92P-48GM Y92H-1 Y92H-2 H3CR-G8L Star-delta timer with instantaneous output Time-limit: Instantaneous: SPST-NO (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-G Models H3CR-G8EL SPST-NO (star operation circuit) SPST-NO (delta operation circuit) 8 ...

Page 9

... Immunity Surge: Case color Light Gray (Munsell 5Y7/1) Degree of protection IP40 (panel surface) Weight H3CR-G8L: approx. 110 g; H3CR-G8EL: approx. 130 g Note: Refer to the Life-test Curve. http://www.ia.omron.com/ 85% to 110% of rated supply voltage Minimum power-opening time: 0.5 s 100 to 120 VAC: approx (2 120 VAC 200 to 240 VAC: approx (3 240 VAC Contact output 250 VAC/30 VDC, resistive load (cosφ ...

Page 10

... Star Star-delta Star-delta operation transfer time transfer time time counting oscillation counting circuit circuit circuit (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-G Star operation Output circuit Delta operation Star operation indicator Indicator circuit Delta operation indicator Star operation Output ...

Page 11

... OFF t1 ON OFF ON OFF Lit Not lit Lit Not lit Star-delta transfer time display window (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-G Star Delta operation operation contact contact them as relay terminals. 0.5 s min. t2 Time unit display (sec is fixed) Time setting knob (for setting ...

Page 12

... Time setting ring Panel cover Dimensions with Back Connecting Socket P3G- Y92F-30 * 2.3 (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-G 0.7 44.8 × 44.8 8 pins 92.9 86.4 H3CR- G8@L P3G-08 (When Y92A-48G mounted) 12 ...

Page 13

... Models with forced-reset input are available. • 11-pin and 8-pin models are available. Model Number Structure ■ Model Number Legend Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 1 for availability. H3CR - Classification 3. Input ...

Page 14

... Note the above minimum power ON time is not secured, the H3CR may not operate. Be sure to secure the above minimum power ON time not use the Timer with a repeat period of less than 3 s. Doing so may result in abnormal heating or burning. Refer to Safety Precautions (H3CR-H) on page 8 for details ...

Page 15

... EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: IEC61000-4-4: IEC61000-4-5: (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level power-line (level I/O signal-line (level line to line (level 3) ...

Page 16

... Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ and a maximum current of 0.1 A can be switched if L ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load VDC for H3CR-H8L/-HRL and 100 VDC for H3CR-H8RL (failure level: P). Time range/ ...

Page 17

... With Reset Input (H3CR-HRL) Reset input Power supply Note: Leave terminal 6 open. Do not use them as relay terminals. http://www.ia.omron.com/ With Reset Input (H3CR-H8RL) Reset input Power supply Note: Leave terminal 3 open. Do not use them as relay terminals. (c)Copyright OMRON Corporation 2007 All Rights Reserved. ...

Page 18

... Output (8 − 5) Lit Output indicator Not lit Rt ON Power (See note) OFF 0.05 s min. Reset input Output (1 − 3) Output (1 − 4) Output (11 − 9) Output (11 − 8) Lit Output indicator Not lit (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR 0.05 s min 0.05 s min. 18 ...

Page 19

... Dimensions with Back Connecting Socket P3G-08/P3GA-11 92.9 15 86.4 H3CR-HRL 109.9 H3CR- H8@L P3G-08 Y92F-30 * P2CF-11 2.3 P2CF-11-E (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-H Time setting knob (for setting power OFF-delay time) 78.0 0.7 44.8 × 44.8 8 pins 78 ...

Page 20

... Power Reset input Output required that the output be turned on repeatedly with an interval of shorter than 3 s, consider use of the H3CR-A in mode D (signal OFF-delay). ■ Others If the H3CR-H is dropped or experiences some other kind of shock, because a latching relay is used for output, contacts may be reversed or go into a neutral state ...

Page 21

... Timer uses half-wave rectification. Only a half AC wave is supplied to the proximity sensor, which may cause operation to be unstable.) Applicable Models H3Y, H3YN, H3RN, H3CA-8, RD2P, and H3CR(-A, -A8, -AP, -F, and -G) Countermeasure Wire through a relay and use the relay contacts to turn the power supply ON and OFF ...

Page 22

... Be sure that all terminals are wired correctly. • Always test the output status with a tester before using a Timer with a built-in keep relay (e.g., the H3CR-H and H3DE-H). Shock resulting from dropping the Timer during transport or handling may cause the output contacts to reverse neutral status. ...

Page 23

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...