H3DE-H AC/DC48 S Omron, H3DE-H AC/DC48 S Datasheet

no-image

H3DE-H AC/DC48 S

Manufacturer Part Number
H3DE-H AC/DC48 S
Description
TIMER 22.5MM .1-12S DIN MNT
Manufacturer
Omron
Series
H3DE-Hr
Datasheet

Specifications of H3DE-H AC/DC48 S

Relay Type
Integrated
Function
Off-Delay
Circuit
SPDT (1 Form C)
Delay Time
0.1 Sec ~ 12 Sec
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
48VAC/DC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3DE-HAC/DC48S
H3DEHACDC48S
DIN Track Mounted, Standard 22.5-mm Width Timer Range
• A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H)
• 12-VDC model available for a specific application. (H3DE-M2)
• Nameplate provided for easy timer identification and management.
• Terminal clamp left open when delivered.
• Finger protection terminal block to meet VDE0106/P100.
• Enables easy sequence checks through instantaneous outputs for a zero set value at any time range.
• Incorporates environment-friendly, cadmium-free contacts. (except for H3DE-H)
• High immunity to inverter noise.
• Approved by UL and CSA.
• Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives.
■ Broad Line-up of H3DE Series
Solid-state Timer
H3DE
Standard Timer
H3DE-M
H3DE-S
H3DE-M/S
Solid-state Timer
Common to ALL Timers
H3DE-M/-S......................................................................................................................................
H3DE-F ...........................................................................................................................................
H3DE-G ..........................................................................................................................................
H3DE-H...........................................................................................................................................
Accessories.....................................................................................................................................
Precautions .....................................................................................................................................
Twin Timer
H3DE-F
H3DE-F
Contents
H3DE
Star-delta Timer
H3DE-G
H3DE-G
Power OFF-delay Timer
H3DE-H
12
18
24
30
31
H3DE-H
2
CSM_H3DE_DS_E_3_1
1

Related parts for H3DE-H AC/DC48 S

H3DE-H AC/DC48 S Summary of contents

Page 1

... H3DE DIN Track Mounted, Standard 22.5-mm Width Timer Range • A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H) • 12-VDC model available for a specific application. (H3DE-M2) • Nameplate provided for easy timer identification and management. ...

Page 2

... Contact output: DPDT (time-limit output SPDT and switchable SPDT (time-limit ←→ instantaneous)) Contact output: SPDT (time-limit output SPDT) Note: Specify both the model number and supply voltage when ordering H3DE-M2. Example: H3DE- 230 VAC/DC Supply voltage ■ Accessories (Order Separately) ...

Page 3

... Timer with a solid-state output such as a sensor. 3. The power consumption is for mode A after the Timer counts the time-up time and for the AC input at 50 Hz. The power consumption of the H3DE-M@ includes the input circuit with the B1 and A1 terminals short-circuited. H3DE-M1 ...

Page 4

... IP30 (Terminal block: IP20) Weight 120 g Note: 1. With the H3DE-M@, if the voltage exceeds 26.4 VAC/DC, the following hold at signal OFF for C, D, and G modes: Accuracy of operating time: ±1% ±50 ms max. at 1.2-s range Setting error: ±10% +100/-50 ms max. Signal input time: 100 ms min. ...

Page 5

... H3DE-M1/-M2 No input is available. Outputs are turned ON according to designated out- put mode when preset value is reached. (see note.) H3DE-M/-S Operating mode selector Output circuit Indicator circuit Power-ON Output indicator indicator Operating mode selector Output circuit Indicator circuit Power-ON Output indicator indicator H3DE-S1/-S2 5 ...

Page 6

... DC supply voltage does not require the designation of polarity. 3. The contact symbol for the H3DE is indicated with contact for conventional timers. ■ Input Connections The inputs of the H3DE-M1/-M2 are voltage (voltage imposition or open) inputs. No-contact Input (Connection to PNP output sensor.) Sensor ...

Page 7

... Selection of Operating Mode The H3DE-M/-S can be set to any one of the operating modes Turn the operating mode selector with a screwdriver until the desired operating mode ( B2 for the H3DE-M and for the H3DE-S) appears in the operating mode display win- dow located below the selector. ...

Page 8

... Instantaneous contacts and 26 Instantaneous contacts and 28 Power indicator Note: The start input of the H3DE-M1 or H3DE-M2 model is activated by applying a voltage to B1 and A2 terminals. The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement on page 6) Timing chart t−a t t−a t− ...

Page 9

... Instantaneous contacts and 26 Instantaneous contacts and 28 Power indicator Note: The start input of the H3DE-M1 or H3DE-M2 model is activated by applying a voltage to B1 and A2 terminals. The voltage can be applied by turning on the contact between B1 and A1 (Refer to Terminal Arrangement on page 6). Timing chart t−a t−a t−a t t− ...

Page 10

... Output indicator (orange) (Lit while Timer gives output.) Operating mode selector (select a mode from B2 and G for the H3DE-M1/-M2, from and B2 for the H3DE-S1/S2) Power-on indicator (green) (Lit while the power is on.) Output type selector switch for H3DE-M2/-S2 (default setting is time-limit output) Nameplate for user use ( ...

Page 11

... ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. H3DE-M/-S Terminal block (black) Surface color: Light gray 5Y7/1 (OMRON) Output type selector switch (default setting: Time-limit output) ...

Page 12

... Combinations of long ON- or OFF-time and short OFF- or ON- time setting are possible. • Long time range from 0 for both ON and OFF time settings. Model Number Structure ■ Model Number Legend H3DE - Twin timers Ordering Information ■ List of Models Operating mode Flicker-OFF/Flicker-ON start ■ ...

Page 13

... VAC/DC max. AC: Approx. 3 230 VAC DC: Approx. 0 VDC Contact output 250 VAC with resistive load (cosφ VDC with resistive load (cosf = 1) Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) Operating: 35% to 85% H3DE-F min hrs 0 ...

Page 14

... A at 250 VAC, resistive load at 360 operations/h) EN61812-1 EN55011 Group 1 class B EN55011 Group 1 class B EN61000-3-2 EN61000-3-3 EN61812-1 EN61000-4- contact discharge (level 3) EN61000-4- power port and output port (level 3) EN61000-4- common mode (level 3) H3DE air discharge (level control port with capacitive clamp (level differential mode (level 3) 14 ...

Page 15

... Outputs are turned ON/OFF according to the time set by the ON-and OFF-time setting dial. ■ Terminal Arrangement Note: DC supply voltage does not require the designation of polarity. OFF indicator ON/OFF start selector Indicator circuit ROM RAM Clock One-chip microcomputer (DIN notation H3DE-F Time unit selector Output circuit 15 ...

Page 16

... OFF indicator OFF set time OFF set time OFF ON Power (A and OFF Output relay and 18 OFF (ON indicator) ON Output relay: NC OFF 15 and 16 ON OFF indicator OFF set time OFF set time OFF H3DE-F ON-time setting dial OFF-time setting dial 0.1 s min. 0.1 s min. 16 ...

Page 17

... OFF-time unit selector (select one from s, 10s, min OFF-time unit display window (Front View) ON/OFF Start Selector Switch Settings Setting Operating mode Flicker-ON start Flicker-OFF start (Bottom View) Terminal block (black) Terminal block (black) H3DE-F Surface color: Light gray 5Y7/1 (OMRON) 17 ...

Page 18

... Solid-state Star-delta Timer H3DE-G • A wide star-time range (up to 120 seconds) and star-delta trans- fer time range (up to 0.5 seconds) Model Number Structure ■ Model Number Legend H3DE - Star-delta timer Ordering Information ■ List of Models Supply voltage 24 to 230 VAC/VDC H3DE-G ■ ...

Page 19

... Minimum power-off time: 0 VAC/DC max. AC: Approx (1 230 VAC DC: Approx. 0 VDC Contact output 250 VAC with resistive load (cosφ VDC with resistive load (cosφ Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) Operating: 35% to 85% H3DE-G 19 ...

Page 20

... A at 250 VAC, resistive load at 360 operations/h) EN61812-1 EN55011 Group 1 class B EN55011 Group 1 class B EN61000-3-2 EN61000-3-3 EN61812-1 EN61000-4- contact discharge (level 3) EN61000-4- power port and output port (level 3) EN61000-4- common mode (level 3) H3DE air discharge (level control port with capacitive clamp (level differential mode (level 3) 20 ...

Page 21

... Indicator circuit Star operation indicator --- Star output is turned OFF when the dial set value is reached and delta output is ON after the preset transfer time elapses (DIN notation H3DE-G Star operation Output circuit Delta operation Delta operation indicator 21 ...

Page 22

... The operation time of the Timer is set with the time setting dial. 0 Star operation time setting Star-delta transfer time 2 Nameplate for user use (20 x 5.4 mm white panel) Time setting dial (for setting star operation time) Star-delta transfer time selector Star-delta transfer time display window (Front View) H3DE-G Time setting dial 22 ...

Page 23

... H3DE-G ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Terminal block (black) Surface color: Light gray 5Y7/1 (OMRON) Terminal block (black) H3DE-G 23 ...

Page 24

... List of Models Supply voltage 100 to 120 VAC 200 to 230 VAC 24 VAC/VDC 48 VAC/VDC Note: Specify both the model number and supply voltage when ordering. Example: H3DE-H 24 VAC/DC S ■ Accessories (Order Separately) Mounting Track 50 cm (l) x 7 (l) x 7 (t) End Plate ...

Page 25

... AC: Approx. 1 230 VAC Contact output 250 VAC with resistive load (cosφ VDC with resistive load (cosφ Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) Operating: 35% to 85% H3DE-H Min. power ON time 0.1 s minimum 0.3 s minimum 25 ...

Page 26

... A at 250 VAC, resistive load at 1,200 operations/h) EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61000-3-2 EN61000-3-3 EN61812-1 EN61000-4- contact discharge (level 3) EN61000-4- power port and output port (level 3) EN61000-4- common mode (level 3) H3DE air discharge (level control port with capacitive clamp (level differential mode (level 3) 26 ...

Page 27

... Timer is turned OFF and the output of the Timer is turned OFF when the preset time elapses. ■ Terminal Arrangement Note: DC supply voltage does not require the designation of polarity. Indicator Time scale circuit selector Oscillation Counting Output circuit circuit circuit (DIN notation H3DE-H 27 ...

Page 28

... Power indicator (green) Lit when the Timer is turned ON. Time Setting The operating time of the Timer is set with the time setting dial. Time setting dial Nameplate for user use (20 x 5.4 mm white panel) Time setting dial (for setting power OFF-delay time) (Front View) H3DE-H 28 ...

Page 29

... H3DE-H ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Terminal block (black) Surface color: Light gray 5Y7/1 (OMRON) Terminal block (black) H3DE-H 29 ...

Page 30

... Accessories (Order Separately) (Common) Note: The following is common for all H3DE models. Note: All units are in millimeters unless otherwise indicated. ■ Dimensions Mounting Track PFP-100N, PFP-50N 7.3±0.15 4 Length 1 m PFP-100N 50 cm PFP-50N 1 m PFP-100N2 End Plate PFP pan head ...

Page 31

... Rail stopper The H3DE can be mounted and dismounted with ease if a distance more is kept between the H3DE and the top surface of other equipment located below the H3DE. ■ Power Supplies The H3DE Series is provided with a transformerless power supply system. An electric shock may be received if the input terminal or the output type selector switch is touched while power is being supplied ...

Page 32

... Wiring (H3DE-H) The H3DE has a high impedance circuit. Therefore, the H3DE may not be reset if the H3DE is influenced by inductive voltage. In order to eliminate any influence of inductive voltage, the wires connected to the H3DE must be as short as possible and should not be installed alongside power lines ...

Page 33

... Operation (H3DE-H) An interval minimum is required to turn on the H3DE after the H3DE is turned off. If the H3DE is turned on and off repeatedly with an interval of shorter than 3 s, the internal parts of the H3DE may deteriorate and the H3DE may malfunction min. Power Output state 1 ...

Page 34

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...