Specifications of CLB-51-70010

Relay Type
Integrated
Function
On-Delay
Circuit
DPDT (2 Form C)
Delay Time
0.1 Sec ~ 10 Sec
Output Type
Mechanical Relay
Contact Rating @ Voltage
10A @ 277VAC
Voltage - Supply
120VAC
Mounting Type
Socket
Termination Style
Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Contact Configuration
DPDT
Nom Input Voltage
120VAC
Delay Time Range
0.1s To 10s
Timing Adjustment
Knob
Relay Mounting
Plug In
Contact Carrying Power
3VA
Time Range
0.1 Sec. To 10 Sec.
Contact Form
DPDT
Contact Rating
10 A at 30 V
Supply Voltage
120 VAC
Timing Range
0.1 s to 10 s
Mode Of Operation
Delay on Operate
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free / RoHS Compliant
Other names
7-1393137-3
PB562
Dimensions are shown for
reference purposes only.
Timing Mode
Delay on operate – Delay period begins when input voltage is applied. At
the end of the delay period, the relay will operate and will not release until
input voltage is removed. Reset occurs when input voltage is reapplied.
CL Timing Specifications
Timing Ranges: From 0.1 to 1.0 sec. through 1.2 to 120 sec.
Timing Adjustment: Fixed, external resistor and knob adjustable.
Tolerance (for AC units add 1/2 cycle 60 Hz.):
Repeatability (for AC units add 1 cycle 60 Hz.):
Release Time: 100 ms, typ.; 150 ms, max.
Recycle Time: 100 ms, typ.; 150 ms, max.
CU Timing Specifications
Timing Ranges: From 1.0 to 10 sec. through 1.0 to 120 sec.
Timing Adjustment: Fixed, external resistor and knob adjustable.
Tolerance (for AC units add 1/2 cycle 60 Hz.):
Repeatability (for AC units add 1 cycle 60 Hz.):
Release Time: 150 ms, typ.; 225 ms, max.
Recycle Time: 150 ms, typ.; 225 ms, max.
Note: On CU types the switching contact may momentarily transfer if the timing interval is
CL Ordering Information – Authorized distributors are more likely to stock boldface items listed below.
INPUT
VOLTAGE
N.O. RELAY
CONTACTS
Voltage
24VAC
24VAC
120VAC
120VAC
120VAC
Knob Adj. Types:–0, +20% of max. specified at high end of timing
Fixed Types:
Res. Adj. Types:
Knob Adj. Types:–0, +20% of max. specified at high end of timing
Fixed Types:
Res. Adj. Types:
interrupted. CL types have no timing cycle interrupt transfer.
ON
OFF
ON
OFF
3 Sec.
0.1 to 10 Sec.
Time
0.1 to 10 Sec.
0.1 to 10 Sec.
0.1 to 10 Sec.
0.3 to 30 Sec.
1.2 to 120 Sec.
30 Sec.
0.1 to 10 Sec.
1.2 to 120 Sec.
5%.
10% at high end of timing range; min. specified, or
5%.
10% at high end of timing range; min. specified, or
TIME
Adjustment
range; min. specified, or less, at low end.
less, at low end.
range; min. specified, or less, at low end.
less, at low end.
Resistor
Resistor
Fixed
Knob
Knob
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Wiring Dia.
1
2
1
1
2
3%.
3%.
Part Number
CLB-51-30010
CLF-42-30010
CLB-51-70010
CLB-51-70030
CLB-51-70120
CLA-41-70003
CLA-41-70030
CLF-41-70010
CLF-42-70010
CLF-41-70120
Catalog 1308242
Issued 3-03
CL -CU
Compact Time Delay Relay
• Delay on operate timing mode
• Fixed, knob or resistor adjustable types
• 10A output relay with DPDT contacts
• Variety of mounting options
• Various models time from 0.1 to 120 sec.
• No timing cycle interrupt transfer (CL only)
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Contact Data @ 25 C
Arrangements: 2 Form C (DPDT).
Material: Silver-cadmium oxide alloy.
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC;
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 100,000 operations, min., at rated load.
Initial Dielectric Strength
Between Open Contacts: 500V rms, 60 Hz.
Between All Other Conductors: 500V rms, 60 Hz.
Input Data @ 25 C
Voltage: 24 & 120VAC and 12 & 24VDC.
Power Requirement: AC Types: Typically less than 3 VA.
Transient Protection: Yes.
Reverse Voltage Protection: Yes.
Input Voltages & Limits @ 25 C
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
Environmental Data
Temperature Range: Storage: -55 C to +85 C.
Mechanical Data
Termination: 0.187 in. (4.75mm) quick-connect.
Enclosure: Yellow plastic case (see outline drawings for various options).
Sockets: Solder, printed circuit and screw terminal sockets available.
Weight: 3.5 oz. (99g) approximately.
Voltage
12VDC
12VDC
12VDC
24VDC
24VDC
41 style models (e.g. CLA-41-70010) have plain case.
42 style models (e.g. CLF-42-70010) have bracket mount case.
45 style models (e.g. CLH-45-30010) have bracket mount case with test button.
51 style models (e.g. CLB-51-30010) have plain case with knob.
File E22575
File LR15734
AC models will operate on 50 or 60 Hz.
Specifications and availability
subject to change.
Voltage
Type
1/3 HP @ 120VAC.
DC
AC
Knob adjustable types have dial scale for reference only.
Time
0.1 to 10 Sec.
10 Sec.
1.2 to 120 Sec.
5 Sec.
0.1 to 10 Sec.
0.3 to 30 Sec.
0.1 to 10 Sec.
series
DC Types: Typically less than 3 W.
Operating: -10 C to +55 C.
Nominal
Voltage
120
12
24
24
Adjustment
Resistor
Resistor
Fixed
Fixed
Knob
Minimum
Voltage
105
20
11
20
Wiring Dia.
1
1
2
1
2
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Maximum
Part Number
CLD-51-20010
CLC-41-20010
CLH-41-20120
CLC-41-30005
CLH-41-30010
CLH-41-30030
CLH-45-30010
Voltage
130
28
13
32
P&B
1231

Related parts for CLB-51-70010

CLB-51-70010 Summary of contents

Page 1

... Knob adjustable types have dial scale for reference only. Sockets: Solder, printed circuit and screw terminal sockets available. Weight: 3.5 oz. (99g) approximately. Part Number Voltage Time 1 CLB-51-30010 12VDC 0 Sec. 2 CLF-42-30010 12VDC 10 Sec. CLB-51-70010 12VDC 1.2 to 120 Sec. 1 CLB-51-70030 24VDC 5 Sec. CLB-51-70120 0 Sec. 1 CLA-41-70003 24VDC 0 Sec. CLA-41-70030 ...

Page 2

... Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. External Resistor Selection Chart See External Resistor Selection Charts at beginning of Time Delay Relay section of this Databook. Dimensions are shown for reference purposes only ...

Related keywords