PM4HA-H-DC12VW Panasonic Electric Works, PM4HA-H-DC12VW Datasheet

no-image

PM4HA-H-DC12VW

Manufacturer Part Number
PM4HA-H-DC12VW
Description
TIMER ANALOG MULTI 12VDC 11PIN
Manufacturer
Panasonic Electric Works
Series
PM4Hr
Datasheet

Specifications of PM4HA-H-DC12VW

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.1 Sec ~ 500 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12VDC
Mounting Type
Socket
Termination Style
11 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1202
’06–’07
Timers/Time Switches/Counters/Hour Meters
Timers/Time Switches/Counters/Hour Meters
ARCT1B274E ’06.10
Matsushita Electric Works, Ltd.

Related parts for PM4HA-H-DC12VW

PM4HA-H-DC12VW Summary of contents

Page 1

Timers/Time Switches/Counters/Hour Meters Timers/Time Switches/Counters/Hour Meters ARCT1B274E ’06.10 ’06–’07 Matsushita Electric Works, Ltd. ...

Page 2

RoHS Directive compatibility information http://www.nais-e.com/ Product types Type /////// PM4S Multi-range Timer A type PM4S Multi-range Timer B type PM4S Power Multi-range Ttimer ON-delay C type PM4S Multi-range Timer D type PM4S Multi-range Timer E type Parts name • The ...

Page 3

PM4S Specifications Item Rated operating voltage Rated frequency Rated power consumption Output rating Rating Operating mode Time range Operating time fluctuation Setting error Time accuracy Note) Voltage error Temperature error Contact arrangement Contact Contact resistance (Initial value) Contact material Mechanical ...

Page 4

... A +0 (48×n–2.5) 0 +.024 A = (1.890×n–.098 time delay contact instantaneous contact Note: Keep 0.1s or more for power off time. PM4S DIN rail terminal block AT8-DF8K (Sold separately) Device installation rail AT8-DLA1 (Sold separately) OFF ...

Page 5

PM4S Precautions during usage 1. Avoid locations subject to flammable or corrosive gases, excessive dust, oil, vibrations, or excessive shocks. 2. Since the main-unit is made of polycarbonate resin, avoid contact with or use in environments containing methyl alcohol, benzene, ...

Page 6

... PM4HA-H-AC240VW 100 to 240V AC Screw terminal PM4HA-H-AC240VSW 11 pins PM4HA-H-DC125VW 48 to 125V DC Screw terminal PM4HA-H-DC125VSW 11 pins PM4HA-H-24VW 24V AC/DC Screw terminal PM4HA-H-24VSW 11 pins PM4HA-H-DC12VW 12V DC Screw terminal PM4HA-H-DC12VSW 11 pins PM4HA-H-AC240V 100 to 240V AC Screw terminal PM4HA-H-AC240VS 11 pins PM4HA-H-DC125V 48 to 125V DC Screw terminal PM4HA-H-DC125VS 11 pins ...

Page 7

PM4H-A/S/M Time range Time unit sec Scale Control time range 10 1.0s to 10s 50s Note: 0 setting is for instantaneous output operation. Specifications Item Rated operating voltage Rated ...

Page 8

Terminal layouts and Wiring diagrams PM4H-A Pin type Screw terminal type • Timed-out 2 Form C • Timed-out 2 Form C Reset input Start input N.C. N.O. Stop input N.C. N.C. 6 N.O. N. ...

Page 9

PM4H-A/S/M Dimensions • PM4H- Screw terminal type (Flush mount) 6.0 .236 48 12.0 1.890 .472 48 1.890 • Panel mount dimensions (with mounting frame) Screw terminal type Rubber gasket ATC 18002 (attached) 48 1.890 1 48 .039 1.890 • Surface ...

Page 10

Operation mode PM4H-A Operation type • If using a time-limit start when the power is turned on, and a reset when the power is turned off, pins should be shorted ahead of time. • Turn the operation mode selector switch ...

Page 11

PM4H-A/S/M Operation type • If using a time-limit start when the power is turned on, and a reset when the power is turned off, pins (screw-tightening pins x and c) should be shorted ahead of time. • ...

Page 12

RoHS Directive compatibility information http://www.nais-e.com/ Specifications Type Item Rated operating voltage Rated frequency Rated power consumption Rating Rated control capacity Operation mode operation control time range - switching time Operation time fluctuation ...

Page 13

PM4H-SD/SDM Time range Time range Operating (s) unit Time range 2 0 100 10 to 100 Product types Operation Type Contact arrangement mode PM4H-SD Relay Timed-out Star ( )-Delta side: ...

Page 14

RoHS Directive compatibility information http://www.nais-e.com/ Specifications Type Item Rated operating voltage Rated frequency Rated power consumption Rating Rated control capacity Operation mode Time range Operation time fluctuation Setting error Time accuracy *1 ...

Page 15

PM4H-F Time range Time range s range type unit Time range 1 0.04s 0. 0.4s to 10s Product types Operation Type Contact arrangement mode Power Relay Timed-out PM4H-F8 OFF-delay 2 Form C (without reset) ...

Page 16

Operation Type Contact arrangement mode Power OFF-delay Relay Timed-out PM4H-F11R (with 2 Form C instantaneous reset) Dimensions • Screw terminal type (Flush mount) 6.0 .236 48 12.0 62.5 1.890 .472 2.461 48 1.890 Protective Time range construction IP65 3 selectable ...

Page 17

PM4H-F Terminal layouts and Wiring diagrams • PM4H-F8 (without reset input) Pin type Time-out 2 Form C N.C. N.C. N.O. N. Operating voltage (–) (+) Screw-tightening pin type The PM4H-F11R should be ...

Page 18

RoHS Directive compatibility information http://www.nais-e.com/ Specifications Type Item Rated operating voltage Rated frequency Rated power consumption Rating Rated control capacity Operation mode Time range Operation time fluctuation Time Setting error accuracy Voltage ...

Page 19

PM4H-W Time range All types of PM4H-W timer have multi-time range. 16 time ranges are selectable 500h (Max. range) is controlled. Time unit sec Scale Control time range 10 1.0s ...

Page 20

PM4H SERIES MODES AND TIME SETTING 1. Operation method 1) Operation mode setting [PM4H-A type] 8 operation modes are selectable with operation mode selector. Turn the operation mode selector with screw driver. Operation mode is shown up through the window ...

Page 21

PRECAUTIONS IN USING THE PM4H SERIES 1. Input connections (PM4H-A type sure not to use terminal as the common terminal of the input signal as shown in Fig. A. Otherwise, the internal circuit of the timer may be ...

Page 22

... When a sensor is connected to the input circuit, install double insulation on the sensor side. (2) In the case of contact input, use dual- insulated relays, etc. 3) The load connected to the output con- tact should have basic insulation. This timer is protected with basic insula- tion and can be double-insulated to meet EN/IEC requirements by using basic insulation on the load ...

Page 23

DIN SIZE TIMERS COMMON OPTIONS Terminal sockets (Unit: mm Type Appearance • DIN rail socket (8-pin) PM4H-S PM4H-M PM4H-SD PM4H-F8 PM4H-F8R 24 .945 PM4H-W LT4H LT4H-L 70 2.756 50 LT4H-W 1.969 QM4H PM4S (8-pin type) ATC180031 • DIN rail socket ...

Page 24

MOUNTING PARTS • Rubber gasket 50.0 1.969 1.0 50.0 .039 1.969 ATC18002 The rubber gasket is enclosed in the PM4H (screw terminal type) and the LT4H series. • Mounting rails (Applicable for 5.5 DIN and IEC standards) .217 AT8-DLA1 Length: ...

Page 25

INSTALLING DIN SIZE TIMER Installations 1. Surface mount 1) For the timers of PM4H and LT4H series, use the pin type timer. With the PM4S and QM4H series, only pin-type timers are available. 2) Put the terminal socket on the ...

Page 26

TIMERS CHART Multiple ON-delay operation LT4H LT4H-L LT4H LT4H-L LT4H-W QM4H S1DX PM4S PM4H-S PMH PM4H-M PM4H-A PM5S-S PM5S-A S1DXM-A/M S1DX S1DXM-A/M S1DX MHP MHP-M 2 OFF-delay Twin Flicker LT4H (Signal) LT4H-W LT4H LT4H-L LT4H-L PM4H-W PM4H-A (Signal) PM4H-A PM4H-F ...

Page 27

TIMERS SELECTOR CHART Power ON-delay Operation mode For time control for short Major uses or long time 1000h 100h 30h 10h 1h Time range 30m 10m Each model has various 5m time ranges. See the 2m 1m product lists before ...

Page 28

... V AC/ AC/ (other models) (other models) T.D. mode: Time delay 2C (Relay output (Transistor out- INST. mode: Time delay 1C type) Timed- put type) Timed- and instantaneous 1C out 1 Form C out 1 Form A (Use MODE switch on front) ±(0.005 ms) ±(0.01 case of power on start in case of power on start ± ...

Page 29

Power ON-delay Power flicker Power One-shot Operation mode Power One-cycle Output with contact CR oscillation counting timer Major uses For highly accurate time setting 1000h 100h 30h 10h 1h Time range 30m 10min 10m Each model has various 5m 3min ...

Page 30

TIMERS SELECTOR CHART Operation mode Major uses Suitable for high accurate, long time uses 1000h 100h 30h 10h 1h Time range 30m 10m Each model has various 5m time ranges. See the 2m 1m product lists before 30s 30s ordering. ...

Page 31

ON-DELAY TIMER BASIC CIRCUIT ( Symbols ) Self-resetting switch Relay NO contact Holding switch Relay NC contact R Relay Timer delay NO contact T Timer Timer delay NC contact L Load Timer instantaneous NO contact Timer in work Timer instantaneous ...

Page 32

... OFF Power supply ( In time delay operation ) ON OFF Output signal ( Time delay contact ) Operating time • Flicker Operation The flicker operation is an operation to repeat output ON/OFF action according to preset ON time and OFF time while a predetermined input is given to the power supply circuit or input circuit. ...

Page 33

Pause Time Error It means the difference between the operating time to a fixed pause time and the operating time to a pause time that varies. The pause time characteristics are the main characteristics of CR timer (timer exploiting ...

Page 34

PRECAUTIONS IN USING THE TIMERS Cautions for circuits 1. Protective circuit for timer contact In the circuit that switches an inductive load, a contact failure may occur at a contact point due to surge or inrush current resulting from that ...

Page 35

If the timer is directly switched with a non-contact element, leak current may flow into the timer and cause it to mal- function. 6. Power off time If the operation voltage for the timer is turned ON after the ...

Page 36

PRECAUTIONS IN USING THE TIMERS 7. Operating environment 1) Use the timer within the ambient tem- perature range from –10°C to +50°C +14°F to +122°F (+55°C +131°F for the LT4H series) and at ambient humidity of 85% RH maximum. 2) ...

Page 37

... PM4H-SD: 1) (1) to (8) have no internal connection, and 2) the input (star) changes PM4HSD- to 1a. PM4H-A With exposed attachment, terminal base ATC180041 should be used. PM4HA- PM4H-S With exposed attachment, terminal base ATC180031 should be used. PM4HS- PM4H-M With exposed attachment, terminal base ATC180031 for F8 type and F8R type ATC180041 for F11R type ...

Page 38

Timers Discontinued models Recommended substitutes PM48W PM4H-W PM48W PM4HW- PMH-M PM4H-M/PM4S PMH-M- PM4HM-/PM4S- CDX Time relay S1DXM-A Timer/ S1DX Timer CDX S1DXM-/S1DX- PDX Timer S1DXM-A Timer/ S1DX Timer PDX S1DXM-/S1DX- VHP digital high-power timer QM4H digital timer VHP QM4H QM48S ...

Page 39

Counters Discontinued models Recommended substitutes MC electromagnetic LC4H counters LC4H MC6 LC4H-L LC48 Relay type: 8-pin LC4H Relay type: 8-pin Tr type: 11-pin Tr type: 11-pin LC4H LC48 LC4H-L LC48W (11-pin) LC4H-W (11-pin) LC48W LC4H-W EM48S (8-pin) LC4H (8-pin) LC4H ...

Page 40

FOREIGN SPECIFICATIONS OVERVIEW 1. International Standards IEC standard International Electrotechnical Commission By promoting international cooperation toward all problems and related issues regarding standardization in the electrical and electronic technology fields, the IEC, a non-governmental organization, was started in October, 1908, ...

Page 41

Pilot Duty One of the specifications in the “UL508 Industrial Control Equipment” regulations at UL (Underwriters Laboratories Inc.), has to do with the grade of contact control capacity by NEMA (National Electrical Manufacturers Association) standards. By obtaining both UL ...

Page 42

FOREIGN SPECIFICATIONS TIMER Recognized by UL Standards Products Name File No. Recognized rating E43149 5A250VAC PM4S PILOT DUTY C300 PM4H-A E122222 5A250VAC PM4H-S PILOT DUTY C300 PM4H-M PM4H-SD PM4H-W E122222 3A250VAC PM4H-F PILOT DUTY C300 E122222 5A250VAC PILOT DUTY C300 ...

Page 43

FOREIGN SPECIFICATIONS Counters UL recognized Product name File No. Approved ratings E122222 5A250V AC LC4H PILOT DUTY C300 LC4H-L LC4H-S 100mA 30V DC E122222 3A250V AC PILOT DUTY C300 LC4H-W 100mA 30V DC E122222 24-240 V AC/DC LC2H 4.5-30 V ...

Page 44

CE MARKINGS OVERVIEW Counter, Hour Meter conforming to EN/IEC standards The Timer, Counter, Hour Meter shown below conform to both EN and IEC standards, and may display the CE markings. Product Product name classification LT4H EN 61000-6-4/EN 61000-6-2 LT4H-L EN ...