A41-43-515 Signal Transformers, A41-43-515 Datasheet

no-image

A41-43-515

Manufacturer Part Number
A41-43-515
Description
XFRMR PWR 115/230V 5V 2A 43VA
Manufacturer
Signal Transformers
Series
A41r
Type
Standardr
Datasheet

Specifications of A41-43-515

Maximum Power
43 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, Center Tap
Mounting Type
Chassis Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Parallel Output Voltage @ Current
-
Series Output Voltage @ Current
-
Note 1: Output capacitors C2 and C4 are required to stabilize regulators. Values can be 1 MFD min. tantalum or 10 MFD min. electrolytic, 20V min.
Note 2: LM-338 is an adjustable regulator and MFR’s specifications (National Semiconductor) should be consulted for values of external components.
Note 3: All IC’s are National Semiconductor types.
Note 4: All bridges are EDI types.
Custom versions available upon request.
All-4-One™ International Triple Output
Transformers - Chassis Mount
For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies Requiring
International Safety Certification
Part Number
A41-25-512
A41-25-515
A41-43-512
A41-43-515
A41-80-512
A41-80-515
www.signaltransformer.com
Note: VDE certified A41 Series transformers with standard length and color lead wires are readily available. Contact Customer Service for more information.
Size
VA
25
25
43
43
80
80
5V @ 1.25A
5V @ 1.25A
5V @ 2A
5V @ 2A
5V @ 3.5A
5V @ 3.5A
Regulator I
DC Output
±12V @ 150mA
±15V @ 130mA
±12V @ 300mA
±15V @ 250mA
±12V @ 600mA
±15V @ 500mA
Regulator II
4.1 KMFD
@15 VDC
@15 VDC
@15 VDC
10 KMFD
8 KMFD
C
1
Triple output transformers with chassis mount capability plus all of the
performance features of our split bobbin A41 series.
• Power - 25 VA to 80 VA
• Dielectric Strength - 4000 Vrms Hipot
• Primaries - Dual primaries (115/230V - 50/60 Hz)
• Secondaries - Dual complementary outputs (5 VDC with ±12 VDC
• Terminals - Solder lug / quick connect type terminals
• Leakage - Current meets UL 60601-1, IEC/EN 60601-1
• Insulation - Class F (155 º C)
• Flammability Rating - Bobbin and shroud material meet UL 94-V0
Agency Certifications
• UL 1446 E66312
• UL recognized to UL 506 / UL 5085-2, File # E63829
• CSA certified to C22.2 No. 66.1, File # 221070
• VDE certified to VDE 0805 / EN 60950 (File # 1448)
General Specifications
or 5 VDC with ±15 VDC)
12
@ 50 VDC
@ 50 VDC
@50 VDC
2.1 KMFD
1.1 KMFD
600 MFD
Toll Free 866-239-5777 • Tel 516-239-5777 • Fax 516-239-7208
sales@signaltransformer.com • techhelp@signaltransformer.com
C
Suggested Components (C
3
©2008 Signal Transformer — Specification subject to change without notice. 07.08
LM-323K-5
LM-323K-5
LM-323K-5
LM-323K-5
LM-338
LM-338
IC1
1
2
2
LM-340K-12
LM-340K-15
LM-340K-12
LM-340K-15
LM-340K-12
LM-340K-15
500 Bayview Avenue, Inwood, NY 11096
IC2
2
2
and C
4
LM-320K-12
LM-320K-15
LM-320K-12
LM-320K-15
LM-320K-12
LM-320K-15
See Note 1)
IC3
3
PE20
PE20
PE20
PE20
PP20
PP20
D1
4
PF20
PF20
PF20
PF20
PF20
PF20
D2
4

Related parts for A41-43-515

A41-43-515 Summary of contents

Page 1

... Regulator I A41-25-512 1.25A A41-25-515 1.25A A41-43-512 A41-43-515 A41-80-512 3.5A A41-80-515 3.5A Note 1: Output capacitors C2 and C4 are required to stabilize regulators. Values can be 1 MFD min. tantalum or 10 MFD min. electrolytic, 20V min. Note 2: LM-338 is an adjustable regulator and MFR’s specifications (National Semiconductor) should be consulted for values of external components. ...

Page 2

... All-4-One™ International Triple Output Transformers - Chassis Mount For 5 VDC and ±12 VDC or ±15 VDC Regulated Power Supplies Requiring International Safety Certification Dimensions Size 2.81 2.14 2.31 25 (71.4) (54.4) (58.7) 3.12 2.14 2.68 43 (79.4) (54.4) (68.2) 2.50 2.53 3.00 80 (63.5) (64.3) (76 ...