TB1-81143 Acme Electric/Amveco/Actown, TB1-81143 Datasheet

TRANSFORMER 100VA 120/240V

TB1-81143

Manufacturer Part Number
TB1-81143
Description
TRANSFORMER 100VA 120/240V
Manufacturer
Acme Electric/Amveco/Actown
Series
TBr
Type
Standardr
Datasheet

Specifications of TB1-81143

Maximum Power
100 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
24 VAC @ 4.17A
Parallel Output Voltage @ Current
12 VAC @ 8.34A
Mounting Type
Chassis Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
5
S S E E C C T T I I O
O N
N
INDUSTRIAL
CONTROL
TRANSFORMERS
Industrial Control Transformers provide
a low and safe control voltage for the
operation of electromagnetic devices, such
as motor starters, contactors, solenoids
and timers . . . or other loads requiring
above average voltage regulation when
actuated.
Selection Steps . . . . . . . . . . . . . . . . . . . . . . . . . . .56
TA Series Open Core & Coil . . . . . . . . . . . . . .57-59
Primary & Secondary Fuse Information . . . . . .58-59
Selection Charts . . . . . . . . . . . . . . . . . . . . . . . .63-68
Wiring Diagrams & Dimensions . . . . . . . . . . . . . . .69
TB Series Open Core & Coil . . . . . . . . . . . . . .60-62
Primary & Secondary Fuse Information . . . . . . . . .61
Selection Charts . . . . . . . . . . . . . . . . . . . . . . . .63-68
Wiring Diagrams & Dimensions . . . . . . . . . . . . . . .70
Harsh Environments Control Transformers . . . .71
AE/CE Series Encapsulated Transformers . . . .72-79
Selection Charts . . . . . . . . . . . . . . . . . . . . . . . . .74-77
FINGER/GUARD
®
Industrial Control Transformer . . . . . . . . . . . . . .80-83
Selection Charts . . . . . . . . . . . . . . . . . . . . . . . . . . .81

Related parts for TB1-81143

TB1-81143 Summary of contents

Page 1

... Wiring Diagrams & Dimensions . . . . . . . . . . . . . . .69 TB Series Open Core & Coil . . . . . . . . . . . . . .60-62 Primary & Secondary Fuse Information . . . . . . . . .61 Selection Charts . . . . . . . . . . . . . . . . . . . . . . . .63-68 Wiring Diagrams & Dimensions . . . . . . . . . . . . . . .70 Harsh Environments Control Transformers . . . .71 AE/CE Series Encapsulated Transformers . . . .72-79 Selection Charts . . . . . . . . . . . . . . . . . . . . . . . . .74-77 FINGER/GUARD ® Industrial Control Transformer . . . . . . . . . . . . . .80-83 Selection Charts . . . . . . . . . . . . . . . . . . . . . . . . . . .81 ...

Page 2

... VA rating of the transformer selected from the manufacturer’s data or the contactor’s data table. 56 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION TABLE 1. Inrush VA Inrush VA @ 20% & 40% Power Factor Nominal 85% Secondary Voltage 90% Secondary Voltage VA Rating 20% P.F. 40% P.F. ...

Page 3

... UL Listed, CSA Certified. ■ Attractive finish, nameplate, and design features ■ enhance the end product. ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION Jumper Link Connections Primary Fuse Kit with Snap-on Secondary Fuse Block Secondary Fuse Clips Integrally Mounted Fuse Blocks Acme Industrial Control Transformers Meet or Exceed UL, CSA, NEMA & ...

Page 4

... Fuse size based on time delay class CC fuses. NOTE: Bold lines indicate changes in the percent of rated current used to calculate fuse sizes in accordance with article 450 of the NEC. 58 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION Figure 1 4. Attach the female quick connect of the jumpers supplied with the fuse kit to male quick connects on the right side of the fuse blocks – ...

Page 5

... Group F series: 230 V parallel: 115 V Group I Series parallel Group J Series: 480 V & 240 V: 240 V & 120 V Group K Series: 240 V: 120 V Exception: 150 VA transformer TA-2-32404 does not have quick connect terminals. ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION PL-112600/601 Fuse Kit Figure 1 Series Connection LUMBERTON, NC 800-334-5214 • ...

Page 6

... Voltage regulation exceeds NEMA requirements. ■ UL Listed and CSA Certified. ■ Meets or exceeds UL, CSA, NEMA, ANSI and ■ OSHA Standards. Ten-year limited warranty. ■ 60 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION APPLICATIONS Motor Starters ■ Contactors ■ Solenoids ■ Timer Circuits ■ ...

Page 7

... VA — 70.0 ① Fuse size based on time delay class CC fuses. NOTE: Bold lines indicate changes in the percent of rated current used to calculate fuse sizes in accordance with article 450 of the NEC. ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION Figure 1 ① 230 V 240 V 277 V ...

Page 8

... Connect the ring terminal of the jumpers supplied to screw terminals X1 and the secondary (X-side) of the transformer. 6. Connect secondary load lines to terminals X2 and F or F2. 62 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION Type Secondary 1/4” x 1-1/4” Fuse Kit 13/32” x 1-1/2” ...

Page 9

... X 240 PRIMARY VOLTS — 12/24 SECONDARY VOLTS — 1Ø, 50/60 Hz CATALOG VA OUTPUT NO. ➁ RATING AMPS TB1-81141 ➁ 50 2.08 4.23 (10.7) TB1-81142 ➁ 75 3.13 4.74 (12.0) TB1-81143 ➁ 100 4.17 4.90 (12.4) TB1-81144 ➁ 150 6.25 4.78 (12.1) TB1-81146 ➁ 250 10.42 5.08 (12.9) TB1-81148 ➁ 350 14 ...

Page 10

... See fusing chart for secondary fuse kits. * ① Secondary Fuse Kit PL-112603 may be substituted for PL-112600 thru PL-112602 when Primary Fuse Kit is used. See page 62. ➁ See chart for integrally mounted fuse block catalog number suffix. 64 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION APPROX. DIMENSIONS INCHES (CM ...

Page 11

... See fusing chart for secondary fuse kits. * ① Secondary Fuse Kit PL-112603 may be substituted for PL-112600 thru PL-112602 when Primary Fuse Kit is used. See page 62. ➁ See chart for integrally mounted fuse block catalog number suffix. ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION APPROX. DIMENSIONS INCHES (CM.) A ...

Page 12

... TA-2-81205 5000 38.46 7.52 (19.1) ① Secondary Fuse Kit PL-112603 may be substituted for PL-112600 thru PL-112602 when Primary Fuse Kit is used. See page 62. ➁ Secondary fuse kit application for 115V only. 66 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION APPROX. DIMENSIONS INCHES (CM 3.75 3 ...

Page 13

... TA-83304 500 41.67 TA-83305 750 62.50 TA-83306 1000 83.33 ① Secondary Fuse Kit PL-112603 may be substituted for PL-112600 thru PL-112602 when Primary Fuse Kit is used. See page 62. ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION OUTPUT VOLTS H1-H5 X1-X2 X1-X3 500 85 100 550 91 ...

Page 14

... APPROX. SHIP WEIGHT Lbs. (Kg.) PL-112700 1 (0.5) PL-112701 1 (0.5) PL-112702 1 (0.5) PL-112703 1 (0.5) PL-112704 1 (0.5) PL-112705 1 (0.5) PL-112706 1 (0.5) PL-112707 1 (0.5) 68 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION APPROX. DIMENSIONS INCHES (CM 4.13 3.00 2.70 2.50 2.30 (10.5) (7.6) (6.8) (6.4) (5.8) 4.90 3.00 2 ...

Page 15

... H4 380V 277V 208V 95V X2 115V X3 X1 Group 600V 24V 12V TA Series Open Core & Coil Dimensional Drawings 50 VA Thru 2 KVA C A ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION Group B Group C 480V 240V H1 460 230 440 220 240V 230 220 120V 115 110 ...

Page 16

... 12V 24V Group 380V 277V 208V 95V X2 115V Series Open Core & Coil Dimensional Drawings ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION Group B Group C 480V 240V H1 460 230 440 220 240V 230 220 120V 115 110 Group G Group 480V 460 416V 440 ...

Page 17

... VA outside the control cabinet. This means the transformer must sheet metal enclosure instead of the usual open core and coil construction method. Acme meets this need by providing all of the power, protection, regulation and performance of our standard industrial control transformers in one UL -3R enclosure. ...

Page 18

... Low Voltage Directive 73/23/EEC and Electromagnetic Compatibility (EMC) Directive 89/336/EEC. 72 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION The Acme Electric AE and CE Series Industrial Control Transformers are designed specifically for machine tool control circuit applications. These transformers have the ability to handle potentially damaging high in-rush currents that occur when electromagnetic components are energized, without sacrificing the required stable output voltage ...

Page 19

... CE Series offers touch-proof terminals, isolating live contacts for additional safety. ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION Integrally mounted fuse blocks available in standard and touch-proof (CE Series) style. Epoxy encapsulated copper windings and internal terminations, providing isolation from external contaminants and physical damage ...

Page 20

... AE03-0250 4.13 (10.4) 350 AE03-0350 5.00 (12.7) 500 AE03-0500 5.53 (14.0) 750 AE03-0750 6.81 (17.3) 74 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION APPROX. DIMENSIONS INCHES (CM 3.00 (7.6) 2.81 (7.1) 2.03 (5.1) 3.00 (7.6) 2.81 (7.1) 2.53 (6.4) 3.41 (8.6) 3.09 (7.8) 2 ...

Page 21

... AE12-0250 4.16 (10.5) 350 AE12-0350 5.00 (12.7) 500 AE12-0500 5.84 (14.8) 750 AE12-0750 6.81 (17.3) ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION APPROX. DIMENSIONS INCHES (CM 3.00 (7.6) 2.81 (7.1) 2.03 (5.1) 3.00 (7.6) 2.81 (7.1) 2.53 (6.4) 3.41 (8.6) 3.09 (7.8) 2 ...

Page 22

... CE03-0250 4.13 (10.4) 350 CE03-0350 5.00 (12.7) 500 CE03-0500 5.53 (14.0) 750 CE03-0750 7.03 (17.8) 76 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION APPROX. DIMENSIONS INCHES (CM 3.00 (7.6) 2.81 (7.1) 2.25 (5.7) 3.41 (8.6) 2.81 (7.1) 2.25 (5.7) 3.75 (9.5) 3.09 (7.8) 2 ...

Page 23

... CE06-0300 4.53 (11.5) 350 CE06-0350 5.00 (12.7) 500 CE06-0500 6.00 (15.2) 750 CE06-0750 6.81 (17.3) ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION APPROX. DIMENSIONS INCHES (CM 3.00 (7.6) 2.81 (7.1) 2.53 (6.4) 3.75 (9.5) 3.22 (8.1) 2.53 (6.4) 4.34 (11.0) 3.41 (8.6) 2 ...

Page 24

... CONNECTION DETAILS FOR AE05 & CE05 H1-H2 H1-H3 H1-H4 208 220 380 440 230 400 460 240 416 480 78 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION 230 V 240 V 277 V 380 V 416 V 0.6 0.6 0.6 0.3 0.3 1.0 1.0 0.8 0.6 0.6 1 ...

Page 25

... & CE Series Dimensional Drawings ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION DESCRIPTION Fuse Kit: Primary Fuse Block EIC Series (2 Class CC Blocks) Fuse Kit: Primary & Secondary Fuse Block EIC Series (2 Class CC and 1 Midget Blocks) Fuse Kit: Primary Fuse Block EIC Series CE Listed w/ Covers (2 Class CC Blocks) Fuse Kit: Primary & ...

Page 26

... Marking must be applied to products being placed on the European market. The CE Marking does allow a product to be moved freely within the internal market of the European Union. The Directives that apply to Control or Power Distribution Transformers are: Low Voltage Directive, 73/23/EEC effective January 1, 1997 Electromagnetic Compatibility (EMC) Directive, 89/336/EEC effective ...

Page 27

... FS-3-1000 1000 870 FS-3-1500 1500 1290 FS-3-2000 2000 1680 FS-3-3000 3000 2465 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION ® INDUSTRIAL CONTROL TRANSFORMERS APPROX. DIMENSIONS INCHES (CM Reference Group IC (CE01): CE Series Industrial Control Transformers 50-750 VA See Pg 76 4.76 (12.1) 6.75 (17.1) 6 ...

Page 28

... VA — 40.0 82 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION ® INDUSTRIAL CONTROL TRANSFORMERS DESCRIPTION PRIMARY FUSE KIT FOR CLASS CC FUSES PRIMARY & SECONDARY FUSE KIT FOR CLASS CC PRIMARY FUSES & MIDGET SECONDARY FUSE PRIMARY FUSE KIT FOR MIDGET FUSES PRIMARY & ...

Page 29

... FINGER/GUARD SECTION ® FINGER/GUARD GROUP A 240V 120V 24V X2 ® FINGER/GUARD 50 VA Thru 2 KVA E 3 KVA ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION ® INDUSTRIAL CONTROL TRANSFORMERS Wiring Diagrams GROUP B 480V 240V 460 230 440 220 120V 115 110 X2 X1 Dimensional Drawings LUMBERTON, NC • ...

Page 30

... FINGER/GUARD SECTION NOTES 84 ACME ELECTRIC, POWER DISTRIBUTION PRODUCTS DIVISION ® INDUSTRIAL CONTROL TRANSFORMERS LUMBERTON, NC 800-334-5214 www.acmepowerdist.com • • • ...

Related keywords