Specifications of JMK325BJ226MM-T

Capacitance
22µF
Voltage - Rated
6.3V
Tolerance
±20%
Temperature Coefficient
X5R
Mounting Type
Surface Mount, MLCC
Operating Temperature
-55°C ~ 85°C
Applications
General Purpose
Package / Case
1210 (3225 Metric)
Size / Dimension
0.126" L x 0.098" W (3.20mm x 2.50mm)
Thickness
2.50mm
Dielectric Characteristic
X5R
Capacitance Tolerance
± 20%
Voltage Rating
6.3VDC
Capacitor Case Style
1210
No. Of Pins
2
Capacitor Mounting
SMD
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Ratings
-
Lead Spacing
-
Other names
587-1384-2
CE JMK325 BJ226MM-T
JMK325BJ226MM-T
【Test Methods and Remarks】
【Test Methods and Remarks】
【Test Methods and Remarks】
【Test Methods and Remarks】
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
mlcc05_reli_e-01
12. Temperature Cycle ( Thermal Shock)
Specified Value
13. Humidity (Steady state)
Specified Value
14. Humidity Loading
Specified Value
15. High Temperature Loading
Specified Value
Note1
Conditions for 1 cycle/ Step 1: Minimum operating temperature
Number of cycles: 5 times
Measurement shall be conducted : 24±2hrs under the standard condition
Temperature:40±2℃
Humidity:90 to 95% RH
Duration:500
Measurement shall be conducted : 24 ±2hrs under the standard condition
According to JIS C 5102 clause 9.9.
Temperature:40±2℃ Humidity:90 to 95% RH
Duration:500
Applied voltage: Rated voltage
Charge/discharge current:50mA max
Measurement shall be conducted : 24 ±2hrs under the standard condition
According to JIS C 5102 clause 9.10.
Temperature:125±3℃
Duration:1000
Applied voltage: Rated voltage x 2
Charge/discharge current:50mA max
Measurement shall be conducted : 24 ±2hrs under the standard condition
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
RELIABILITY DATA
Standard condition: Temperature: 5 to 35℃, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa
+24
-0
+24
-0
+48
-0
hrs
hrs
hrs
Step 2: Normal temperature
Step 3: Maximum operating temperature
Step 4: Normal temperature
When there are questions concerning measurement results, in order to provide correlation data, the test shall be conducted under the following condition.
Temperature: 20±2℃,
Unless otherwise specified, all the tests are conducted under the "standard condition".
Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa
Appearance: No abnormality
Capacitance change: ±2.5% max
Dissipation factor : Initial value
Insulation resistance: Initial value
Withstanding voltage (between terminals) : No abnormality
Appearance: No abnormality
Capacitance change: ±5% max
Dissipation factor : 0.5% max
Insulation resistance 50MΩ μF or 1000MΩ, whichever is smaller
Appearance: No abnormality
Capacitance change: ±7.5% max
Dissipation factor : 0.5% max
Insulation resistance: 25MΩ μF or 500MΩ, whichever is smaller
Appearance: No abnormality
Capacitance change: ±3% max
Dissipation factor : 0.35% max
Insulation resistance: 50MΩ μF or 1000MΩ, whichever is smaller
+0
-3
+0
-3
℃ 30±3 min.
℃ 30±3 min.
2 to 3 min.
2 to 3 min.
Note1
Note1
Note1
Note1
1 1
mlcc05_reli-R2