ADG758 Analog Devices, ADG758 Datasheet
ADG758
Available stocks
Related parts for ADG758
ADG758 Summary of contents
Page 1
... When disabled, all channels are switched OFF. Low power consumption and an operating supply range of 1 5.5 V make the ADG758 and ADG759 ideal for battery-powered, portable instruments. All channels exhibit break-before-make switching action preventing momentary shorting when switch- ing channels ...
Page 2
... Channel-to-Channel Crosstalk –3 dB Bandwidth C (OFF (OFF) D ADG758 ADG759 (ON ADG758 ADG759 POWER REQUIREMENTS I DD NOTES 1 Temperature range is as follows: B Version: –40°C to +85°C. 2 Guaranteed by design, not subject to production test. Specifications subject to change without notice Version – ...
Page 3
... MHz typ 13 pF typ 85 pF typ 42 pF typ 96 pF typ 48 pF typ µA typ 0.001 µA max 1.0 –3– ADG758/ADG759 Test Conditions/Comments mA Test Circuit 3 V V/3 V ...
Page 4
... Channel-to-Channel Crosstalk –3 dB Bandwidth C (OFF (OFF) D ADG758 ADG759 (ON ADG758 ADG759 POWER REQUIREMENTS NOTES 1 Temperature range is as follows: B Version: –40°C to +85°C. 2 Guaranteed by design, not subject to production test. Specifications subject to change without notice –2.5 V 10%, GND = 0 V, unless otherwise noted ...
Page 5
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the ADG758/ADG759 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality ...
Page 6
... ADG758/ADG759 V Most Positive Power Supply Potential DD V Most Negative Power Supply in a dual-supply application. In single-supply applications, this should be tied to SS ground at the device. GND Ground (0 V) Reference S Source Terminal. May be an input or output. D Drain Terminal. May be an input or output. IN Logic Control Input ...
Page 7
... D S Different Temperatures, Dual Supply 0. 0.08 SS 0.04 0.00 +25 C –0.04 –0.08 –0. for Different TPC 6. Leakage Currents as a Function –7– ADG758/ADG759 + – + 0.5 1.0 1.5 2 – DRAIN OR SOURCE VOLTAGE – ...
Page 8
... ADG758/ADG759 0.12 0.08 0.04 0.00 I (OFF) –0.04 S –0.08 –0.12 0 0.5 1.0 1 – TPC 7. Leakage Currents as a Function of V 0.12 0.08 I 0.04 D 0.00 I (OFF) –0.04 S –0.08 –0.12 –3.0 –2.5 –2.0 –1.5 –1.0 –0 – TPC 8. Leakage Currents as a Function 0.30 DD 0.25 0.20 0.15 I (OFF ...
Page 9
... FREQUENCY – Hz TPC 14. ON Response vs. Frequency REV –10 –20 –30 –40 10M 100M –3 TPC 15. Charge Injection vs. Source Voltage 10M 100M –9– ADG758/ADG759 +2. –2.5V SS –2 –1 ...
Page 10
... S2 THRU S7 A0 ADG758 * 2.4V EN GND *SIMILAR CONNECTION FOR ADG759 Test Circuit 5. Switching Time of Multiplexer THRU ADG758 * D 2.4V EN GND *SIMILAR CONNECTION FOR ADG759 0. ADDRESS DRIVE ( ...
Page 11
... Digital and analog NETWORK * ANALYZER inputs should always be applied after power supplies and ground OUT For single-supply operation the device as possible. V OUT V S –11– ADG758/ADG759 50% 50% t (EN) OFF 0.9V 0. (EN) ON (EN) OFF V OUT Q ...
Page 12
... ADG758/ADG759 PIN 1 INDICATOR 0.035 (0.90) MAX 0.033 (0.85) NOM SEATING PLANE Revision History Location Data Sheet changed from REV REV. A. Edits to General Description section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Update Outline Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 OUTLINE DIMENSIONS Dimensions shown in inches and (mm). 20-Lead Chip Scale Package (CP-20) 0.024 (0.60) 0.017 (0.42) 0.157 (4.0) 0.009 (0.24) BSC SQ ...