ADR530 Analog Devices, ADR530 Datasheet

no-image

ADR530

Manufacturer Part Number
ADR530
Description
Manufacturer
Analog Devices
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADR530ART-REEL7
Manufacturer:
AD
Quantity:
5 510
Part Number:
ADR530ART-REEL7
Manufacturer:
DELTA
Quantity:
5 510
Part Number:
ADR530ARTZ-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADR530BKSZ-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADR530BRT-R2
Manufacturer:
AT
Quantity:
250
Part Number:
ADR530BRT-REEL7
Manufacturer:
AD
Quantity:
5 510
Part Number:
ADR530BRT-REEL7
Manufacturer:
MAXIM
Quantity:
5 510
Part Number:
ADR530BRTZ-R7
Manufacturer:
AD
Quantity:
1 000
Part Number:
ADR530BRTZ-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
One Technology Way • P.O. Box 9106 • Norwood, MA 02062-9106 • Tel: 781/329-4700 • Fax: 781/326-8703 •
Long-Term Drift (LTD) in voltage references is a param-
eter that can be confusing and misleading. It is given as
a typical parameter in data sheets, but can cause sig-
nificant accuracy limitations in system. Unlike tempco
and initial accuracy, where a one-time calibration can be
used to eliminate these errors, attempts to reduce LTD
requires frequent system calibration. This can be both
time consuming and expensive.Therefore, it is important
to understand the significance of LTD.
Most data sheets specify LTD as ppm/1,000 hours.
1,000 hours is equal to 41.5 days, and in one year there
are 8,766 hours.Therefore, if a part is specified to change
by 70 ppm/1,000 hours, does this mean that in one year it
will change by 613 ppm? No, it does not.This is a common
mistake that is made by only reading the data sheet but
not understanding what LTD really is.
The following graph shows a typical LTD curve of a typical
ADI band gap reference. The output voltage of this part
has been recorded every hour for 1,000 hours in a controlled
environment with a temperature of 50C.
REV. 0
Figure 1. Typical Long-Term Drift Over 1,000 Hours
–100
–150
200
150
100
–50
50
0
0
100
200
300
400
The Effect of Long-Term Drift on Voltage References
TIME (Hours)
500
600
700
800
900 1,000
by Colm Brazil
As the graph shows, in the first 200 hours there is a lot of
movement in the part. After this initial movement there
is very little change in the V
Over the next 1,000 hours the variation is normally less
than one quarter of that in the first 1,000 hours. This
trend continues with the change being an approximate
cut in four from the previous time period. The changes
in output take a “drunken walk” pattern: the changes are
random and cannot be predicted, so the output might
change positive in the first time period but negative in
the second.
• 70 ppm/1,000 hours does not mean the part will change
• The changes are random, so if the part starts off in one di-
Ways to Eliminate LTD Effects
• Calibrate the system after 200 hours, thus eliminating
• Burn in the part for a short period of time to eliminate
by 613 over one year but will change more in the area
of 140 ppm/year
rection it does not mean it will continue in that direction
the early changes
the early changes
APPLICATION NOTE
OUT
for the last 800 hours.
www.analog.com
AN-713

Related parts for ADR530

ADR530 Summary of contents

Page 1

One Technology Way • P.O. Box 9106 • Norwood, MA 02062-9106 • Tel: 781/329-4700 • Fax: 781/326-8703 • The Effect of Long-Term Drift on Voltage References Long-Term Drift (LTD) in voltage references is a param- eter that can be confusing ...

Page 2

... Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. –2– ...

Related keywords