M-FIAM5 Vicor Corporation, M-FIAM5 Datasheet

no-image

M-FIAM5

Manufacturer Part Number
M-FIAM5
Description
Military 28Vin Filter Input Attenuator Module
Manufacturer
Vicor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M-FIAM5BH13
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
M-FIAM5BH21
Manufacturer:
INFINEON
Quantity:
1 143
Part Number:
M-FIAM5BH21
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
M-FIAM5BHG1
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
M-FIAM5BHN1
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
M-FIAM5BM13
Manufacturer:
MSC
Quantity:
12 000
Part Number:
M-FIAM5BM13
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
M-FIAM5BM21
Manufacturer:
REALTEK
Quantity:
3 000
Part Number:
M-FIAM5BM21
Manufacturer:
LT
Quantity:
62
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
45
Features
• EMI filtering-MIL-STD-461E
• Transient protection-MIL-STD-704E
• Environments-MIL-STD-810, MIL-STD-202
• Environmental stress screening
• Low profile mounting options
• Output current up to 20 Amps
• Mini sized package
• Inrush current limiting
• Reverse polarity protection
Product Highlights
The M-FIAM5 is a DC front-end module
that provides EMI filtering and transient
protection required in military applications.
The M-FIAM5 enables designers using
Vicor 2nd Generation 24V DC-DC converters
to meet conducted emission/conducted
susceptibility per MIL-STD-461E; and
input transients per MIL-STD-704E
M-FIAM5 accepts an input voltage of
18-36Vdc and delivers output current
up to 20 Amps.
M-FIAM5 is housed in an industry
standard "half brick" module measuring
2.28" x 2.2" x 0.5" and depending upon
model selected, may be mounted on-board
or in-board for height critical applications.
Compatible Products
• 2nd Generation 24V Input
Part Number Format
M-FIAM5 M 2
*Compatible with SurfMate and InMate socketing system.
Thermal Resistance
Product Grade(°C)
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to sink; 1000 LFM
M = –55 to +100
Product
H = –40 to +100
DC-DC converters
*S=Short ModuMate
*N=Long ModuMate
1 = Short
2 = Long
Pin Style
Set your site on VICOR at www.vicorpower.com
1 = Slotted
2 = Threaded
3 = Thru-hole
Baseplate
2.2°C/Watt
1
0.16°C/Watt
0.1°C/Watt
7.9°C/Watt
1
. The
Typ
1
Absolute Maximum Rating
Specifications
(typical at TBP = 25ºC, nominal line, 75% load, unless otherwise specified)
1
M-FIAM5
Military 28Vin Filter
Input Attenuator Module
MTBF per MIL-HDBK-217F
Parameter
+In to –In
+In to –In
Mounting torque
Pin Soldering temperature
Pin Soldering temperature
Operating temperature H–Grade
Storage temperature H–Grade
Operating temperature M–Grade
Storage temperature M–Grade
Parameter
Input voltage
Output current
Inrush limiting
Transient immunity
EMI:MIL-STD-461E
Dielectric withstand
Efficiency
Internal voltage drop
ON/OFF control
External capacitance
Weight
Warranty
MIL-STD-704E Compliance requires an external circuit. See addendum A
Temp
Conducted emissions:
Conducted susceptibility: CS101, CS114, CS115, CS116
Enable (ON)
Disable (OFF)
25°C
50°C
65°C
57,9 x 55,9 x 12,7 mm
Shown actual size:
2.28 x 2.2 x 0.5 in
Environment
Ground Benign:G.B.
Naval Sheltered:N.S.
Airborne Inhabited Cargo:A.I.C.
MFIAM5
18Vdc
MIL-STD-704E
CE101, CE102
96%
0.0Vdc
3.5Vdc
330µF
Min
-40 to +100
-55 to +125
-55 to +100
-65 to +125
1,500Vrms
500 (260)
750 (390)
2,121Vdc
Rating
3.1 (88)
5(0.57)
28Vdc
Typ
98%
0.5
36
50
0.007A/µF
1000µF
1.0Vdc
5.0Vdc
4 (113)
°F(°C)
°F(°C)
36Vdc
in-lbs
Unit
Max
20A
Vdc
Vdc
1.0
°C
°C
°C
°C
2
3,334,295
786,893
650,187
MTBF
Continuous
100ms
6 each, #4-40 or M3
<5 sec; wave solder
<7 sec; hand solder
Baseplate
Baseplate
Continuous
See footnote 1
Input/Output to Base
Input/Output to Base
@20A, 100°C baseplate
Referenced to –Vout.
100kΩ internal pull-up resistor
See illustration C1 on page 3.
50V
Ounces (grams)
Years
Notes
Remarks
Rev. 1.7
Unit
Hrs
Hrs
Hrs
Page 1 of 5

Related parts for M-FIAM5

M-FIAM5 Summary of contents

Page 1

... Output current Amps • Mini sized package • Inrush current limiting • Reverse polarity protection Product Highlights The M-FIAM5 front-end module that provides EMI filtering and transient protection required in military applications. The M-FIAM5 enables designers using Vicor 2nd Generation 24V DC-DC converters to meet conducted emission/conducted susceptibility per MIL-STD-461E ...

Page 2

... MIL-STD-810F, Method 507.4, Procedure I, Cycle I, 240 hrs, 95% RH. Solder Test MIL-STD-202F, Method 208, 8 hour aging. Transient Immunity Figure 2 – Transient Immunity: M-FIAM5 output response to an input transient. Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at www.vicorpower.com Environmental Stress Screening H Grade Operating Temp ...

Page 3

... DENOTES 25,40 ±0.003 0.195 1.400* TOL = ±0,08 4,95 35,56 Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at www.vicorpower.com – – –IN ON 2nd Generation EMI OFF PR GND C1 24Vdc Input NC M-FIAM5 DC-DC Converters +IN 0.50 ±0.02 12,7 ±0,5 2.20 55,9 1.74 44,2 style 2 & 3 0.12* 0.20** baseplates only 3,1 5,1 (4X)*** ...

Page 4

... MIL-STD-704E Transient / Overvoltage Protection The standard (COTS) 24V input 2nd Generation Converter Modules may be used in Military 28 volt applications. The M-FIAM5 provides compliance to MIL-STD-461E conducted emissions and susceptibility standards. Additional circuitry, as illustrated in the accompanying schematic (see Fig. 1), provides compliance to the MIL-STD-704E transient overvoltage specification ...

Page 5

... Vicor for its use. No license is granted by implication or otherwise under any patent or patent rights of Vicor. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon request. ...