S8VM-01505 Omron, S8VM-01505 Datasheet

POWER SUPPLY 5V 3A OPEN FRAME

S8VM-01505

Manufacturer Part Number
S8VM-01505
Description
POWER SUPPLY 5V 3A OPEN FRAME
Manufacturer
Omron
Series
S8VMr
Datasheets

Specifications of S8VM-01505

Voltage - Output
5V
Number Of Outputs
1
Power (watts)
15W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 3A
Size / Dimension
3.17" L x 1.06" W x 3.21" H (80.5mm x 27mm x 81.5mm)
Power (watts) - Rated
15W
Operating Temperature
-10°C ~ 70°C
Efficiency
75%
Approvals
CE, CSA, cUL, cUR, EN, TUV, UL
Product
Switching
Mounting Style
Bottom
Open Frame/enclosed
Open Frame
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
S8VM01505
Power Supply Featuring OMRON’s Unique, New Undervoltage Alarm Function with
Compact Body Contributing to Machine Downsizing
• New undervoltage alarm function assists in determining causes of errors (S8VM-@@@24A@/P@ only).
• Power failure alarm function provides notification of output voltage errors (300-, 600-, and 1,500-W models only).
• Broad range of possibilities with 8 capacities and 29 models to choose from.
• RoHS-compliant including lead-free construction.
• Safety standards: UL508/60950-1/1604, CSA C22.2 No. 14/No. 60950-1/No. 213, EN50178, EN60950-1 (The 300-, 600-, and
• Harmonic current emissions: Conforms to EN61000-3-2 (except for 15- and 30-W models).
• New, attentive design prevents screws from falling out of terminal block (except for output terminals of 300-, 600-, and 1,500-W
• Finger protection prevents electric shock.
• DIN Rail mounting.
Model Number Structure
■ Model Number Legend
Note: Not all combinations are possible. Please refer to the list of models in Ordering Information on page 2.
Note: 1. The housing and terminal of the connector for the undervoltage alarm output are provided with the S8VM-05024A@/P@, S8VM-
S8VM- @@@@@@@
1. Power Ratings
2. Output Voltage
1,500-W models will not conform to safety standards if the customer replaces the fan.)
models).
Note: Refer to Precautions for Safe Use on page 32.
Switch Mode Power Supply
S8VM (15/30/50/100/150/300/600/1,500-W Models)
015:
030:
050:
100:
150:
300:
600:
152: 1,500 W
05: 5 V
12: 12 V
15: 15 V
24: 24 V
2. Bottom mounting models cannot be used for front mounting. For a front mounting configuration, use a DIN Rail mounting bracket model
3. A forced-air cooling method with a fan is used with 300-, 600-, and 1,500-W models.
10024A@/P@ and S8VM-15024A@/P@.
or Mounting Brackets (sold separately).
100 W
150 W
300 W
600 W
15 W
30 W
50 W
1
2
3 4
3. Configuration/Functions
4. Configuration
None: Open-frame type Standard type
C:
A:
P:
None
D
Covered type
Covered type
Covered type
Switch Mode Power Supply
Bottom mounting type (See note 2.)
DIN Rail mounting bracket type
Standard type
Undervoltage alarm type (Sinking)
(See note 1.)
Undervoltage alarm type (Sourcing)
(See note 1.)
S8VM
1

Related parts for S8VM-01505

S8VM-01505 Summary of contents

Page 1

... V 24 Note: 1. The housing and terminal of the connector for the undervoltage alarm output are provided with the S8VM-05024A@/P@, S8VM- 10024A@/P@ and S8VM-15024A@/P@. 2. Bottom mounting models cannot be used for front mounting. For a front mounting configuration, use a DIN Rail mounting bracket model or Mounting Brackets (sold separately) ...

Page 2

... S8VM-03024D --- --- S8VM-05005D --- --- S8VM-05012D --- --- S8VM-05015D --- --- S8VM-05024D --- --- S8VM-10005D --- --- S8VM-10012D --- --- S8VM-10015D --- --- S8VM-10024D --- --- S8VM-15005D --- --- (See note 2.) S8VM-15012D --- --- S8VM-15015D --- --- S8VM-15024D --- --- S8VM-01505CD --- --- S8VM-01512CD --- --- S8VM-01515CD --- --- S8VM-01524CD S8VM-01524AD (See note 1.) S8VM-03005CD --- --- S8VM-03012CD --- --- S8VM-03015CD --- --- S8VM-03024CD S8VM-03024AD (See note 1.) S8VM-05005CD --- --- S8VM-05012CD --- --- S8VM-05015CD --- --- S8VM-05024CD S8VM-05024AD S8VM-05024PD S8VM-10005CD --- --- S8VM-10012CD --- --- S8VM-10015CD --- ...

Page 3

... A max. (for cold start at 25° max. (for cold start at 25°C) −20% to 20% (with V. ADJ) (S8VM-@@@24A@/P@: −10% to 20%) 3.2% (p-p) max. (5 V), 3.2% (p-p) max. (5 V), 1.5% (p-p) max. (12 V), 1 ...

Page 4

... and 15 V), 120% to 160% of rated load current (S8VM-30024C), 115% to 160% of rated load current (S8VM- 60024C), voltage drop ( and 24 V), voltage drop, intermittent (5 V), automatic reset Yes (See note 4 ...

Page 5

... Connections ■ Block Diagrams S8VM-015@@@@ ( (L) Fuse 2 A INPUT AC (N) /FG S8VM-030@@@@ ( (L) Fuse INPUT 3. (N) /FG S8VM-050@@@@ ( (L) Fuse Noise 2 A INPUT filter AC (N) Rectification Harmonic current suppression Drive control Overcurrent detection circuit /FG Noise filter Rectification Inrush Smoothing Rectifier/smoothing current circuit protection circuit Drive control ...

Page 6

... S8VM-100@@@@ (100 W) Inrush Harmonic current current protection Rectification suppression circuit AC (L) Fuse Noise INPUT 3.15 A filter AC (N) Drive Drive control circuit Overcurrent detection circuit /FG S8VM-150@@@@ (150 W) Harmonic current Rectification suppression AC (L) Fuse Noise INPUT 5 A filter AC (N) Drive Drive control circuit ...

Page 7

... S8VM-600@@C (600 W) AC (L) Noise Fuse INPUT filter (N) Rectification Auxiliary power supply circuit S8VM-15224C (1,500 W) AC (L) Fuse Noise INPUT 30 A filter AC (N) Auxiliary power supply circuit /FG Inrush Harmonic current current protection suppression circuit Fan detection Power failure Smoothing alarm detection Rectifier/smoothing circuit ...

Page 8

... Note: 1. The fuse is located on the (L) side NOT user-replace- able mounting is performed using a DIN Rail, the protective earthing connection is the panel mounting hole shown in the figure below. (A protective earthing connection stipulated in safety stan- dards is used. Connect the ground completely (S8VM- @@@@@D only)). Ground terminal: M3 (Depth max.)/Ground wire: AWG ...

Page 9

... A 80 Covered type −20 − Ambient temperature (˚C) Horizontal Mounting 120 Opened type 100 A 80 Covered type −20 − Ambient temperature (°C) Switch Mode Power Supply Face-up Mounting 120 Opened type 100 A 80 Covered type −20 − Ambient temperature (°C) S8VM 9 ...

Page 10

... Mounting screw tightening torque (recommended value: M3 (0.49 N·m)) 10 Switch Mode Power Supply ■ Remote Sensing Function (S8VM-100@@@@/150@@@@ only) This function compensates a voltage drop on the load lines. To use this function, connect after removing the two short bars of the remote sensing terminal. *1 Note: 1 ...

Page 11

... Undervoltage Alarm Function (Indication and Output) (Only S8VM-@@@24A@/P output voltage drop is detected with an S8VM-@@@24A@/P@ with undervoltage alarm function, the DC LOW indicator will light to notify of an output error. The transistor also sends an output externally to notify of the error (except for the S8VM-01524A@ and S8VM-03024A@). ...

Page 12

... Output drop The output voltage has ON (approx. 80% of dropped gradually, re- → rated output mains low, and is continu- OFF voltage) ing to fluctuate. No output voltage is being → No output OFF output. ON The output voltage is un- → Unstable output stable. OFF S8VM Power Supply status diagnosis ...

Page 13

... Check whether the +S and -S terminals are open. If so, the overvoltage protection function is activated. Therefore, turn OFF the input power and wait at least three minutes before turning it ON again. (S8VM- 10024A@/P@ and S8VM-15024A@/P@ models only) Remove the cause of the output short-circuit ...

Page 14

... Ground terminal: M4 (Depth max.)/Ground wire: AWG 18 3. The enclosed standard connector for signal I/O is mounted to CN when S8VM is shipped. The enclosed signal I/O con- nector shorts between 1 and 2, between 3 and 4, and be- tween 7 and 8. Do not connect a load to the output voltage monitor termi- nals (+V, -V) ...

Page 15

... When mounting two or more Power Supplies side-by-side, allow at least 20 mm spacing between them. Always provide at least mounting space for the surface with the fan mounted. Be sure to provide at least 50 mm (S8VM- 300@@C/600@@C) or 100 mm (S8VM-15224C) of mount- ing space on the opposite side of the surface with the fan mounted ...

Page 16

... Note: 1. This function monitors the voltage at the Power Supply out- put terminals. To check actual voltage, measure the voltage on the load side. 2. Outputs are forced OFF if the built-in fan motor stops (S8VM-15224C only). 3. Remove the standard supplied connector and prepare a connector separately. 16 Switch Mode Power Supply ■ ...

Page 17

... Power Supply may occasionally be deteriorated or damaged. 2. The internal parts may possibly be deteriorated or dam- aged. Do not use the Power Supply for applications where the load causes frequent inrush current and overload. Switch Mode Power Supply 100 S8VM 17 ...

Page 18

... ON again. Alternatively turn OFF the remote control signal long enough to cool sufficiently and then turn it ON again. ■ Peak Output Current (S8VM-30024C/60024C/15224C Only) The peak current must satisfy the following conditions. Reduce the peak current according to the load rate of the derating curve. ...

Page 19

... Bottom Mounting Models S8VM-015@@ S8VM-015@@C S8VM-01524A Two, M3 (depth: 8 max.) Note: The image is the S8VM-01524 Model. Two, M3 (depth: 8 max.) Note: The image is the S8VM-01524A Model. S8VM-030@@ S8VM-030@@C S8VM-03024A Two, M3 (depth: 8 max.) Note: The image is the S8VM-03024 Model. Two, M3 (depth: 8 max.) Note: The image is the S8VM-03024A Model. ...

Page 20

... S8VM-05024P 8.5±0.5 Two, M3 (depth: 8 max.) 23.5±0.3 15±0.2 Note: The image is the S8VM-05024 Model. 8.5±0.5 Two, M3 (depth: 8 max.) 23.5±0.3 15±0.2 Note: The image is the S8VM-05024A Model. S8VM-100@@ S8VM-100@@C S8VM-10024A S8VM-10024P 68±0.5 8.5±0.5 Two, M3 (depth: 8 max.) 25±0.2 15±0.2 7.5± ...

Page 21

... S8VM-15024P 68±0.5 8.5±0.5 Two, M3 (depth: 8 max.) 8.5±0.5 26.5±0.2 15±0.2 7.5±0.2 25±0.5 Note: The image is the S8VM-15024 Model. 68±0.5 8.5±0.5 Two, M3 (depth: 8 max.) 8.5±0.5 26.5±0.2 15±0.2 7.5±0.2 25±0.5 Note: The image is the S8VM-15024A Model. ...

Page 22

... DIN Rail Mounting Bracket Models S8VM-015@@D S8VM-015@@CD S8VM-01524AD Note: The image is the S8VM-01524D Model. Note: The image is the S8VM-01524AD Model. S8VM-030@@D S8VM-030@@CD S8VM-03024AD Note: The image is the S8VM-03024D Model. Note: The image is the S8VM-03024AD Model. 22 Switch Mode Power Supply (15-W, 30-W, 50-W, 100-W, 150-W Models) 17 ...

Page 23

... S8VM-050@@D S8VM-050@@CD S8VM-05024AD S8VM-05024PD Note: The image is the S8VM-05024D Model. Note: The image is the S8VM-05024AD Model. S8VM-100@@D S8VM-100@@CD S8VM-10024AD S8VM-10024PD Note: The image is the S8VM-10024D Model. Note: The image is the S8VM-10024AD Model. 17.6 max. 14 120.5 3.5 max. 82.5 130.4 5.4 (Sliding: 9 max max ...

Page 24

... S8VM-150@@D S8VM-150@@CD S8VM-15024AD S8VM-15024PD Note: The image is the S8VM-15024D Model. Note: The image is the S8VM-15024AD Model. 24 Switch Mode Power Supply 17.6 max. 14 160.5 82.5 170.4 5.4 (Sliding: 9 max.) 14 164.5 84.5 46.2 174.4 5.4 (Sliding: 9 max.) S8VM 3.5 max. 39.1 15 max. 45.6 ...

Page 25

... Four, M4 (depth: 6 max.) 60±0.5 11 10.5 40±0.5 Note: The image is the S8VM-30024C Model. S8VM-600@@C 101.8 Note: The image is the S8VM-60024C Model. S8VM-15224C 126.5 82 Note: M8 bolts and nuts for the output terminals are not included. (300-W, 600-W, 1,500-W Models) 188 max. 22 max. 105±0 max ...

Page 26

... 2.3 A Using the Mounting Bracket 20±0 2.3 S8VM Model S82Y-VM10B S82Y-VM20B S82Y-VM10F S82Y-VM30B S82Y-VM30S S82Y-VM30F S82Y-VM30D S82Y-VM60B S82Y-VM60S S82Y-VM60F S82Y-VM60D Screws Used A: Accessories (Use the enclosed screws in two places for 15-W and 30-W models and in three places for 50-W mod- B els ...

Page 27

... Mounting holes for 100-W models e = Mounting holes for 150-W models Using the Mounting Bracket Three, 4.5 dia Switch Mode Power Supply Screws Used A: Accessories A (Use the enclosed screws in four places (three places) Mounting screw tightening torque (recom- mended): 1.27 N·m S8VM 27 ...

Page 28

... Switch Mode Power Supply Using the Mounting Bracket 202 215 Using the Mounting Bracket 215.3 243 max. S8VM Screws Used A A: Accessories A (Use the enclosed screws in four places (three places) Mounting screw tightening torque (recom- mended): 1.27 N·m B ...

Page 29

... N· Screws Used A: Accessories (Use the enclosed B screws in four places (three places) Mounting screw tightening torque (recommended): A 1.27 N· Screws Used B A: Accessories (Use the enclosed A screws in four places (three places) Mounting screw tightening A torque (recommended): 1.27 N·m A S8VM 29 ...

Page 30

... Switch Mode Power Supply Using the Mounting Bracket 222.3 257 max. A Using the Mounting Bracket 222.3 257 max. 9.5 S8VM Screws Used A: Accessories (Use the enclosed screws in A four places (three places) Mounting screw tightening torque (recommended): 1.27 N·m ...

Page 31

... Terminal and Housing Replacement Fan Unit for 300-W Models Replacement Fan Unit for 600-W Models Replacement Fan Unit for a 1,500-W Model Undervoltage Alarm Output Wiring Cable S82Y-VM60D (for S8VM-05024A@/05024P@/10024A@/10024P@/15024A@/15024P@ Only) : XHP-3 (Manufactured by JST AWG24 3,000±50 ■ ...

Page 32

... Be sure to remove the sheet covering the Power Supply for machining before power-ON so that it does not interfere with heat dissipation. (See Use the following material for the wires to be connected to the S8VM note 1.) to prevent smoking or ignition caused by abnormal loads. Over heating or fire can result from inadequately sized wiring materials when problems occur at the load ...

Page 33

... The current rating for the output terminals on the S8VM-300@@ per terminal. The current rating for the output terminals on the S8VM-600@@ per terminal. Use two terminals together if a current exceeding the terminal rating is used. Use min. 60°C or 60/75°C wire. Use copper conductors only. ...

Page 34

... Default Setting: Set at the rated voltage Adjustable Range: Adjustable with output voltage adjuster (V.ADJ) on the front panel of the Power Supply from − 20% to 20% of the rated output voltage ( − 10% to 20% of the rated voltage for S8VM- @@@24A@/P@) Turning clockwise increases the output voltage and turning counterclockwise decreases the output voltage ...

Page 35

... S8VM onto the Rail until the Rail stopper clicks into place, hook section A over the edge of the Rail and push in the direction remove the S8VM from the DIN Rail, insert a screwdriver into section C and pull the S8VM away from the Rail min. Switch Mode Power Supply 70 80 100 Exhaust temperature: ° ...

Page 36

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 37

Cat. No. T031-E1-02 06/06 Specifications subject to change without notice Printed in USA ...