XPSAC3421 SQUARE D, XPSAC3421 Datasheet

no-image

XPSAC3421

Manufacturer Part Number
XPSAC3421
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet
Product data sheet
Characteristics
Complementary
Mar 31, 2012
Supply frequency
Power consumption in VA
Control circuit voltage
Breaking capacity
Breaking capacity
Output thermal current
[Ith] conventional free air thermal current
Associated fuse rating
Minimum output current
Minimum output voltage
Response time on input open
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
XPSAC3421
module XPSAC - Emergency stop - 115 V AC
Main
Range of product
Product or component
type
Safety module name
Safety module applica-
tion
Function of module
Safety level
Safety reliability data
Type of start
Connections - terminals
Output type
Number of additional
circuits
[Us] rated supply volt-
age
50/60 Hz
<= 7 VA AC
115 V
C300: 180 VA, AC-15 (holding) for relay output
C300: 1800 VA, AC-15 (inrush) for relay output
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
6 A per relay for relay output
10.5 A
4 A fuse type gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN
VDE 0660 part 200
6 A fuse type fast blow for relay output conforming to EN/IEC 60947-5-1, DIN
VDE 0660 part 200
10 mA for relay output
16 V for relay output
<= 100 ms
300 V (degree of pollution: 2) conforming to IEC 60647-5-1, DIN VDE 0110 part 1
4 kV overvoltage category III conforming to IEC 60647-5-1, DIN VDE 0110 part 1
Preventa Safety automation
Preventa safety module
XPSAC
For emergency stop and switch monitoring
Emergency stop
Switch monitoring
Can reach PL e/category 4 conforming to EN/ISO
13849-1
Can reach SILCL 3 conforming to EN/IEC 62061
MTTFd = 210.4 years conforming to EN/ISO
13849-1
DC > 99 % conforming to EN/ISO 13849-1
PFHd = 3.56E-9 1/h conforming to EN/IEC 62061
Unmonitored
Captive screw clamp terminals (1 x 0.14...1 x 2.5
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (1 x 0.14...1 x 2.5
mm²)solid cable with cable end, with double bezel
Captive screw clamp terminals (1 x 0.25...1 x 1.5
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (1 x 0.25...1 x 2.5
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.14...2 x 0.75
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.14...2 x 0.75
mm²)solid cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.25...2 x 1
mm²)flexible cable with cable end, with double bezel
Captive screw clamp terminals (2 x 0.5...2 x 1.5
mm²)flexible cable with cable end, with double bezel
Relay instantaneous opening 3 NO, volt-free
1 solid state output
115 V AC (- 15...15 %)
1

Related parts for XPSAC3421

XPSAC3421 Summary of contents

Page 1

... Associated fuse rating Minimum output current Minimum output voltage Response time on input open [Ui] rated insulation voltage [Uimp] rated impulse withstand voltage Mar 31, 2012 XPSAC3421 module XPSAC - Emergency stop - 115 V AC Main Range of product Preventa Safety automation Product or component Preventa safety module ...

Page 2

Local signalling Current consumption Mounting support Product weight Environment Standards Product certifications IP degree of protection Ambient air temperature for operation Ambient air temperature for storage 2 2 LEDs 115 V AC (on power supply ...

Page 3

... Product data sheet Dimensions Drawings Dimensions XPSAC3421 3 ...

Page 4

... Product data sheet Connections and Schema Wiring Diagrams Refer to the Instruction Sheet To download the instruction sheet, follow below procedure: 1 Click on Download & Documents. 2 Click on Instruction sheet. 4 XPSAC3421 ...

Related keywords