DSPIC33FJ128GP206A-I/MR Microchip Technology, DSPIC33FJ128GP206A-I/MR Datasheet - Page 303

IC DSPIC MCU/DSP 128K 64-QFN

DSPIC33FJ128GP206A-I/MR

Manufacturer Part Number
DSPIC33FJ128GP206A-I/MR
Description
IC DSPIC MCU/DSP 128K 64-QFN
Manufacturer
Microchip Technology
Series
dsPIC™ 33Fr
Datasheet

Specifications of DSPIC33FJ128GP206A-I/MR

Core Processor
dsPIC
Core Size
16-Bit
Speed
40 MIPs
Connectivity
I²C, IrDA, LIN, SPI, UART/USART
Peripherals
AC'97, Brown-out Detect/Reset, DMA, I²S, POR, PWM, WDT
Number Of I /o
53
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 18x10b/12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-VFQFN, Exposed Pad
Product
DSCs
Processor Series
DSPIC33F
Core
dsPIC
3rd Party Development Tools
52713-733, 52714-737, 53276-922, EWDSPIC
Development Tools By Supplier
PG164130, DV164035, DV244005, DV164005, PG164120, DM240001, DV164033
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
TABLE 25-40: ADC CONVERSION (12-BIT MODE) TIMING REQUIREMENTS
 2009 Microchip Technology Inc.
AC CHARACTERISTICS
AD50a T
AD51a t
AD55a t
AD56a F
AD57a t
AD60a t
AD61a t
AD62a t
AD63a t
Note 1:
Param
No.
2:
3:
RC
CONV
SAMP
PCS
PSS
CSS
DPU
Symbol
AD
CNV
These parameters are characterized but not tested in manufacturing.
Because the sample caps will eventually lose charge, clock rates below 10 kHz can affect linearity
performance, especially at elevated temperatures.
t
During this time, the ADC result is indeterminate.
DPU
is the time required for the ADC module to stabilize when it is turned on (AD1CON1<ADON> = 1).
ADC Clock Period
ADC Internal RC Oscillator
Period
Conversion Time
Throughput Rate
Sample Time
Conversion Start from Sample
Trigger
Sample Start from Setting
Sample (SAMP) bit
Conversion Completion to
Sample Start (ASAM = 1)
Time to Stabilize Analog Stage
from ADC Off to ADC On
dsPIC33FJXXXGPX06A/X08A/X10A
(2)
Characteristic
(2)
(2,3)
(2)
Timing Parameters
Clock Parameters
Conversion Rate
Preliminary
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
2.0 T
2.0 T
Operating temperature
3 T
117.6
Min.
AD
AD
AD
0.5 T
14 T
Typ
250
(1)
AD
AD
3.0 T
3.0 T
Max.
500
20
AD
AD
-40°C  T
-40°C  T
Units
ksps
ns
ns
ns
s
A
A
 +85°C for Industrial
 +125°C for Extended
Auto-Convert Trigger
(SSRC<2:0> = 111) not
selected
DS70593B-page 303
Conditions

Related parts for DSPIC33FJ128GP206A-I/MR