P87C52SBPN,112 NXP Semiconductors, P87C52SBPN,112 Datasheet - Page 16

IC 80C51 MCU 8K OTP 40-DIP

P87C52SBPN,112

Manufacturer Part Number
P87C52SBPN,112
Description
IC 80C51 MCU 8K OTP 40-DIP
Manufacturer
NXP Semiconductors
Series
87Cr
Datasheet

Specifications of P87C52SBPN,112

Program Memory Type
OTP
Program Memory Size
8KB (8K x 8)
Package / Case
40-DIP (0.600", 15.24mm)
Core Processor
8051
Core Size
8-Bit
Speed
16MHz
Connectivity
EBI/EMI, UART/USART
Peripherals
POR
Number Of I /o
32
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Processor Series
P87C5x
Core
80C51
Data Bus Width
8 bit
Data Ram Size
256 B
Interface Type
UART
Maximum Clock Frequency
33 MHz
Number Of Programmable I/os
32
Number Of Timers
3
Operating Supply Voltage
2.7 V to 5.5 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-1012-5
935253690112
P87C52SBPN
Philips Semiconductors
and 1 and exclude Slave 2 use address 1110 0100, since it is
necessary to make bit 2 = 1 to exclude slave 2.
The Broadcast Address for each slave is created by taking the
logical OR of SADDR and SADEN. Zeros in this result are trended
as don’t-cares. In most cases, interpreting the don’t-cares as ones,
the broadcast address will be FF hexadecimal.
2000 Aug 07
NOTE:
*SMOD0 is located at PCON6.
**f
80C51 8-bit microcontroller family
4 K/8 K OTP/ROM low voltage (2.7 V–5.5 V),
low power, high speed (33 MHz), 128/256 B RAM
OSC
Tl
Symbol
FE
SM0
SM1
SM2
REN
TB8
RB8
Rl
= oscillator frequency
Bit Addressable
Bit:
Function
Framing Error bit. This bit is set by the receiver when an invalid stop bit is detected. The FE bit is not cleared by valid
frames but should be cleared by software. The SMOD0 bit must be set to enable access to the FE bit.
Serial Port Mode Bit 0, (SMOD0 must = 0 to access bit SM0)
Serial Port Mode Bit 1
SM0
Enables the Automatic Address Recognition feature in Modes 2 or 3. If SM2 = 1 then Rl will not be set unless the
received 9th data bit (RB8) is 1, indicating an address, and the received byte is a Given or Broadcast Address.
In Mode 1, if SM2 = 1 then Rl will not be activated unless a valid stop bit was received, and the received byte is a
Given or Broadcast Address. In Mode 0, SM2 should be 0.
Enables serial reception. Set by software to enable reception. Clear by software to disable reception.
The 9th data bit that will be transmitted in Modes 2 and 3. Set or clear by software as desired.
In modes 2 and 3, the 9th data bit that was received. In Mode 1, if SM2 = 0, RB8 is the stop bit that was received.
In Mode 0, RB8 is not used.
Transmit interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or at the beginning of the stop bit in the
other modes, in any serial transmission. Must be cleared by software.
Receive interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or halfway through the stop bit time in
the other modes, in any serial reception (except see SM2). Must be cleared by software.
0
0
1
1
SCON Address = 98H
(SMOD0 = 0/1)*
SM0/FE
7
SM1
0
1
0
1
SM1
Mode
6
0
1
2
3
Figure 7. SCON: Serial Port Control Register
SM2
5
Description
shift register
8-bit UART
9-bit UART
9-bit UART
REN
4
Baud Rate**
f
variable
f
variable
OSC
OSC
16
TB8
/12
/64 or f
3
cares”. This effectively disables the Automatic Addressing mode and
Upon reset SADDR (SFR address 0A9H) and SADEN (SFR
address 0B9H) are leaded with 0s. This produces a given address
of all “don’t cares” as well as a Broadcast address of all “don’t
allows the microcontroller to use standard 80C51 type UART drivers
which do not make use of this feature.
OSC
RB8
/32
2
80C51/87C51/80C52/87C52
Tl
1
Rl
0
Reset Value = 0000 0000B
Product specification
SU00043

Related parts for P87C52SBPN,112