EZ80F92AZ020EG Zilog, EZ80F92AZ020EG Datasheet - Page 89

IC ACCLAIM MCU 128KB 100LQFP

EZ80F92AZ020EG

Manufacturer Part Number
EZ80F92AZ020EG
Description
IC ACCLAIM MCU 128KB 100LQFP
Manufacturer
Zilog
Series
eZ80® Acclaim!®r
Datasheets

Specifications of EZ80F92AZ020EG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, WDT
Number Of I /o
24
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
100-LQFP
Processor Series
EZ80F92x
Core
eZ80
Data Bus Width
8 bit
Data Ram Size
8 KB
Interface Type
I2C, IrDA, SPI, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
24
Number Of Timers
6
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Development Tools By Supplier
eZ80F920200ZCOG
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Lead Free Status / Rohs Status
 Details
Other names
269-3871
EZ80F92AZ020EG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EZ80F92AZ020EG
Manufacturer:
Zilog
Quantity:
10 000
PS015313-0508
Table 32. Timer Control Register(TMR0_CTL = 0080h, TMR1_CTL = 0083h,
TMR2_CTL = 0086h, TMR3_CTL = 0089h, TMR4_CTL = 008Ch, or TMR5_CTL =
008Fh)
Bit
Reset
CPU Access
Note: R = Read only; R/W = Read/Write.
Bit
Position
7
PRT_IRQ
6
IRQ_EN
5
4
PRT_MODE
[3:2]
CLK_DIV
1
RST_EN
0
PRT_EN
Value
0
1
0
1
0
0
1
00
01
10
11
0
1
0
1
Description
The timer does not reach its end-of-count value. This bit is reset
to 0 every time the TMRx_CTL register is read.
The timer reaches its end-of-count value. If IRQ_EN is set to 1,
an interrupt signal is sent to the CPU. This bit remains 1 until the
TMRx_CTL register is read.
Timer interrupt requests are disabled.
Timer interrupt requests are enabled.
Reserved.
The timer operates in SINGLE PASS mode. PRT_EN (bit 0) is
reset to 0, and counting stops when the end-of-count value is
reached.
The timer operates in CONTINUOUS mode. The timer reload
value is written to the counter when the end-of-count value is
reached.
Clock ÷ 4 is the timer input source.
Clock ÷ 16 is the timer input source.
Clock ÷ 64 is the timer input source.
Clock ÷ 256 is the timer input source.
The reload and restart function is disabled.
The reload and restart function is enabled. When a 1 is written to
this bit, the values in the reload registers are loaded into the
downcounter when the timer restarts. The programmer must
ensure that this bit is set to 1 each time SINGLE-PASS mode is
used.
The programmable reload timer is disabled.
The programmable reload timer is enabled.
R
7
0
R/W
6
0
R/W
5
0
R/W
4
0
R/W
3
0
Programmable Reload Timers
Product Specification
R/W
2
0
eZ80F92/eZ80F93
R/W
1
0
R/W
0
0
82

Related parts for EZ80F92AZ020EG