ATMEGA164A-PU Atmel, ATMEGA164A-PU Datasheet - Page 305

IC MCU AVR 16K 20MHZ 40PDIP

ATMEGA164A-PU

Manufacturer Part Number
ATMEGA164A-PU
Description
IC MCU AVR 16K 20MHZ 40PDIP
Manufacturer
Atmel
Series
AVR® ATmegar
Datasheets

Specifications of ATMEGA164A-PU

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
32
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Eeprom Size
512 x 8
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
40-DIP (0.600", 15.24mm)
Controller Family/series
Atmega
No. Of I/o's
32
Eeprom Memory Size
512Byte
Ram Memory Size
1KB
Cpu Speed
20MHz
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
26.7.6
26.7.7
26.7.8
8272A–AVR–01/10
Reading the Flash
Reading the EEPROM
Programming the Fuse Low Bits
Figure 26-4. Programming the EEPROM Waveforms
The algorithm for reading the Flash memory is as follows (refer to
page 302
1. A: Load Command “0000 0010”.
2. H: Load Address Extended Byte (0x00- 0xFF).
3. G: Load Address High Byte (0x00 - 0xFF).
4. B: Load Address Low Byte (0x00 - 0xFF).
5. Set OE to “0”, and BS1 to “0”. The Flash word low byte can now be read at DATA.
6. Set BS to “1”. The Flash word high byte can now be read at DATA.
7. Set OE to “1”.
The algorithm for reading the EEPROM memory is as follows (refer to
on page 302
1. A: Load Command “0000 0011”.
2. G: Load Address High Byte (0x00 - 0xFF).
3. B: Load Address Low Byte (0x00 - 0xFF).
4. Set OE to “0”, and BS1 to “0”. The EEPROM Data byte can now be read at DATA.
5. Set OE to “1”.
The algorithm for programming the Fuse Low bits is as follows (refer to
on page 302
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Give WR a negative pulse and wait for RDY/BSY to go high.
164A/164PA/324A/324PA/644A/644PA/1284/1284P
RESET +12V
RDY/BSY
PAGEL
XTAL1
DATA
XA1
XA0
BS1
BS2
WR
OE
for details on Command and Address loading):
for details on Command and Address loading):
for details on Command and Data loading):
0x11
A
ADDR. HIGH
G
ADDR. LOW
B
DATA
C
XX
E
ADDR. LOW
B
DATA
C
K
XX
E
”Programming the Flash” on
”Programming the Flash”
”Programming the Flash”
L
305

Related parts for ATMEGA164A-PU