HD64F3644H Renesas Electronics America, HD64F3644H Datasheet - Page 359

IC H8 MCU FLASH 32K 64-QFP

HD64F3644H

Manufacturer Part Number
HD64F3644H
Description
IC H8 MCU FLASH 32K 64-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Lr
Datasheet

Specifications of HD64F3644H

Core Processor
H8/300L
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI
Peripherals
PWM, WDT
Number Of I /o
53
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
64-QFP
Package
64PQFP
Family Name
H8
Maximum Speed
8 MHz
Operating Supply Voltage
3.3|5 V
Data Bus Width
8 Bit
Number Of Programmable I/os
45
Interface Type
SCI
On-chip Adc
8-chx8-bit
Number Of Timers
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3644H
Manufacturer:
HITACHI
Quantity:
490
Part Number:
HD64F3644H
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3644H
Manufacturer:
HD
Quantity:
20 000
Company:
Part Number:
HD64F3644H
Quantity:
27
Part Number:
HD64F3644HV
Manufacturer:
Renesas
Quantity:
600
Part Number:
HD64F3644HV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3644HV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD64F3644HV/H83644
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
For further details, see section 3.3, Interrupts.
10.3.8
The following points should be noted when using SCI3.
1. Relation between writes to TDR and bit TDRE
2. Operation when a number of receive errors occur simultaneously
Table 10.17 SSR Status Flag States and Receive Data Transfer
RDRF * OER
1
0
0
1
1
0
1
Legend:
O: Receive data is transferred from RSR to RDR.
Note:
: Receive data is not transferred from RSR to RDR.
Bit TDRE in the serial status register (SSR) is a status flag that indicates that data for serial
transmission has not been prepared in TDR. When data is written to TDR, bit TDRE is cleared
to 0 automatically. When SCI3 transfers data from TDR to TSR, bit TDRE is set to 1.
Data can be written to TDR irrespective of the state of bit TDRE, but if new data is written to
TDR while bit TDRE is cleared to 0, the data previously stored in TDR will be lost of it has
not yet been transferred to TSR. Accordingly, to ensure that serial transmission is performed
dependably, you should first check that bit TDRE is set to 1, then write the transmit data to
TDR once only (not two or more times).
If a number of receive errors are detected simultaneously, the status flags in SSR will be set to
the states shown in table 10.17. If an overrun error is detected, data transfer from RSR to RDR
will not be performed, and the receive data will be lost.
SSR Status Flags
* Bit RDRF retains its state prior to data reception.
1
0
0
1
1
0
1
Application Notes
FER
0
1
0
1
0
1
1
PER
0
0
1
0
1
1
1
Receive Data Transfer
(RSR
O
O
O
RDR)
Section 10 Serial Communication Interface
Receive Error Status
Overrun error
Framing error
Parity error
Overrun error + framing error
Overrun error + parity error
Framing error + parity error
Overrun error + framing error + parity error
Rev. 6.00 Sep 12, 2006 page 337 of 526
REJ09B0326-0600

Related parts for HD64F3644H