HD64F3644PV Renesas Electronics America, HD64F3644PV Datasheet - Page 270

IC H8/3644 MCU FLASH 32K 64SDIP

HD64F3644PV

Manufacturer Part Number
HD64F3644PV
Description
IC H8/3644 MCU FLASH 32K 64SDIP
Manufacturer
Renesas Electronics America
Series
H8® H8/300Lr
Datasheet

Specifications of HD64F3644PV

Core Processor
H8/300L
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI
Peripherals
PWM, WDT
Number Of I /o
53
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
64-SDIP (0.750", 19.05mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3644PV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
HD64F3644PV
Manufacturer:
RENESAS
Quantity:
25
Section 9 Timers
Bit 5 Input Capture Flag C (ICFC): Bit 5 is a status flag that indicates that the FRC value has
been transferred to ICRC by an input capture signal. If BUFEA is set to 1 in TCRX, ICFC is set
by the input capture signal even though the FRC value is not transferred to ICRC. In buffered
operation, ICFC can accordingly be used as an external interrupt, by setting the ICICE bit to 1.
This flag is set by hardware and cleared by software. It cannot be set by software.
Bit 5: ICFC
0
1
Bit 4 Input Capture Flag D (ICFD): Bit 4 is a status flag that indicates that the FRC value has
been transferred to ICRD by an input capture signal. If BUFEB is set to 1 in TCRX, ICFD is set
by the input capture signal even though the FRC value is not transferred to ICRD. In buffered
operation, ICFD can accordingly be used as an external interrupt, by setting the ICIDE bit to 1.
This flag is set by hardware and cleared by software. It cannot be set by software.
Bit 4: ICFD
0
1
Bit 3 Output Compare Flag A (OCFA): Bit 3 is a status flag that indicates that the FRC value
has matched OCRA. This flag is set by hardware and cleared by software. It cannot be set by
software.
Bit 3: OCFA
0
1
Rev. 6.00 Sep 12, 2006 page 248 of 526
REJ09B0326-0600
Description
Clearing condition:
After reading ICFC = 1, cleared by writing 0 to ICFC
Setting condition:
Set by input capture signal
Description
Clearing condition:
After reading ICFD = 1, cleared by writing 0 to ICFD
Setting condition:
Set by input capture signal
Description
Clearing condition:
After reading OCFA = 1, cleared by writing 0 to OCFA
Setting condition:
Set when FRC matches OCRA
(initial value)
(initial value)
(initial value)