HD64F2638F20J Renesas Electronics America, HD64F2638F20J Datasheet - Page 554

IC H8S MCU FLASH 256K 128-QFP

HD64F2638F20J

Manufacturer Part Number
HD64F2638F20J
Description
IC H8S MCU FLASH 256K 128-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2638F20J

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
Motor Control PWM, POR, PWM, WDT
Number Of I /o
72
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
128-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2638F20J
Manufacturer:
PENESAS
Quantity:
252
Section 13 Serial Communication Interface (SCI)
TXI interrupt are requested simultaneously, the TXI interrupt may have priority for acceptance,
with the result that the TDRE and TEND flags are cleared. Note that the TEI interrupt will not be
accepted in this case.
13.5
The following points should be noted when using the SCI.
Relation between Writes to TDR and the TDRE Flag
The TDRE flag in SSR is a status flag that indicates that transmit data has been transferred from
TDR to TSR. When the SCI transfers data from TDR to TSR, the TDRE flag is set to 1.
Data can be written to TDR regardless of the state of the TDRE flag. However, if new data is
written to TDR when the TDRE flag is cleared to 0, the data stored in TDR will be lost since it has
not yet been transferred to TSR. It is therefore essential to check that the TDRE flag is set to 1
before writing transmit data to TDR.
Operation when Multiple Receive Errors Occur Simultaneously
If a number of receive errors occur at the same time, the state of the status flags in SSR is as
shown in table 13-14. If there is an overrun error, data is not transferred from RSR to RDR, and
the receive data is lost.
Table 13-13 State of SSR Status Flags and Transfer of Receive Data
RDRF
1
0
0
1
1
0
1
Notes:
Page 504 of 1458
X: Receive data is not transferred from RSR to RDR.
SSR Status Flags
ORER
1
0
0
1
1
0
1
Usage Notes
: Receive data is transferred from RSR to RDR.
FER
0
1
0
1
0
1
1
PER
0
0
1
0
1
1
1
Receive Data Transfer
RSR to RDR
X
X
X
X
Overrun error
Overrun error + framing error
Overrun error + parity error
Overrun error + framing error +
Receive Error Status
Framing error
Parity error
Framing error + parity error
parity error
H8S/2639, H8S/2638, H8S/2636,
REJ09B0103-0800 Rev. 8.00
H8S/2630, H8S/2635 Group
May 28, 2010

Related parts for HD64F2638F20J