HD64F2638F20J Renesas Electronics America, HD64F2638F20J Datasheet - Page 710

IC H8S MCU FLASH 256K 128-QFP

HD64F2638F20J

Manufacturer Part Number
HD64F2638F20J
Description
IC H8S MCU FLASH 256K 128-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2638F20J

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
Motor Control PWM, POR, PWM, WDT
Number Of I /o
72
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
128-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2638F20J
Manufacturer:
PENESAS
Quantity:
252
Section 16 Controller Area Network (HCAN)
• Mailbox transmit/receive settings
• Mailbox (RAM) initialization
• Message transmission method setting
Page 660 of 1458
Mailbox transmit/receive settings should be made in advance. A total of 30 mailbox can be set
for transmission or reception (mailboxes 1 to 15 in HCAN0 and HCAN1). To set a mailbox for
transmission, clear the corresponding bit to 0 in the mailbox configuration register (MBCR).
Refer to Mailbox Transmit/Receive Settings in 16.3.2, Initialization after Hardware Reset, for
details.
As message control/data registers (MCx[x], MDx[x]) are configured in RAM, their initial
values after powering on are undefined, and so bit initialization is necessary. Write 0s or 1s to
the mailboxes. See Mailbox (Message Control/Data (MCx[x], MDx[x]) Initial Setting in
16.3.2, Initialization after a Hardware Reset, for details.
Set the transmission method for mailboxes designated for transmission. The following two
transmission methods can be used. Refer to Message Transmission Method Setting in 16.3.2,
Initialization after Hardware Reset, for details.
a. Transmission order determined by message identifier priority
b. Transmission order determined by mailbox number priority
H8S/2639, H8S/2638, H8S/2636,
REJ09B0103-0800 Rev. 8.00
H8S/2630, H8S/2635 Group
May 28, 2010