ST62T25CM6/TR STMicroelectronics, ST62T25CM6/TR Datasheet - Page 79

IC MCU 8BIT W/ADC 28-SOIC

ST62T25CM6/TR

Manufacturer Part Number
ST62T25CM6/TR
Description
IC MCU 8BIT W/ADC 28-SOIC
Manufacturer
STMicroelectronics
Series
ST6r
Datasheet

Specifications of ST62T25CM6/TR

Core Processor
ST6
Core Size
8-Bit
Speed
8MHz
Peripherals
LVD, POR, WDT
Number Of I /o
20
Program Memory Size
4KB (4K x 8)
Program Memory Type
OTP
Ram Size
64 x 8
Voltage - Supply (vcc/vdd)
3 V ~ 6 V
Data Converters
A/D 16x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
28-SOIC (7.5mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Connectivity
-
EMC CHARACTERISTICS (Cont’d)
11.7.2 Absolute Electrical Sensitivity
Based on three different tests (ESD, LU and DLU)
using specific measurement methods, the product
is stressed in order to determine its performance in
terms of electrical sensitivity. For more details, re-
fer to the AN1181 application note.
11.7.2.1 Electro-Static Discharge (ESD)
Electro-Static Discharges (3 positive then 3 nega-
tive pulses separated by 1 second) are applied to
the pins of each sample according to each pin
combination. The sample size depends of the
number of supply pins of the device (3 parts*(n+1)
supply pin). Two models are usually simulated:
Human Body Model and Machine Model. This test
conforms to the JESD22-A114A/A115A standard.
See
Human Body Model Test Sequence
– C
Absolute Maximum Ratings
Notes:
1. Data based on characterization results, not tested in production.
Figure 57. Typical Equivalent ESD Circuits
ator.
V
HIGH VOLTAGE
V
GENERATOR
Symbol
ESD(HBM)
L
ESD(MM)
Figure 57
is loaded through S1 by the HV pulse gener-
PULSE
Electro-static discharge voltage
(Human Body Model)
Electro-static discharge voltage
(Machine Model)
and the following test sequences.
S1
C
L
100pF
HUMAN BODY MODEL
Ratings
R=1500
ST6
T
T
A
A
S2
+25°C
+25°C
– S1 switches position from generator to R.
– A discharge from C
– S2 must be closed 10 to 100ms after the pulse
Machine Model Test Sequence
– C
– S1 switches position from generator to ST6.
– A discharge from C
– S2 must be closed 10 to 100ms after the pulse
– R (machine resistance), in series with S2, en-
to the ST6 occurs.
delivery period to ensure the ST6 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
ator.
delivery period to ensure the ST6 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
sures a slow discharge of the ST6.
HIGH VOLTAGE
GENERATOR
L
is loaded through S1 by the HV pulse gener-
Conditions
PULSE
ST6215CM-Auto ST6225CM-Auto
L
S1
L
through R (body resistance)
to the ST6 occurs.
C
L
200pF
Maximum value
MACHINE MODEL
ST6
2000
200
1)
79/100
Unit
V
S2
1

Related parts for ST62T25CM6/TR