Specifications of MMC2107CFCPV33

Core Processor
M210
Core Size
32-Bit
Speed
33MHz
Connectivity
EBI/EMI, SCI, SPI
Peripherals
POR, PWM, WDT
Number Of I /o
72
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
144-LQFP
Data Bus Width
32 bit
Data Ram Size
8 KB
Interface Type
SCI, SPI
Maximum Clock Frequency
33 MHz
Number Of Programmable I/os
32
Number Of Timers
4 bit
Operating Supply Voltage
0 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Lead Free Status / Rohs Status
No RoHS Version Available

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MMC2107CFCPV33
Manufacturer:
AMD
Quantity:
1 001
Part Number:
MMC2107CFCPV33
Manufacturer:
MOTOLOLA
Quantity:
745
Part Number:
MMC2107CFCPV33
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MMC2107CFCPV33
Manufacturer:
MOT
Quantity:
2
Part Number:
MMC2107CFCPV33
Manufacturer:
FREESCALE
Quantity:
20 000
Serial Communications Interface Modules (SCI1 and SCI2)
Technical Data
358
NOTE:
Serial Communications Interface Modules (SCI1 and SCI2)
To verify the start bit and to detect noise, data recovery logic takes
samples at RT3, RT5, and RT7.
If start bit verification is not successful, the RT clock is reset and a new
search for a start bit begins.
To determine the value of a data bit and to detect noise, recovery logic
takes samples at RT8, RT9, and RT10.
The RT8, RT9, and RT10 data samples do not affect start bit verification.
If any or all of the RT8, RT9, and RT10 samples are logic 1s following a
successful start bit verification, the NF flag is set and the receiver
interprets the bit as a start bit (logic 0).
RT8, RT9, and RT10 Samples
Freescale Semiconductor, Inc.
RT3, RT5, and RT7 Samples
For More Information On This Product,
Go to: www.freescale.com
000
001
010
011
100
101
110
111
000
001
010
011
100
101
110
111
Table 16-6. Start Bit Verification
Table 16-7. Data Bit Recovery
Data Bit Determination
Start Bit Verification
0
0
0
1
0
1
1
1
Yes
Yes
Yes
Yes
No
No
No
No
MMC2107 – Rev. 2.0
Noise Flag
Noise Flag
MOTOROLA
0
1
1
1
1
1
1
0
0
1
1
0
1
0
0
0