C8051F320 Silicon Laboratories Inc, C8051F320 Datasheet - Page 246

no-image

C8051F320

Manufacturer Part Number
C8051F320
Description
IC 8051 MCU 16K FLASH 32LQFP
Manufacturer
Silicon Laboratories Inc
Series
C8051F32xr
Datasheet

Specifications of C8051F320

Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
SMBus (2-Wire/I²C), SPI, UART/USART, USB
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
25
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
2.25K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 17x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
32-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F320
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051F320
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
C8051F320-GQ
Manufacturer:
SiliconL
Quantity:
18 793
Part Number:
C8051F320-GQ
Manufacturer:
SILICON
Quantity:
1
Part Number:
C8051F320-GQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051F320-GQR
Manufacturer:
SiliconL
Quantity:
1 000
Part Number:
C8051F320-GQR
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
C8051F320-GQR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
C8051F320DK
Manufacturer:
SiliconL
Quantity:
4
Part Number:
C8051F320R
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
C8051F320/1
20.3. Watchdog Timer Mode
A programmable watchdog timer (WDT) function is available through the PCA Module 4. The WDT is used to gen-
erate a reset if the time between writes to the WDT update register (PCA0CPH4) exceed a specified limit. The WDT
can be configured and enabled/disabled as needed by software.
With the WDTE and/or WDLCK bits set to ‘1’ in the PCA0MD register, Module 4 operates as a watchdog timer
(WDT). The Module 4 high byte is compared to the PCA counter high byte; the Module 4 low byte holds the offset to
be used when WDT updates are performed. The Watchdog Timer is enabled on reset. Writes to some PCA regis-
ters are restricted while the Watchdog Timer is enabled.
20.3.1. Watchdog Timer Operation
While the WDT is enabled:
While the WDT is enabled, writes to the CR bit will not change the PCA counter state; the counter will run until the
WDT is disabled. The PCA counter run control (CR) will read zero if the WDT is enabled but user software has not
enabled the PCA counter. If a match occurs between PCA0CPH4 and PCA0H while the WDT is enabled, a reset will
be generated. To prevent a WDT reset, the WDT may be updated with a write of any value to PCA0CPH4. Upon a
PCA0CPH4 write, PCA0H plus the offset held in PCA0CPL4 is loaded into PCA0CPH4 (See Figure 20.10).
246
PCA counter is forced on.
Writes to PCA0L and PCA0H are not allowed.
PCA clock source bits (CPS2-CPS0) are frozen.
PCA Idle control bit (CIDL) is frozen.
Module 4 is forced into Watchdog Timer mode.
Writes to the Module 4 mode register (PCA0CPM4) are disabled.
PCA0CPL4
C
D
L
I
W
D
T
E
PCA0MD
W
D
C
L
K
Figure 20.10. PCA Module 4 with Watchdog Timer Enabled
PCA0CPH4
C
P
S
2
Write to
C
P
S
1
C
P
S
0
E
C
F
8-bit Adder
Enable
Adder
Enable
Rev. 1.1
PCA0CPH4
Comparator
PCA0H
8-bit
Match
PCA0L Overflow
Reset

Related parts for C8051F320