CM450DX-24S Powerex Inc, CM450DX-24S Datasheet
CM450DX-24S
Specifications of CM450DX-24S
Available stocks
Related parts for CM450DX-24S
CM450DX-24S Summary of contents
Page 1
... Applications: £ AC Motor Control £ Motion/Servo Control £ Photovoltaic/Fuel Cell Ordering Information: Example: Select the complete module number you desire from the table below -i.e. CM450DX-24S is a 1200V (V 450 Ampere Dual IGBTMOD™ Power Module. Type Current Rating V Amperes Volts (x 50) ...
Page 2
... ISO V CES V GES CRM P tot = 25°C) *1,* ERM ) does not exceed T rating. j j(max) ) rating. j(max) CM450DX-24S Units +175 °C -40 to 150 °C -40 to 125 °C 31 in-lb 40 in-lb 330 Grams 2500 V rms 1200 Volts ±20 Volts 450 Amperes 900 Amperes 3400 Watts 450 ...
Page 3
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com CM450DX-24S Dual IGBTMOD™ NX-S Series Module 450 Amperes/1200 Volts Electrical and Mechanical Characteristics, T Inverter Sector Characteristics Collector Cutoff Current Gate Leakage Current Gate-Emitter Threshold Voltage Collector-Emitter Saturation Voltage Collector-Emitter Saturation Voltage ...
Page 4
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com CM450DX-24S Dual IGBTMOD™ NX-S Series Module 450 Amperes/1200 Volts NTC Thermistor Sector 25°C unless otherwise specified j Characteristics Zero Power Resistance Deviation of Resistance B Constant Power Dissipation Module 25°C unless otherwise specified ...
Page 5
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com CM450DX-24S Dual IGBTMOD™ NX-S Series Module 450 Amperes/1200 Volts OUTPUT CHARACTERISTICS (INVERTER PART - TYPICAL) 900 T = 25° 800 20V 13.5 12 700 600 11 500 400 10 300 200 9 100 COLLECTOR-EMITTER VOLTAGE, V ...
Page 6
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com CM450DX-24S Dual IGBTMOD™ NX-S Series Module 450 Amperes/1200 Volts SWITCHING LOSS VS. COLLECTOR CURRENT (INVERTER PART - TYPICAL 600V ±15V 1. 150° 50nH Inductive Load off COLLECTOR CURRENT (AMPERES) C REVERSE RECOVERY SWITCHING LOSS VS. ...