CX-0905C CUI Inc, CX-0905C Datasheet - Page 3

BUZZER MAG 2.73KHZ 5VDC 9.6MM

CX-0905C

Manufacturer Part Number
CX-0905C
Description
BUZZER MAG 2.73KHZ 5VDC 9.6MM
Manufacturer
CUI Inc
Series
CXr
Type
Magnetic Indicator, Internal Driver
Datasheet

Specifications of CX-0905C

Frequency
2.73kHz
Voltage - Rated
5VDC
Current Rating
35mA
Size / Dimension
Circular - 9.6mm Dia x 5mm H
Mounting Type
Through Hole
Sound Pressure Level
80dB
Operating Mode
Continuous
Voltage Range
4 ~ 7VDC
Termination
Solder Pins/Posts
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Capacitance @ Frequency
-
Other names
102-1285
Environment Test
Item
High temp. test
Low temp. test
Thermal shock
Temp./Humidity cycle
Mechanical Characteristics
Item
Solderability
Soldering Heat Resistance
Terminal Mechanical Strength
Vibration
Drop Test
Phone: 800.275.4899
Fax: 503.612.2381
Test Condition
The part will be subjected to +85°C for
96 hours.
The part will be subjected to -40°C for
96 hours
The part will be subjected to 10 cycles. One
cycle will consist of:
The part shall be subjected to 10 cycles. One
cycle will last for 24 hours and consist of:
Test Condition
Lead terminals are immersed in solder bath
of 270 ±5°C for 3 ±1 seconds.
Lead terminals are immersed up to 1.5mm from
the buzzer’s body in a solder bath of 260 ±5°C
for 3 ±1 seconds.
For 10 seconds, the force of 9.8N (1.0kg) is
applied to each terminal in axial direction.
The buzzer shall be measured after applying
a vibration amplitude of 1.5 mm with 10 to
55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours.
The part will be dropped from a height of
75 cm onto a 40 mm thick wooden board 3
times in 3 axes (X, Y, Z) for a total of 9 drops.
Part No: CX-0905C
Description: magnetic buzzer
www.cui.com
20050 SW 112th Ave.
Evaluation Standard
Evaluation Standard
95% of the surface of the lead
pads must be wet with solder.
No interference in operation.
No damage or cutting off.
After the test, the part shall meet
specifications without any
damage to the appearance or
performance. The SPL should be
within ±10 dBA of the initial SPL
measurement.
After the test, the part shall meet
specifications without any
damage to the appearance or
performance. After 4 hours at
25°C, the SPL should be within
±10 dBA of the initial SPL
measurement.
Tualatin, OR 97062
Date: 9/22/2006
Unit: mm
Page No: 3 of 4

Related parts for CX-0905C