Axis
X, Y, Z
Acceleration Range
±2.3g, 9.2g
Sensitivity
18mg/digit, 72mg/digit
Voltage - Supply
2.16 V ~ 3.6 V
Output Type
Digital
Bandwidth
100Hz ~ 400Hz Selectable
Interface
I²C, SPI
Mounting Type
Surface Mount
Package / Case
16-LGA
Sensing Axis
X, Y, Z
Acceleration
2 g, 8 g
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
For Use With
497-10048 - BOARD EVAL ACCELEROMETER497-8719 - DEMO BOARD BASED ON LIS331DL497-8205 - BOARD EVALUATION LIS331AL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-8327-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LIS331DLTR
Manufacturer:
ST
Quantity:
8 270
Part Number:
LIS331DLTR
Manufacturer:
INF
Quantity:
3 000
Part Number:
LIS331DLTR
Manufacturer:
ST
0
Part Number:
LIS331DLTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
LIS331DLTR 4000/ 10+
Manufacturer:
ST
0
Part Number:
LIS331DLTR 4000/ 10+
Manufacturer:
ST
0
Part Number:
LIS331DLTR-CDW
Manufacturer:
SHARP
Quantity:
11 470
Register description
7
7.1
7.2
26/42
Register description
The device contains a set of registers which are used to control its behavior and to retrieve
acceleration data. The registers address, made of 7 bits, is used to identify them and to
write the data through serial interface.
WHO_AM_I (0Fh)
Table 16.
Device identification register.
This register contains the device identifier that for LIS331DL is set to 3Bh.
CTRL_REG1 (20h)
Table 17.
Table 18.
DR bit allows to select the data rate at which acceleration samples are produced. The
default value is 0 which corresponds to a data-rate of 100 Hz. By changing the content of
DR to “1” the selected data-rate will be set equal to 400 Hz.
PD bit allows to turn the device out of power-down mode. The device is in power-down
mode when PD= ‘0’ (default value after boot). The device is in normal mode when PD is set
to ‘1’.
STP, STM bits are used to activate the self test function. When the bit is set to one, an
output change will occur to the device outputs (refer to
allowing to check the functionality of the whole measurement chain.
DR
PD
FS
STP, STM
Zen
Yen
Xen
DR
0
WHO_AM_I register
CTRL_REG1 register
CTRL_REG1 description
Data rate selection. Default value: 0
(0: 100 Hz output data rate; 1: 400 Hz output data rate)
Power Down Control. Default value: 0
(0: power down mode; 1: active mode)
Full Scale selection. Default value: 0
(refer to
Self Test Enable. Default value: 0
(0: normal mode; 1: self test P, M enabled)
Z axis enable. Default value: 1
(0: Z axis disabled; 1: Z axis enabled)
Y axis enable. Default value: 1
(0: Y axis disabled; 1: Y axis enabled)
X axis enable. Default value: 1
(0: X axis disabled; 1: X axis enabled)
PD
0
Table 3
FS
for typical full scale values)
1
STP
1
STM
1
Table 3
Zen
0
and
4
for specifications) thus
Yen
1
LIS331DL
Xen
1