... High Voltage Instrumentation Amplifier GENERAL DESCRIPTION The AD202 and AD204 are general purpose, two-port, trans- former-coupled isolation amplifiers that may be used in a broad range of applications where input signals must be measured, processed, and/or transmitted without a galvanic connection. These industry standard isolation amplifiers offer a complete isolation function, with both signal and power isolation provided for in a single compact plastic SIP or DIP style package ...
Page 2
AD202/AD204–SPECIFICATIONS Model GAIN Range Error vs. Temperature vs. Time vs. Supply Voltage 1 Nonlinearity ( V/V) Nonlinearity vs. Isolated Supply Load INPUT VOLTAGE RATINGS Input Voltage Range Max lsolation Voltage (Input to Output) AC, 60 Hz, Continuous Continuous ...
Page 3
... AD202KY AD202JN AD202KN AD204JY AD204KY AD204JN AD204KN CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the AD202/AD204 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges ...
Page 4
AD202/AD204 DIFFERENCES BETWEEN THE AD202 AND AD204 The primary distinction between the AD202 and AD204 is in the method by which they are powered: the AD202 operates directly from while the AD204 is powered by a non- ...
Page 5
AD246 Clock Driver. The AD246 is a compact, inexpensive clock driver that can be used to obtain the required clock from a single 15 V supply. Alternatively, the circuit shown in Figure 4 (essentially an AD246) can be used. In ...
Page 6
AD202/AD204 Adjustments. When gain and zero adjustments are needed, the circuit details will depend on whether adjustments are to be made at the isolator input or output, and (for input adjustments) on the input circuit used. Adjustments are usually best ...
Page 7
FREQUENCY – Hz Figure 10b. AD202 Dynamics and Noise. Frequency response plots for the AD202 and AD204 are given in Figure 11. Since neither isolator is ...
Page 8
AD202/AD204 Using Isolated Power. Both the AD202 and the AD204 provide ±7.5 V power outputs referenced to input common. These may be used to power various accessory circuits that must operate at the input common-mode level; the input zero adjustment ...
Page 9
CHANNEL 0 CHANNEL 0.1” GRID 100pF Figure 16b. Synchronization. Since AD204s operate from a common clock, synchronization is inherent. AD202s will ...
Page 10
AD202/AD204 High Compliance Current Source. In Figure 19, an isolator is used to sense the voltage across current-sensing resistor R allow direct feedback control of a high voltage transistor or FET used as a high compliance current source. Since the ...
Page 11
AD202/AD204 SIP Package 2.08 (52.8) MAX AD202/AD204 FRONT VIEW 0.20 (5.1) 0.15 (3.81) TYP BOTTOM VIEW 0.05 (1.3)TYP 1.30 (33.0) 0.143 (3.63) NOTE: PIN 31 IS PRESENT ONLY ON AD202 ...
Page 12
AD202/AD204 Revision History Location 10/02—Data Sheet changed from REV REV. D. Deleted FUNCTIONAL BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . ...