RPM21ED SQUARE D, RPM21ED Datasheet - Page 22

INTERFACE RELAY, DPDT, 48VDC, 2600OHM

RPM21ED

Manufacturer Part Number
RPM21ED
Description
INTERFACE RELAY, DPDT, 48VDC, 2600OHM
Manufacturer
SQUARE D
Datasheet

Specifications of RPM21ED

Coil Voltage Vdc Nom
48V
Contact Current Max
15A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Max
250V
Coil Resistance
2600ohm
Contact Configuration
DPDT
Relay Mounting
Plug In
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DC Control Relays
Table 23.105: DC Control Relays
DC Control Relay Utility Auxiliary Relay
Table 23.106: Dimensions
DC Timing Relays
Table 23.107: DC Timing Relays
Table 23.108: DC Contact Ratings (for AC ratings, see page 23-21)
23-22
Industrial Relays
Square D
Note: Do not use any 8501 Type XC4 Master Cartridges on any DC-operated device.
Normally Open Convertible
Instantaneous Contacts
Type XDO40XTE2
Timing
Mode
On
Delay
Off
Delay
Type of
Cartridge
Standard
Overlapping
Logic Reed
Timing Relay
Control Relay
Type XDO40
B30080-066
Normally
Open Convertible
Instantaneous
Contacts
A
B30080-075 A
Volts
®
7.77
197
125
250
125
NEMA Style
0
2
4
0
2
4
0
2
4
6
8
NEMA
Rating
P600
P150
3.56
90 3.12
Prov. for
(2) #8/#10 Mtg. Screws
.25
79
6
Easily convertible On Delay or Off Delay.
Two adjustable timing ranges.
Repeat accuracy well above ±10%.
Convertible 1 N.O. and 1 N.C. timed contacts.
Large knob for easy adjustment of time delay.
Off Delay mode times out even after loss of power.
Make and Break
Amperes
138 VA Max.
Replaceable, highly reliable pure DC power plant: no
economizing resistors, overlapping contacts or dual-
wound coil.
Utilizes the same Type XB adder decks and
attachments as the AC version.
Offers all the features of the AC relay.
Available in up to 8 poles.
All contact poles are usable since no overlapping
contacts are needed.
1.12
N.O.
28
30 Vdc, 60 ma
Convertible
2.23
Contacts
1
1
1
1
1
1
57
Timed
3.56
90 3.12
(2) #8/#10 Mtg. Screws
Inductive
0.55
Prov. for
1.1
1.1
.25
79
6
N.C.
1
1
1
1
1
1
1.12
No. of Poles
28
DC Ratings
2.23
57
10–12
XDO00XTE1 e
XDO20XTE1 e
XDO40XTE1 e
XDO00XTD1 e
XDO20XTD1 e
XDO40XTD1 e
0–4
6–8
Continuous
Amperes
XDO00e
XDO20e
XDO40e
XDO60e
XDO80e
0.2–60 s
Type
Type
5
5
5
Timing Relay
Control Relay
5.17
6.37
7.60
in.
Dim. A
Make and
Break
Amperes
XDO00XTD2 e
XDO20XTD2 e
XDO40XTD2 e
XDO00XTE2 e
XDO20XTE2 e
XDO40XTE2 e
mm
131
162
193
0.8
5–180 s
4
4
Type
Resistive
Shipping Weight
Continuous
Amperes
3.1
3.4
3.8
lb.
5
5
5
$ Price
$ Price
656.00
714.00
769.00
656.00
714.00
769.00
257.00
314.00
372.00
427.00
485.00
CP1
Discount
Schedule
DC Latching Relays
Table 23.109: DC Latching Relays
Note: Unlatch coil is rated for intermittent duty and should be connected through a N.O. contact
DC Utility Relays
Table 23.111: DC Utility Relays
Table 23.112: Average Operating Times (in ms)
Table 23.113: Voltage Codes—8501 XUDO and XDO Relays
Table 23.114: How to Order
For Replacement coils, see page 23-23
For UL and CSA approvals, see page 23-21
Normally Open Convertible
Instantaneous Contacts
Device
DC Relay
DC Latching Relay
To Order Specify:
Type XDO40XDL
e
8501 XUDO Relays ONLY
Latching Relay
Type XUDO40
Class Number
Type Number
Voltage Code
Class 8501 / Refer to Catalog 8501CT9601
Utility Relay
of the relay if the input signal is maintained. Order one more N.O. contact than the
application requires to use as a coil clearing contact.
Voltage code must be specified to order these products. Refer to Table 23.113 and insert
the appropriate code as shown in Table 23.114: How to Order.
DC Voltages for
Number of Convertible Contacts
B30080-159
N.O.
12
4
0
8
0
0
125
250
12
24
48
A
6
2
4
6
8
Ideal for utility plant applications where reliable
performance and a pure DC power plant is required. In
addition to the Type XDO relay features, the Type
XUDO provides:
Up to 12 poles N.O. or N.C.
Nominal 125 Vdc coil, capable of handling 140 Vdc
continuously and picking up at 105 Vdc after having
been operated at 140 Vdc continuously. Other voltages
with comparable operating characteristics are
available.
Enclosed device capable of operating in 145°F
ambient.
Pick-Up
37
37
Mechanical latch holds all contacts switched even
after removal of power from replaceable latching coil.
Provides sequence memory in the event of power
loss.
Ideal for sequencing applications such as press
control, process control and punch presses.
Replaceable unlatch coil to switch contacts back to
original state.
3.56
90
(2) #8/#10 Mtg. Screws
Prov. for
Type X
N.C.
Code
3.12
.25
79
V50
V51
V53
V56
V63
V67
6
12
0
4
0
8
0
1.12
Class
28
8501
2.23
57
XDO20XDL e
XDO40XDL e
XDO60XDL e
XDO80XDL e
®
8501 XDO Relays
Relays
DC Voltages for
Type
Table 23.110: Dimensions
No. of
Poles
Catalog Number
XDO40
115/125
230/250
Type
2–4
6–8
XUDO1200 e
XUDO0012 e
XUDO40 e
XUDO04 e
XUDO80 e
XUDO08 e
6
12
24
32
48
72
90
Drop-Out
21
45
Latching Relay
Type
7.76
8.98
in.
Voltage Code
Dim. A
www.schneider-electric.us
Open Type
© 2009 Schneider Electric
V53
mm
197
228
Code
All Rights Reserved
V50
V51
V53
V54
V56
V58
V59
V62
V66
Weight, lb.
Shipping
3.9
4.2
$ Price
$ Price
567.00
634.50
691.50
747.00
464.00
606.00
747.00